The purpose of this study was to evaluate the five-year clinical performance of a two-step self-etch adhesive in non-carious cervical sclerotic lesions with or without selective acid-etching of enamel margins. A total of 104 cervical restorations in 22 patients (46-64 years) were bonded following either self-etch approach (AdheSE non-etch) or a similar application, including selective acid-etching of enamel margins (AdheSE etch), and were restored with resin composite. The restorations were evaluated at baseline and after one, two, three and five-years (84 restorations in 19 patients) according to the USPHS criteria.
View Article and Find Full Text PDFScientificWorldJournal
December 2014
The purpose of this study was to evaluate the influence of prophylactic polishing pastes (PPP; Detartrine (DT), Topex (TP)) on surface roughness (R(a)) of indirect composites (IRC; Tescera (TES), Gradia (GRD), and Estenia C&B (EST)), a glass ceramic (Empress 2 layering (E2)), and a leucite reinforced glass ceramic (Empress Esthetic (EE)) with two different (glazed (G); polished (P)) surface preparations. A total of 90 IRC and 120 ceramic discs, 8 mm in diameter and 2 mm thick, were prepared. E2 and EE specimens were randomly divided into two groups (n = 30).
View Article and Find Full Text PDFObjective: The purpose of this prospective, controlled, randomized study was to evaluate the 3-year clinical performance of a two-step self-etch adhesive (AdheSE, Ivoclar Vivadent; Schaan, Liechtenstein) in non-carious cervical sclerotic lesions with or without selective acid-etching of the enamel margins.
Material And Methods: Twenty-two patients (mean age 51.5) having at least two pairs of non-carious cervical sclerotic erosion⁄attrition⁄abfraction lesions with incisal or occlusal margins in the enamel and gingival margins in the dentin were included in the study.
Objective: To investigate the effect of a prophylaxis paste on surface roughness of different composites, enamel, dentin and porcelain surfaces.
Methods: Three different composites (FiltekZ250/Group1, Filtek Supreme XT/Group2, Premise/Group3), enamel/Group4, dentin/Group5 and porcelain/Group6 samples were used in this study. All specimens were prepared flat by SiC discs and polished with a diamond polishing paste.
This study evaluated the effect of a high-concentration carbamide peroxide–containing home bleaching system (Opalescence PF) and a hydrogen peroxide–containing over-the-counter bleaching system (Treswhite Supreme) on the microhardness of two nanocomposites (Filtek Supreme XT and Premise) and leucite-reinforced glass ceramic (Empress Esthetic), glass ceramic (Empress 2 layering), and feldspathic porcelain (Matchmaker MC). A total of 100 specimens, 20 of each kind of the restorative materials, 2 mm in thickness and 10 mm in diameter, were fabricated. Then the specimens were polished with SiC paper and 1 μm alumina polishing paste.
View Article and Find Full Text PDFObjective: The purpose of this study was to evaluate the influence of Er:YAG laser irradiation on shear-bond strength of self-adhesive resin cements to dentin.
Background Data: Different laser-irradiation settings are used for dentin-surface pretreatment, which may affect the bond strength of resins.
Methods: Fourty-five extracted third molars were selected, sectioned in a mesiodistal direction, and 90 tooth slabs were obtained.
Introduction: The purpose of this study was to evaluate the microtensile bond strength of a total etch (XP-Bond) and a self-etch (Clearfil SE Bond) adhesive system to dentine surfaces treated using endodontic irrigants.
Methods: Twenty-four freshly extracted third molars were used. After creating a smear layer on the coronal midthird portion of the crowns, the teeth were divided into three groups and surfaces were irrigated with distilled water, 5.
Objective: The purpose of this study was to investigate the clinical performance of high-strength glass ionomer cement (HSGIC) and resin-modified glass ionomer (RMGIC) in single and multiple surface carious cavities in the field conditions.
Material And Methods: A split-mouth design, including ninety-one fillings placed on contra lateral molar pairs of 37 children, was used in permanent dentition. As filling materials, a HSGIC (Ketac Molar/3M ESPE) and a RMGIC (Vitremer/ 3M ESPE) were used with the Atraumatic Restorative Treatment (ART).
This study evaluated the effects of fiber nets and application techniques and flowable composites as a liner on microleakage and the effects of fiber nets on polymerization shrinkage in Class II MOD cavities. Standard MOD cavities were performed in 80 extracted third molars. The teeth were randomly divided into eight groups (n=10).
View Article and Find Full Text PDFPurpose: To evaluate acid-etching effects prior to the application of self-etching primer and the effect of different primer application techniques on dentin shear bond strength (SBS).
Materials And Methods: Forty human third molar cervical regions were used in this study. The teeth were randomly divided into four groups (n=10) of different tooth surface conditions: group A: Clearfil Protect Primer applied gently (inactive) + Clearfil Protect Bond; group B: 38% phosphoric acid for 15 s, rinsed 15 s, and dried 15 s + Clearfil Protect Primer applied gently (inactive) + Clearfil Protect Bond; group C: Clearfil Protect Primer applied with agitation by microapplicator brush (active) + Clearfil Protect Bond; group D: 38% phosphoric acid for 15 s, rinsed 15 s, and dried 15 s + Clearfil Protect Primer applied with agitation by microapplicator brush (active) + Clearfil Protect Bond.
Thirty-five (case 1), 15 (case 2) and 22 (case 3)-year-old female patients presented to Yeditepe University Dental Faculty Clinic because of esthetic reasons. Fractures of maxillar central incisors including enamel and dentin were diagnosed. Beveling with diamond bur was performed in all four cases.
View Article and Find Full Text PDFThe two-fold aims of this study were: (1) to evaluate the microtensile bond strengths of different adhesive systems to sclerotic and sound palatal dentin; and (2) to observe the respective resin-dentin interfaces. Thirty extracted human incisor teeth were divided into two groups. Group I comprised sclerotic defects in the palatal zone.
View Article and Find Full Text PDFAm J Orthod Dentofacial Orthop
August 2006
Introduction: In this study, we investigated ultramorphology, surface roughness, and microhardness of permanent and deciduous tooth enamel after various stripping methods.
Methods: One hundred twenty deciduous and permanent teeth (n = 60 each) were used. Qualitative (scanning electron microscopy) and quantitative (surface roughness and microhardness tests) experiments were carried out in the following experimental groups: group 1, stripping disk; group 2, diamond-coated metal strip; group 3, stripping disk and Sof-Lex discs (3M-ESPE, Seefeld, Germany); group 4, diamond-coated metal strip and Sof-Lex discs; group 5 (chemical stripping), 37% orthophosphoric acid in conjunction with diamond-coated metal strip; group 6 (control), no stripping.
Objective: The purpose of this study was to evaluate the two year clinical performance of posterior composite restorations in endodontically treated premolars and molars using a hybrid composite (Filtek Z-250, 3M ESPE) and a total etch bonding system (Single Bond, 3M ESPE).
Method And Materials: Thirty-nine class II restorations in endodontically treated premolars (n=11) and molars (n=28) of 27 patients (14 female, 13 male, mean age 36.51) in 16 maxillar and 23 mandibular teeth were placed by one operator.
Objective: The purpose of this study was to evaluate the effect of a filled adhesive (One-Step Plus; Bisco) versus an unfilled adhesive (One-Step; Bisco) on the microtensile bond strength (muTBS) to dentin using total-etch (Uni-etch; Bisco) and self-etch (Tyrian SPE; Bisco) techniques.
Methods: Twenty extracted human third molars were ground flat to expose occlusal dentin. After the dentin surfaces were polished with 600-grit SiC paper, the teeth were randomly assigned to four groups according to the bonding agent and technique being used.
Objectives: The aim of this study was to assess the feasibility of the resin-modified glass ionomer (RMGI) material in atraumatic restorative treatment (ART) approach and compare RMGI with the high-strength traditional glass ionomer cement (GIC) in permanent teeth with one or more surface-carious cavities.
Materials And Methods: This study was conducted in a village school in rural southeastern Anatolia, Turkey. The RMGI and GIC restorations with the ART technique were placed randomly employing a split mouth design.
This study aimed to evaluate the microtensile bond strength (microTBS) of photo- and dual-cure adhesives to sound and caries-affected dentin using total- and self-etch techniques. Human third molars with occlusal caries were prepared as previously described by Nakajima and others (1995). Dentin surfaces were bonded with Optibond Solo Plus (Kerr; photo-cure adhesive) or Optibond Solo Plus + Dual-cure activator (Kerr; dual-cure adhesive) with total- and self-etch technique.
View Article and Find Full Text PDFThe purpose of this study was to determine the flexural strength (FS), flexural modulus (FM), depth of cure (DC), polymerization shrinkage (PS), and microhardness (VH) of the following composites: Two packable composites--Filtek P-60 and Solitaire 2; One ion-releasing composite--riston AT; and Two hybrid composites--Charisma and Filtek Z-250. Data of the different tests conducted were obtained as follows: FS and FM data were determined with a universal-testing machine; Polymerization shrinkage was determined using the apparatus of Watts and Cash; Depth of cure was measured with a micrometer (Mitotuyo, UK); and Microhardness was measured with a Shimadzu Microhardness tester (500 g, 15 seconds). All data of the different tests were statistically analyzed by one-way variance analysis (ANOVA), which yielded the following results: Filtek Z-250 showed the statistically highest flexural strength and modulus values.
View Article and Find Full Text PDFObjective: To evaluate the effect of two cavity disinfectants, a 2% chlorhexidine and a 1% benzalkonium chloride solution, on the shear and tensile bond strengths of dentin bonding systems to dentin.
Method And Materials: Superficial dentin was exposed from 84 freshly extracted human third molars. The teeth were randomly assigned to two main groups according to the bonding agent used, either One Step or Optibond Solo.