Purpose: The aim of our study was to investigate the technical accuracy of susceptibility-weighted imaging (SWI) and quantitative susceptibility mapping (QSM) created to detect intramammary-like calcifications depending on different TEs, volume, and type of calcification samples at 1.5T.

Methods: Jello-embedded particles of blackboard chalk and ostrich eggshell ranging in size from 4 to 25 mm were used to simulate intramammary calcifications after testing different base substances and calcifications for their suitability to be used in breast phantoms.

View Article and Find Full Text PDF

Background: Liver fibrosis has been recognized as a long-term morbidity associated with Fontan circulation (Fontan-associated liver disease, FALD). The pathophysiology of FALD is not completely understood and abnormal flow dynamics may be associated with this condition. Liver hemodynamics can be quantitatively evaluated with four-dimensional phase-contrast flow magnetic resonance imaging (4D PC flow MRI).

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to develop a non-contrast MRI/MRA protocol to evaluate kidney function and identify abnormalities in living kidney donors.
  • A total of 28 subjects underwent various imaging techniques, including pCASL and two MRA methods, to assess renal perfusion and visualize renal arteries.
  • The results indicated that the new protocol reliably assessed kidney function within 10 minutes, avoiding risks associated with contrast agents and radiation.
View Article and Find Full Text PDF

. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors.

View Article and Find Full Text PDF

Purpose: Multiple sclerosis (MS) is a prevalent autoimmune inflammatory disease. Besides cerebral manifestations, an affection of the spinal cord is typical; however, imaging of the spinal cord is difficult due to its anatomy. The aim of this study was to assess the diagnostic value of a 3D PSIR pulse sequencing at a 1.

View Article and Find Full Text PDF

The value of biofeedback before elective coronary computed tomography angiography (CCTA) to reduce patients' heart rates (HR) was investigated in the current work. Sixty patients who received CCTA to exclude coronary artery disease were included in our study and separated into two groups: with biofeedback (W-BF) and without biofeedback (WO-BF). The W-BF group used a biofeedback device for 15 min before CCTA.

View Article and Find Full Text PDF

Objectives: Pulmonary valve regurgitation is a common problem after relief of right ventricular outflow tract (RVOT) obstruction with a transannular patch. Pulmonary valve replacement with a homograft or xenograft is the routine treatment. Longevity of biological valves and the availability of homografts are limited.

View Article and Find Full Text PDF

(1) Background: Preoperative imaging of the lower leg arteries is essential for planning fibular grafting. The aim of this study was to evaluate the feasibility and clinical value of non-contrast-enhanced (CE) Quiescent-Interval Slice-Selective (QISS)-magnetic resonance angiography (MRA) for reliably visualizing the anatomy and patency of the lower leg arteries and for preoperatively determining the presence, number, and location of fibular perforators. (2) Methods: The anatomy and stenoses of the lower leg arteries and the presence, number, and location of fibular perforators were determined in fifty patients with oral and maxillofacial tumors.

View Article and Find Full Text PDF

Purpose: Contrast-enhanced (CE) angiographic techniques, such as computed tomographic angiography (CE-CTA), are most commonly used for follow-up imaging after endovascular aneurysm repair. In this study, CE-CTA and non-CE QISS-MRA were compared for the first time for assessing endoleaks and aneurysms at follow-up after abdominal EVAR.

Methods: Our study included 20 patients (17 male, median age 79.

View Article and Find Full Text PDF

Four-dimensional (4D) flow MRI allows quantifying flow in blood vessels-non invasively and in vivo. The clinical use of 4D flow MRI in small vessels, however, is hampered by long examination times and limited spatial resolution. Compressed SENSE (CS-SENSE) is a technique that can accelerate 4D flow dramatically.

View Article and Find Full Text PDF

(1) Deep hypothermic circulatory arrest (DHCA) with selective antegrade cerebral perfusion (ACP) is an established cerebral protection technique for the conduction of complex surgical procedures involving the aortic arch. It is controversial whether the duration of DHCA is associated with adverse outcome in patients with acute type A aortic dissection (AAAD). Our goal was to investigate whether DHCA time was associated with surgical outcome in patients undergoing a surgical treatment of AAAD.

View Article and Find Full Text PDF

Background: It is controversial if the type or the size of aortic dissection is associated with the mortality in patients with acute aortic dissection (AAD) type I or type II according to DeBakey. Due to the pronounced aortic pathology in DeBakey type I compared to DeBakey type II, it is to be expected, that the DeBakey type I is associated with a significant higher morbidity and mortality. But we hypothesize that the current advances in surgical techniques, circulatory management, and postoperative care improve the clinical outcome of patients with DeBakey type I and II.

View Article and Find Full Text PDF

Objectives: To evaluate the ability of non-contrast enhanced magnetic resonance imaging (MRI) techniques to characterize Fontan associated liver disease (FALD) in adolescent and adult Fontan patients.

Methods: Fontan patients (n = 29) and healthy controls (n = 13) underwent an MRI protocol with T, T and Apparent Diffusion Coefficient (ADC) mapping. Routine FALD screening included abdominal ultrasound and laboratory testing.

View Article and Find Full Text PDF

This work focuses on implementing a standardized and symptom-oriented flowchart for advanced cardiac imaging in a 24/7 emergency setting using a dual-layer spectral detector CT system. This flowchart was designed to optimize patient management and standardize imaging workflow. It includes acquisition parameters and contrast agent protocols for the most relevant clinical questions regarding cardiac CT imaging in the interdisciplinary emergency department.

View Article and Find Full Text PDF

Background: Soft-tissue sarcomas (STS) are rare malignancies of the soft tissue.

Purpose: To assess whether the magnetic resonance imaging (MRI) configuration of primary STS can predict the configuration of a recurring tumor and whether the MRI configuration of multiple recurrences differs in one and the same patient.

Material And Methods: Thirty-nine patients with histologically proven recurrent STS were included in this retrospective study and underwent pre- and post-treatment MRI.

View Article and Find Full Text PDF

Ventricular dysfunction is a well-known complication in single ventricle patients in Fontan circulation. As studies exclusively examining patients with a single left ventricle (SLV) are sparse, we assessed left ventricular (LV) function in SLV patients by using 2D-cardiovascular magnetic resonance (CMR) feature tracking (2D-CMR-FT) and 2D-speckle tracking echocardiography (2D-STE). 54 SLV patients (11.

View Article and Find Full Text PDF

Purpose: Recurrent stroke is considered to increase the incidence of severe disability and death. For correct risk assessment and patient management it is essential to identify the origin of stroke at an early stage. Transthoracic echocardiography (TTE) is the initial standard of care for evaluating patients in whom a cardioembolic source of stroke (CES) is suspected but its diagnostic capability is limited.

View Article and Find Full Text PDF

Background: The aim of the study was to assess whether the configuration of primary soft-tissue sarcoma (STS) on MRI correlates with the grade of malignancy.

Patients And Methods: 71 patients with histologically proven STS were included. Primary STS were examined for configuration, borders, and volume on MRI.

View Article and Find Full Text PDF

Purpose: Non-contrast-enhanced (CE) magnetic resonance angiography (MRA) techniques are of considerable interest for diagnosing vascular diseases in the upper extremities owing to the possibility of repeated examinations, sufficient coverage of the measurement volume, and because possible side effects of administering iodine- or gadolinium-based contrast agents and radiation exposure can be avoided. The aim of this study was to investigate the feasibility of an optimized electrocardiogram (ECG) triggered Cartesian quiescent interval slice selective (QISS) technique for MRA of hand arteries.

Material And Methods: Both hands of 20 healthy volunteers (HVs) were examined using an optimized QISS-MRA pulse sequence at 1.

View Article and Find Full Text PDF

Background: Free-breathing noncontrast-enhanced (non-CE) magnetic resonance angiography (MRA) techniques are of considerable interest for the diagnosis of acute pulmonary embolism (APE), due to the possibility for repeated examinations, avoidance of side effects from iodine-based contrast agents, and the absence of ionizing radiation exposure as compared to CE-computed tomographic angiography (CTA).

Purpose: To analyze the clinical performance of free-breathing and electrocardiogram (ECG)-gated radial quiescent-interval slice-selective (QISS)-MRA compared to CE-CTA and to Cartesian balanced steady-state free precession (bSSFP)-MRA.

Study Type: Prospective.

View Article and Find Full Text PDF

Purpose: The aim of this study was to investigate the diagnostic value of myocardial deformation analysis based on the 17-segment heart model using non-contrast enhanced (CE) 2D tissue feature tracking (2D-FT) technique.

Material And Methods: Seventy patients with suspected myocarditis underwent a cardiovascular magnetic resonance (CMR) examination at 1.5 Tesla.