Publications by authors named "Monica Echeverry-Rendon"

Cartilage defect repair with optimal efficiency remains a significant challenge due to the limited self-repair capability of native tissues. The development of bioactive scaffolds with biomimicking mechanical properties and degradation rates matched with cartilage regeneration while simultaneously driving chondrogenesis, plays a crucial role in enhancing cartilage defect repair. To this end, a novel composite scaffold with hierarchical porosity was manufactured by incorporating a pro-chondrogenic collagen type I/II-hyaluronic acid (CI/II-HyA) matrix to a 3D-printed poly(glycerol sebacate) (PGS) framework.

View Article and Find Full Text PDF

Bioabsorbable Mg wire-reinforced poly-lactic acid (PLA) matrix composites are potential candidate for load-bearing orthopedic implants offering tailorable mechanical and degradation properties by stacking sequence, volume fraction and surface modification of Mg wires. In this study, we investigated the cytocompatibility, cell-material interaction, and bone differentiation behavior of MC3T3-E1 pre-osteoblast cells for medical-grade PLA, Mg/PLA, and PEO-Mg/PLA (having PEO surface modification on Mg wires) composites. MTT and live/dead assay showed excellent biocompatibility of both composites while cell-material interaction analysis revealed that cells were able to adhere and proliferate on the surface of composites.

View Article and Find Full Text PDF

Medical grade PLDL, PLDL/Mg and PLDL/Zn filaments were manufactured by a dual extrusion method and used to prepare coupons and scaffolds with controlled porosity by fused filament fabrication. The mechanical properties, degradation mechanisms and biological performance were carefully analyzed. It was found that the presence of 4 vol.

View Article and Find Full Text PDF

Cardiovascular stenting is the most widely used therapy to treat coronary artery disease caused by partial or total obstruction of the artery due to atherosclerotic plaque formation, with potentially fatal effects. There are different types of stents: bare metal stents, drug-eluting stents, bioabsorbable stents and dual therapy stents. However, they can lead to long-term complications, such as in-stent restenosis and late thrombosis.

View Article and Find Full Text PDF

The corrosion, mechanical degradation and biological performance of cold-drawn WE43 Mg wires were analyzed as a function of thermo-mechanical processing and the presence of a protective oxide layer created by continuous plasma electrolytic oxidation (PEO). It was found that the corrosion properties of the non-surface-treated wire could be optimized by means of thermal treatment within certain limits, but the corrosion rate remained very high. Hence, strength and ductility of these wires vanished after 24 h of immersion in simulated body fluid at 37 °C and, as a result of that rather quick degradation, direct tests did not show any MC3T3-E1 preosteoblast cell attachment on the surface of the Mg wires.

View Article and Find Full Text PDF

Magnesium alloys are being studied for use in temporary orthopedic implants because of their mechanical properties, which are similar to those of human bone, and their good biocompatibility. However, their application is limited due to their rapid degradation, and early loss of their mechanical properties, decreasing the stability of the implant and its proper synchronization with tissue regeneration. In this regard, various surface coatings have been used to improve their biological, physico-chemical and biodegradation properties.

View Article and Find Full Text PDF

Magnesium-based nanoparticles have shown promise in regenerative therapies in orthopedics and the cardiovascular system. Here, we set out to assess the influence of differently functionalized Mg nanoparticles on the cellular players of wound healing, the first step in the process of tissue regeneration. First, we thoroughly addressed the physicochemical characteristics of magnesium hydroxide nanoparticles, which exhibited low colloidal stability and strong aggregation in cell culture media.

View Article and Find Full Text PDF

One of the most common magnesium (Mg) applications in the biomedical field is in cardiovascular stents. Although Mg is an essential element for homeostasis, Mg is highly reactive, and locally high Mg concentrations can have toxic effects on the surrounding tissue. One strategy to circumvent the Mg toxicity is using coatings or surface modifications that prevent the leaching of excessive Mg ions.

View Article and Find Full Text PDF

The shear strength and the corrosion resistance of the fiber/matrix interface after immersion in simulated body fluid was studied in poly-lactic acid/Mg fiber composites. The shear strength of the interface was measured by means of push-out tests in thin slices of the composite perpendicular to the fibers. It was found that the interface strength dropped from 15.

View Article and Find Full Text PDF

Magnesium and its alloys have been recently used in biomedical applications such as orthopedic implants, whereas the weak corrosion resistance undermines their clinical efficacy. Herein, to address this critical challenge, the preparation of hierarchically structured hydroxyapatite-based coatings was proposed. Compact coatings were fabricated on a Mg alloy through a facile two-step method of chemical deposition of brushite precursor and subsequent hydrothermal conversion.

View Article and Find Full Text PDF

Magnesium (Mg) is a material widely used in industrial applications due to its low weight, ductility, and excellent mechanical properties. For non-permanent implants, Mg is particularly well-suited because of its biodegradability, while its degradation products are not harmful. However, Mg is chemically reactive, and cytotoxic hydrogen gas is released as part of the degradation.

View Article and Find Full Text PDF

Nanotubular structures were produced on a commercially pure titanium surface by anodization in an aqueous electrolyte that contained carboxymethyl cellulose and sodium fluoride. The internal diameters obtained were about 100, 48, and 9.5 nm, respectively.

View Article and Find Full Text PDF

Metal stents are used as base material for fabrication of medical devices to support and improve the quality of life of patients with cardiovascular diseases such as arterial stenoses. Permanently present implants may induce responses that resemble adverse wound healing that compromise tissue function. A similar process namely restenosis, frequently may occur after the use of this kind of implants.

View Article and Find Full Text PDF

Despite the well-known advantages of the titanium-based implant systems, they still lack an optimal balance between biofunctionality and mechanical strength, especially regarding the modulation of cellular response and a desired implant osseointegration. In this work, we fabricated a nanocomposite based on porous commercially pure grade 4 titanium (c.p.

View Article and Find Full Text PDF

Surgical clipping and endovascular coiling are well recognized as conventional treatments of Penetrating Brain Injury aneurysms. These clinical approaches show partial success, but often result in thrombus formation and the rupture of aneurysm near arterial walls. The authors address these challenging brain traumas with a unique combination of a highly biocompatible biopolymer hydrogel rendered magnetic in a flexible and resilient membrane coating integrated to a scaffold stent platform at the aneurysm neck orifice, which enhances the revascularization modality.

View Article and Find Full Text PDF

The optimal mechanical properties render magnesium widely used in industrial and biomedical applications. However, magnesium is highly reactive and unstable in aqueous solutions, which can be modulated to increase stability of reactive metals that include the use of alloys or by altering the surface with coatings. Plasma electrolytic oxidation is an efficient and tuneable method to apply a surface coating.

View Article and Find Full Text PDF

Nanotubular structures were generated on the surface of titanium c.p. by anodization technique in an aqueous solution of acetic acid (14% v/v) with different sources of fluoride ion (HF, NaF, NH F).

View Article and Find Full Text PDF

Surface characteristics can mediate biological interaction improving or affecting the tissue integration after implantation of a biomaterial. Features such as topography, wettability, surface energy and chemistry can be key determinants for interactions between cells and materials. Plasma electrolytic oxidation (PEO) is a technique used to control this kind of parameters by the addition of chemical species and the production of different morphologies on the surfaces of titanium and its alloys.

View Article and Find Full Text PDF

Current treatments for brain aneurysms are invasive, traumatic, and not suitable in most patients with increased risks. A new alternative method is using scaffold stents to create a local and focal attraction force of cells for an in situ reconstruction of the tunica media. For this purpose, a nanostructured bioactive coating is designed to render an asymmetric region of the stent scaffold magnetic and biomimetic, which utilizes bacterial nanocellulose (BNC) as a platform for both magnetic and cell attraction as well as proliferation.

View Article and Find Full Text PDF

In this study, bacterial nanocellulose (BNC) produced by the bacteria Gluconacetobacter xylinus is synthesized and impregnated in situ with iron oxide nanoparticles (IONP) (Fe3O4) to yield a magnetic bacterial nanocellulose (MBNC). The synthesis of MBNC is a precise and specifically designed multi-step process. Briefly, bacterial nanocellulose (BNC) pellicles are formed from preserved G.

View Article and Find Full Text PDF

Titanium (Ti) is a material frequently used in orthopedic applications, due to its good mechanical properties and high corrosion resistance. However, formation of a non-adherent fibrous tissue between material and bone drastically could affect the osseointegration process and, therefore, the mechanical stability of the implant. Modifications of topography and configuration of the tissue/material interface is one of the mechanisms to improve that process by manipulating parameters such as morphology and roughness.

View Article and Find Full Text PDF