In this cadaveric study, we compared the performance of the TOUCH® dual mobility trapeziometacarpal prosthesis implanted sequentially in the trapeziometacarpal joint and scaphometacarpal joint. Intraprosthetic mobility, implant dislocation, intraprosthetic impingement and the effect on scaphoid position were evaluated in six hands using radiographic measurements. The standard necks of 6-10 mm were used for trapeziometacarpal arthroplasty.
View Article and Find Full Text PDFIn a previous cadaver study, we directly measured the load acting on the trapeziometacarpal joint for increasingly greater key pinch forces. We noted that the joint load ranges from 2 kg to 4 kg during progressively greater key pinch from 0.5 kg to 1.
View Article and Find Full Text PDFHand Surg Rehabil
April 2022
To our knowledge, no study has directly measured the loads in the trapeziometacarpal joint during an isometric key pinch. The aim of this study was to measure the load acting on the trapeziometacarpal joint for increasingly greater key pinch forces (0.5 kg-1.
View Article and Find Full Text PDFHand Surg Rehabil
December 2021
We performed a biomechanical study using 60 Sawbones® rigid foam blocks of two simulated densities (osteoporotic, n = 30 and non-osteoporotic, n = 30) and 10 cadaveric trapezium bones from fresh-frozen, unembalmed adult cadaver hands to assess the trapezial prosthetic cup migration with progressively greater compression loads (10-40 kg). Two cups from the Touch® prosthesis were compared: 9-mm conical cup and 9-mm spherical cup. Uniaxial compression tests were carried out using an MTS Criterion® Series 40 Electromechanical Testing System.
View Article and Find Full Text PDFWe performed a retrospective review of standard anteroposterior and lateral radiographs of the thumb in 80 patients, to compare two radiographic landmarks, in terms of mediolateral bone support, for centering the trapezial component in total joint arthroplasty. On anteroposterior view, we identified the distal articular surface of the trapezium and trapezium width, and defined the two midpoints as radiographic landmarks for positioning a 9-mm trapezial cup. Mean trapezium width was significantly greater than the distal articular surface of the trapezium, and the midpoints did not match.
View Article and Find Full Text PDFWe present a design for the experimental integration of ion trapping and superconducting qubit systems as a step towards the realization of a quantum hybrid system. The scheme addresses two key difficulties in realizing such a system: a combined microfabricated ion trap and superconducting qubit architecture, and the experimental infrastructure to facilitate both technologies. Developing upon work by Kielpinski et al.
View Article and Find Full Text PDFBackground: Nitric oxide (NO) shows differing concentrations in lower and upper airways. Patients after total laryngectomy are the only individuals, in whom a complete separation of upper and lower airways is guaranteed. Thus the objective of our study was to assess exhaled and nasal NO in these patients.
View Article and Find Full Text PDFBackground: Due to large-scale destruction, changes in membrane diffusion (Dm) may occur in cystic fibrosis (CF), in correspondence to alterations observed by computed tomography (CT). Dm can be easily quantified via the diffusing capacity for nitric oxide (DLNO), as opposed to the conventional diffusing capacity for carbon monoxide (DLCO). We thus studied the relationship between DLNO as well as DLCO and a CF-specific CT score in patients with stable CF.
View Article and Find Full Text PDFJ Investig Allergol Clin Immunol
May 2009
Background: The fraction of exhaled nitric oxide (FE(NO)) has been found reduced 4 to 6 weeks after an educational intervention in farmers with occupational asthma.
Objective: To reveal whether long-term changes in FE(NO) would still be detectable a year after the intervention.
Methods: We evaluated airway inflammation and obstruction at baseline and after 1 year in animal farmers with occupational asthma (n = 43, 16 women, mean [SD] age, 46.
J Investig Allergol Clin Immunol
October 2008
Measurement of exhaled nitric oxide is widely used in respiratory research and clinical practice, especially in patients with asthma. However, interpretation is often difficult, due to common interfering factors, and little is known about interactions between factors. We assessed the influences and interactions of factors such as smoking, respiratory tract infections and respiratory allergy concerning exhaled nitric oxide values, with the aim to derive a scheme for adjustment.
View Article and Find Full Text PDFBackground: The combined measurement of diffusing capacity of the lung for nitric oxide (Dlno) and diffusing capacity of the lung for carbon monoxide (Dlco) is a simple, noninvasive tool, but methodologic factors might influence results and reproducibility. We thus quantified the influence of breath-hold time on Dlco and Dlno in subjects with or without airway disease.
Methods: Simultaneous single-breath measurements of Dlco and Dlno were performed in 10 patients with cystic fibrosis (CF) [mean +/- SD age, 33 +/- 9 years; FEV(1), 69 +/- 28% of predicted] and 10 healthy subjects (age, 31 +/- 9 years; FEV(1), 108 +/- 8% of predicted), using the Masterscreen PFT (Viasys/Jaeger; Höchberg, Germany), with 45 ppm of inspired nitric oxide (NO), and breath-hold times of 4 s, 6 s, 8 s, and 10 s.
Allergic occupational asthma is frequent in farming populations. As educational interventions can improve disease management, the short-term effect of an educational intervention in asthmatic farmers was evaluated on the basis of spirometric indices and exhaled nitric oxide fraction (F(eNO)). Farmers with occupational asthma (n = 81), mostly sensitised against cow dander and storage mites, participated in a 1-day educational programme.
View Article and Find Full Text PDFBackground: Within a study on respiratory symptoms in rural areas, we used the European Community Respiratory Health Survey methacholine challenge protocol. For quicker and more reliable handling, we had to change the nebulizer in the bronchial challenge system from Mefar model MB3 (Bovezzo, Italy) to Jaeger APS Sidestream (similar to Mefar; Würzburg, Germany). Therefore, we compared the physical properties of the two systems, adapted the challenge protocol, and compared the results of both systems in subjects with and without airway hyperresponsiveness to methacholine.
View Article and Find Full Text PDFThe aim of this study was to determine if adults spontaneously exploit the laws of physics to achieve better accuracy when throwing at various distances. Eight adults performed 25 underarm throws at five horizontal circular targets located 4, 5, 6, 7 and 8 m away with a constant 5% relative accuracy requirement. Angle and speed of the ball at release were found to increase with throwing distance, while the coordinates of the release point did not change significantly.
View Article and Find Full Text PDFActa Neuropathol
September 1976
Electron microscope observations were made of rat peroneal nerve after crushing using intravenously injected horseradish peroxidase (HRP) as a tracer protein to indicate changes in vascular permeability. At 1/2 h and 2 d after the crush there was gross leakage of HRP from damaged capillaries at the site of injury but none from vessels above or below this. Ultrastructurally vessels at the site of crush showed broken and separated endothelial cells.
View Article and Find Full Text PDFThe response of the perineurium to the following experimental systems was investigated by light and electron microscopy: nerve crush, cold lesion and microinjection of (a) histamine liberator, (b) potassium cyanide, (c) lysophosphatidyl choline (LPC). Where myelin breakdown occurred, lipid globules were seen within Schwann cells, macrophages and also perineurial cells. Where increased vascular permeability occurred, proteinaceous material leaked from endoneurial vessels into the endoneurial space and later appeared between perineurial laminae.
View Article and Find Full Text PDF