Publications by authors named "Moucka L"

This paper presents a statistical model for estimating probability, which states that a quality of radon measurements using the electret ion chamber system RM-1 will be accurate. The quality of the electret measurement was modelled as a ratio between the reference radon concentration and values measured under real conditions with varied levels of indoor radon concentration and microclimate indoor conditions. It was stated that the accuracy tolerance of measured values is 20 % of the given reference value.

View Article and Find Full Text PDF

Two new single-family houses identified as insufficient with regard to existing radon barrier efficiency, have been selected for further examination. A complex set of radon diagnosis procedures has been applied in order to localise and quantify radon entry pathways into the indoor environment. Independent assessment of radon entry rate and air exchange rate has been carried out using the continuous indoor radon measurement and a specific tracer gas application.

View Article and Find Full Text PDF

The sources of gamma radiation inside buildings affected by earlier silver and uranium mining activities are discussed. Possibilities how to reduce gamma dose rates from building materials were studied on several houses located in the old mining town Jáchymov. Results of the efficiency analysis are presented.

View Article and Find Full Text PDF

An efficiency analysis of remedial measures launching in the Czech Republic before 2004 revealed that in 52% of houses the remediation was not successful. An example of the house with an ineffective mitigation is described in order to present radon diagnosis procedures focused on the identification of critical factors responsible for the remedial mitigations insufficiency. A description of additional measures application is presented and results of the final efficiency evaluation are discussed.

View Article and Find Full Text PDF

The continual soil-gas radon concentration measurements are absolutely crucial for a reliable assessment of radon entry characteristics into the indoor building environment. For this purpose, a new detection system (a continuous monitor RM-3) was developed and tested. The detection principle of the monitoring device is based on an airflow ionisation chamber operating in a current mode.

View Article and Find Full Text PDF

The health risk and dose calculations from exposure to indoor radon and its decay products are generally based on long-term integral measurements and standard ICRP recommendations. In this context, the results of assessments predicate more about human activities inside the building instead of a quality and an effectiveness of applied measures against the radon. The present paper is focused on a set of different measuring techniques and methods practically used for a classification of buildings regarding to the radon protection requirements.

View Article and Find Full Text PDF