The assessment of potential radon-hazardous environments is nowadays a critical issue in planning, monitoring, and developing appropriate mitigation strategies. Although some geological structures (e.g.
View Article and Find Full Text PDFPurpose: The aim of this work was to analyze the exposure rates measured in the proximity of patients who underwent prostate low-dose-rate brachytherapy with I-125 implant. Effective doses to relatives and to population were computed to estimate the time to reach radioprotection dose constraints.
Methods And Materials: Measurements were obtained from 180 patients, whereas the body mass index was calculated and reported for 77 patients.
The slowing down equation for elastic scattering of neutrons in an infinite homogeneous medium is solved analytically by decomposing the neutron energy spectrum into collision intervals. Since scattering physically smooths energy distributions by redistributing neutron energy uniformly, it is informative to observe how mathematics accommodates the scattering process, which increases entropy through disorder.
View Article and Find Full Text PDFIn the planning of a new cyclotron facility, an accurate knowledge of the radiation field around the accelerator is fundamental for the design of shielding, the protection of workers, the general public and the environment. Monte Carlo simulations can be very useful in this process, and their use is constantly increasing. However, few data have been published so far as regards the proper validation of Monte Carlo simulation against experimental measurements, particularly in the energy range of biomedical cyclotrons.
View Article and Find Full Text PDFRadiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calculation of shielding and materials activation, in approximate or idealised geometry set-ups. The availability of Monte Carlo (MC) codes with accurate up-to-date libraries for transport and interaction of neutrons and charged particles at energies below 250 MeV, together with the continuously increasing power of modern computers, makes the systematic use of simulations with realistic geometries possible, yielding equipment and site-specific evaluation of the source terms, shielding requirements and all quantities relevant to RP at the same time.
View Article and Find Full Text PDFThe Euganean Hills of North East Italy have long been recognised as an area characterized by a higher than average natural radiation background. This is due to two main reasons: a) primary lithogenic radiation due to rhyolitic and trachytic outcrops, which are "acidic alkaline" magmatic rocks potentially enriched in uranium and thorium; b) secondary sources related to a geothermal field - widely exploited for spa tourism in the area since the Roman age - producing surface release of radon-enriched fluids. Though radioactivity levels in the Euganean district have been often investigated in the past - including recent works aimed at assessing the radiation doses from radon and/or total gamma radiation - no effort has been put so far into producing a thorough assessment linking radiation protection data to geological-structural features (lithology, faults, water, organic matter content, etc.
View Article and Find Full Text PDFObjective: When handling Y-labelled and Lu-labelled radiopharmaceuticals, skin exposure is mainly due to β-particles. This study aimed to investigate the equivalent dose saving of the staff when changing from an essentially manual radiolabelling procedure to an automatic dose dispenser (ADD).
Materials And Methods: The chemist and physician were asked to wear thermoluminescence dosimeters on their fingertips to evaluate the quantity of Hp(0.
In view of assessing natural radioactivity with on-site quantitative gamma spectrometry, efficiency calibration of NaI(Tl) detectors is investigated. A calibration based on Monte Carlo simulation of detector response is proposed, to render reliable quantitative analysis practicable in field campaigns. The method is developed with reference to contact geometry, in which measurements are taken placing the NaI(Tl) probe directly against the solid source to be analyzed.
View Article and Find Full Text PDFIn a medical cyclotron facility, (41)Ar (t1/2 = 109.34 m) is produced by the activation of air due to the neutron flux during irradiation, according to the (40)Ar(n,γ)(41)Ar reaction; this is particularly relevant in widely diffused high beam current cyclotrons for the production of PET radionuclides. While theoretical estimations of the (41)Ar production have been published, no data are available on direct experimental measurements for a biomedical cyclotron.
View Article and Find Full Text PDFA comparative study has been performed on the effects of high-dose-rate (DR) X-ray beams produced by a plasma focus device (PFMA-3), to exploit its potential medical applications (e.g. radiotherapy), and low-DR X-ray beams produced by a conventional source (XRT).
View Article and Find Full Text PDFEnviron Geochem Health
April 2015
Vulsini Volcanic district in Northern Latium (Central Italy) is characterized by high natural radiation background resulting from the high concentrations of uranium, thorium and potassium in the volcanic products. In order to estimate the radon radiation risk, a series of soil gas radon measurements were carried out in Bolsena, the principal urban settlement in this area NE of Rome. Soil gas radon concentration ranges between 7 and 176 kBq/m(3) indicating a large degree of variability in the NORM content and behavior of the parent soil material related in particular to the occurrence of two different lithologies.
View Article and Find Full Text PDFThe electron beam emitted backward by plasma focus devices is being considered as a radiation source for Intra-Operative Radiation Therapy (IORT) applications. Radiobiological investigations have been conducted to assess the potential of this new prototype of IORT device. A standard x-ray beam, ISO-H60, was used for comparison, irradiating cell cultures in a holder filled with an aqueous solution.
View Article and Find Full Text PDFThe follow-up of Fukushima radioactive plume resulting from the 11th March 2011 devastating tsunami is discussed for two Italian stations in the northern Apennines: Mt. Cimone (Modena) and Montecuccolino (Bologna). Radioactivity data collected at both stations are described, including comparison between local natural background of airborne particulate and artificial radioactivity referable to the arrival of the radioactive plume and its persistence and evolution.
View Article and Find Full Text PDFThe electron beam emitted from the back of plasma focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A plasma focus device is being developed for this purpose, and there is a need for characterizing its electron beam, particularly, insofar as the energy spectrum is concerned. The instrument used is a magnetic spectrometer.
View Article and Find Full Text PDFThe widely used Monte Carlo simulation code FLUKA has been utilized to prototype a solid target for the production of (89)Zr by irradiation of a metallic (89)Y target foil in a 16.5MeV proton biomedical cyclotron, through the reaction (89)Y(p, n)(89)Zr. Simulations were performed with and without an Al energy degrader.
View Article and Find Full Text PDFThis paper deals with finding accurate solutions for photon transport problems in highly heterogeneous media fastly, efficiently and with modest memory resources. We propose an extended version of the analytical discrete ordinates method, coupled with domain decomposition-derived algorithms and non-linear convergence acceleration techniques. Numerical performances are evaluated using a challenging case study available in the literature.
View Article and Find Full Text PDFAppl Radiat Isot
August 2011
In this work a compact system was designed for bulk sample analysis using the technique of PGNAA. The system consists of (252)Cf fission neutron source, a moderator/reflector/filter assembly, and a suitable enclosure to delimit the resulting neutron beam. The moderator/reflector/filter arrangement has been optimised to maximise the thermal neutron component useful for samples analysis with a suitably low level of beam contamination.
View Article and Find Full Text PDFAppl Radiat Isot
August 2011
The partial-body counter currently installed at KIT is under redesign to add whole-body counting capabilities and replace the current phoswich detectors with HPGe ones, capable of detecting low energy photons ((210)Pb, (241)Am). Different configurations for the positioning of the subject have been tested with the aid of Monte Carlo simulations and the performances attainable with a sitting and a lying configuration were compared. The optimal placement of the detectors was also defined.
View Article and Find Full Text PDFA goal of whole body counting (WBC) is the estimation of the total body burden of radionuclides disregarding the actual position within the body. To achieve the goal, the detectors need to be placed in regions where the photon flux is as independent as possible from the distribution of the source. At the same time, the detectors need high photon fluxes in order to achieve better efficiency and lower minimum detectable activities.
View Article and Find Full Text PDFWith the ever-increasing number of cyclotron installations, and therefore of the maintenance personnel involved, the possibility of swift, 'yes or no' screening for internal contamination becomes a prized asset. The present work presents one such procedure, evolved from an approximate whole body counting technique in widespread use in emergency situations. A detailed analysis of possible pathways for contamination leads to pinpointing the nuclides of interest.
View Article and Find Full Text PDFAppl Radiat Isot
October 2010
Ozone produced from radiolytic processes was investigated as a possible health hazard in the working environment at the University Hospital "S.Orsola--Malpighi" PET facility. Intense radiation fields can generate ozone, known to be the most toxic gas produced by ionizing radiation around a particle accelerator.
View Article and Find Full Text PDFThe purpose of this work is to evaluate the dose rate distribution and to determine the boron effect on dose rate distribution for (252)Cf brachytherapy source. This study was carried out using a Monte Carlo simulation. To validate the Monte Carlo computer code, the dosimetric parameters were determined following the updated TG-43 formalism and compared with current literature data.
View Article and Find Full Text PDFJ Radiol Prot
December 2007
A plasma focus is being developed for breeding short-lived radionuclides. The different radiation protection issues and concerns posed by the machine once in operation are analysed and discussed. Activation is shown to be totally negligible and likewise neutron emission is found to pose no concern at all.
View Article and Find Full Text PDFBetween 2001 and 2003 a 3.2 kJ dense plasma focus (DPF) device has been built at the Montecuccolino Laboratory of the Department of Energy, Nuclear and Environmental Control Engineering (DIENCA) of the University of Bologna. A DPF is a pulsed device in which deuterium nuclear fusion reactions can be obtained through the pinching effects of electromagnetic fields upon a dense plasma.
View Article and Find Full Text PDF