Background: To further reduce the invasiveness of arthroscopic rotator cuff repair surgery the all-suture anchor has been developed. The all-suture anchor requires less bone removal and reduces the potential of loose body complications. The all-suture anchor must also have adequate biomechanical strength for the repair to heal.
View Article and Find Full Text PDFBackground: Suspensory fixation use during anterior cruciate ligament reconstruction has increased due to ease of use and high pullout strength. We hypothesize that there are no significant differences in biomechanical performance among four types of suspensory fixation devices: Stryker VersiTomic G-Lok, Smith & Nephew Endobutton, Biomet ToggleLoc, and Arthrex RetroButton.
Methods: Forty fresh frozen porcine femurs and flexor digitorum profundus tendons were obtained.
The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity.
View Article and Find Full Text PDFBackground: The development of highly vascularized and inflammatory periprosthetic tissue characterizes the progress of aseptic loosening, a major complication of joint arthroplasty. Vascular endothelial growth factor (VEGF) is an important cell signaling protein involved in angiogenesis. The purpose of this study was to investigate whether R2/Fc (a VEGF neutralizing antibody) and SU5416 (a VEGF receptor II [Flk-1] inhibitor) could ameliorate particle-induced inflammatory osteolysis in a mouse model.
View Article and Find Full Text PDFJ Long Term Eff Med Implants
April 2011
This study investigated a highly porous titanium foam with and without a PeriApetite coating as an alternative surface for implant fixation. Twelve mongrel canines received staged total hip replacements under International Animal Care and Use Committee (IACUC) approval from our institution. Animals were randomly placed in three- or six-month groups for sacrifice.
View Article and Find Full Text PDFOur study was designed to evaluate osseointegration among implants with three surface treatments: plasma-sprayed titanium (P), plasma-sprayed titanium with hydroxyapatite (PHA), and chemical-textured titanium with hydroxyapatite (CHA). Average surface roughness (Ra) was 27 microns for the P group, 17 microns for the PHA group, and 26 microns for the CHA group. Bilateral distal intramedullary implants were placed in the femora of thirty rabbits.
View Article and Find Full Text PDFObjectives: We have reported that oral erythromycin (EM) inhibits periprosthetic tissue inflammation in a group of patients with aseptic loosening. The purpose of this study was to assess the efficacy of local, periprosthetic EM delivery in a rat model.
Methods: Uncoated Ti pins were press-fit into the right tibia of fourteen Sprague-Dawley rats following an intramedullar injection of UHMWPE (ultra high molecular weight polyethylene) particles.
Objectives: A highly vascularized and inflammatory periprosthetic tissue augments the progress of aseptic loosening, a major clinical problem after total joint replacement. The purpose of this study is to investigate the effect of erythromycin (EM) on ultra high molecular weight polyethylene (UHMWPE) particle-induced VEGF/VEGF receptor 1 (Flt-1) gene production and inflammatory osteolysis in a mouse model.
Methods: UHMWPE particles were introduced into established air pouches on BALB/c mice, followed by implantation of calvaria bone from syngeneic littermates.
We investigated histological and compressive properties of a calcium phosphate bone cement (BoneSource (CPC); Stryker Orthopaedics, Mahwah, New Jersey) plus carboxymethyl cellulose (CMC) using a sheep vertebral bone void model. Bone voids were surgically created in L3 and L5 in each of 40 sheep, and the voids were filled with the cement. Histological and radiographic evaluations were performed on one vertebral body from each animal at either: 0, 3, 6, 12, 24, or 36 months after surgery; mechanical testing was performed on operated and non-operated vertebral bodies from 35 sheep.
View Article and Find Full Text PDFObjective: Aseptic loosening is a common complication of total joint replacement in humans. Our study examined the hypothesis that wear debris may influence vascular endothelial grow factor (VEGF) expression, and that blocking VEGF bioactivity might improve wear debris-induced inflammatory osteolysis in a mouse model.
Methods: Ultra high molecular weight polyethylene (UHMWPE) particles were introduced into established air pouches on BALB/c mice, followed by implantation of calvaria bone from syngeneic littermates.
Wear debris-induced vascularized granulomatous periprosthetic tissue may augment the progress of prosthetic loosening, a major clinical problem after total joint replacement. The purpose of this study is to investigate the association of ultra-high-molecular-weight polyethylene (UHMWPE) particle-induced inflammatory osteoclastogenesis and expression of RANK/RANKL and VEGF/VEGF receptors (Flt-1 and Flk-1) using a mouse osteolysis model. UHMWPE particles were introduced into established air pouches on BALB/c mice, followed by implantation of calvaria bone from syngeneic littermates.
View Article and Find Full Text PDFSolution precipitation of calcium and phosphate is a technique to generate hydroxyapatite [Peri-Apatitetrade mark (PA), Stryker Orthopaedics, Mahwah, NJ] on metal substrate. This study was carried out to determine the capacity of PA to adsorb osteogenic protein-1 (OP-1) and the time course of release, and to determine the osteoinductive activity of OP-1. The adsorption and release studies were conducted with (125)I-labeled OP-1- and PA-coated titanium alloy disks.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
November 2004
This study evaluated the effect of osteogenic protein-1 (OP-1) carried by Peri-Apatite (PA) on bone healing in the gap surrounding implants in a rabbit model. Cylindrical titanium implants (3 x 9 mm) were uniformly coated with PA precipitated from a calcium and phosphate solution. OP-1 solution containing 60 microg OP-1 was directly loaded on the implants immediately before implantation for the experimental group, whereas buffer solution was loaded on the implants for the control.
View Article and Find Full Text PDF