Purpose: This study investigated the correlation between the prescription dose and dose to the Manchester and International Commission on Radiation Units and Measurements-report 38 (ICRU-38) lymphatic trapezoid points during high-dose-rate (HDR) brachytherapy of locally advanced cervical cancer with (Cobalt-60) 60Co .
Methods And Materials: A retrospective study was designed for; patients with locally advanced cervical cancer, treated by external beam radiotherapy and concurrent weekly Cisplatin-based chemotherapy, had no extended parametrial invasion and was treated by tandem-ovoid set, from 2017 to 2020. Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO) based target's volume, ICRU-89 revised version of Manchester points A and B, and ICRU-38 lymph node surrogate points were determined, and their dose was recorded.