Background: Partial cardiac sympathetic reinnervation after cardiac transplant has been extensively investigated and evidenced. However, there have been no large-scale, long-term studies evaluating the prevalence, time-course, and association with long-term survival of sympathetic reinnervation of the heart.
Methods: Cardiac transplant recipients (n = 232) were recruited from outpatient clinic at a single transplant center in the United Kingdom.
Background: Recurrent ventricular tachycardia (VT) can be treated by substrate modification of the myocardial scar by catheter ablation during sinus rhythm without VT induction. Better defining this arrhythmic substrate could help improve outcome and reduce ablation burden.
Objective: The study aimed to limit ablation within postinfarction scar to conduction channels within the scar to reduce VT recurrence.
Background: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported.
View Article and Find Full Text PDFBackground: Three-dimensional (3D) mapping of the ventricular conduction system is challenging.
Objective: The purpose of this study was to use ripple mapping to distinguish conduction system activation to that of adjacent myocardium in order to characterize the conduction system in the postinfarct left ventricle (LV).
Methods: High-density mapping (PentaRay, CARTO) was performed during normal rhythm in patients undergoing ventricular tachycardia ablation.
Aims: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI.
View Article and Find Full Text PDFThe learning curve for the novel RHYTHMIA HDx™ 3-dimensional electroanatomic system is unknown. Retrospective data collection was carried out at 3 U.K.
View Article and Find Full Text PDFObjective: We aimed to compare cryoballoon pulmonary vein isolation (PVI) with standard radiofrequency cavotricuspid isthmus (CTI) ablation as first-line treatment for typical atrial flutter (AFL).
Methods: Cryoballoon Pulmonary Vein Isolation as First-Line Treatment for Typical Atrial Flutter was an international, multicentre, open with blinded assessment trial. Patients with CTI-dependent AFL and no documented atrial fibrillation (AF) were randomised to either cryoballoon PVI alone or radiofrequency CTI ablation.
Objectives: This analysis was performed to evaluate the transition of local impedance (LI) drop during pulmonary vein isolation (PVI) to durable block and mature lesion formation based on 3-month mapping procedures.
Background: A radiofrequency catheter measuring LI has been shown to be effective for performing PVI in patients with paroxysmal atrial fibrillation. Previous analysis has demonstrated LI drop to be predictive of pulmonary vein segment conduction block during an atrial fibrillation ablation procedure.
Introduction: The purpose of this study is to assess the ability of two new ECG markers (Regional Repolarisation Instability Index (R2I2) and Peak Electrical Restitution Slope) to predict sudden cardiac death (SCD) or ventricular arrhythmia (VA) events in patients with ischaemic cardiomyopathy undergoing implantation of an implantable cardioverter defibrillator for primary prevention indication.
Methods And Analysis: Multicentre Investigation of Novel Electrocardiogram Risk markers in Ventricular Arrhythmia prediction is a prospective, open label, single blinded, multicentre observational study to establish the efficacy of two ECG biomarkers in predicting VA risk. 440 participants with ischaemic cardiomyopathy undergoing routine first time implantable cardioverter-defibrillator (ICD) implantation for primary prevention indication are currently being recruited.
Aims: Radiofrequency ablation creates irreversible cardiac damage through resistive heating and this temperature change results in a generator impedance drop. Evaluation of a novel local impedance (LI) technology measured exclusively at the tip of the ablation catheter found that larger LI drops were indicative of more effective lesion formation. We aimed to evaluate whether LI drop is associated with conduction block in patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein isolation (PVI).
View Article and Find Full Text PDFPurpose: Treatment of typical atrial flutter (AFL) with cavo-tricuspid isthmus (CTI) ablation is associated with a high occurrence rate of new onset atrial fibrillation (AF) during follow-up. There are data to support the addition of pulmonary vein isolation (PVI) to CTI ablation in patients with both AF and AFL, but the role of cryoballoon PVI only, with no CTI ablation, in AFL patients with no prior documentation of AF has not been studied.
Methods: CRAFT is an international, prospective, randomised, open with blinded assessment, multicentre superiority study comparing radiofrequency CTI ablation and cryoballoon PVI in patients with typical AFL.
Purpose: Adverse left atrial (LA) remodeling is known to be associated with persistent atrial fibrillation (PeAF). The time course and pattern of reversal of LA remodeling following catheter ablation is poorly understood. We aimed to evaluate LA chamber volumes and dimensions, LA conduction velocities, and LA bipolar voltages at baseline and at 2 months after catheter ablation for PeAF.
View Article and Find Full Text PDFBackground: Although QRS duration (QRSd) is an important determinant of cardiac resynchronization therapy (CRT) response, non-responder rates remain high. QRS fragmentation can also reflect electrical dyssynchrony. We hypothesized that quantification of abnormal QRS peaks (QRSp) would predict CRT response.
View Article and Find Full Text PDFBackground Catheter ablation for persistent atrial fibrillation (AF) is associated with less favorable outcomes than for paroxysmal AF. Substrate modification is often added to pulmonary vein isolation (PVI) to try to improve success rates. Recent studies have shown improved clinical outcomes with use of regional ablation index (AI) targets for PVI.
View Article and Find Full Text PDFObjectives: The goal of this study was to determine whether a strategy of early re-isolation of pulmonary vein (PV) reconnection in all patients, regardless of symptoms, would reduce the recurrence of atrial fibrillation (AF) and improve quality of life.
Background: Lasting pulmonary vein isolation (PVI) remains elusive. PV reconnection is strongly linked to the recurrence of arrhythmia.
Introduction: The ConfiDENSE™ module (Carto3 v4) allows rapid annotation of endocardial electrograms acquired by multielectrode (ME) mapping. However, its accuracy in assessing atrial voltages is unknown.
Methods And Results: Two ConfiDENSE™ left atrial voltage maps were created during continuous pacing in 20 patients undergoing catheter ablation for persistent AF using a ME lasso catheter and a contact force (CF) sensing ablation catheter.
Background: Cardiomyopathy patients are at risk of sudden death, typically from scar-related abnormalities of electrical activation that promote ventricular tachyarrhythmias. Abnormal intra-QRS peaks may provide a measure of altered activation. We hypothesized that quantification of such QRS peaks (QRSp) in high-resolution ECGs would predict arrhythmic events in implantable cardioverter-defibrillator (ICD)-eligible cardiomyopathy patients.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
September 2017
Aims: Late recovery of ablated tissue leading to reconnection of pulmonary veins remains common following radiofrequency catheter ablation for AF. Ablation Index (AI), a novel ablation quality marker, incorporates contact force (CF), time, and power in a weighted formula. We hypothesized that prospective use of our previously published derived AI targets would result in better outcomes when compared to CF-guided ablation.
View Article and Find Full Text PDFObjectives: The study sought to localize focal sources (FS) during atrial fibrillation (AF) using periodic component analysis (PiCA) and QS unipolar electrogram (EGM) morphology based on the assumption that periodic activation with centrifugal propagation is inherent to a FS.
Background: The localization of FS maintaining AF remains challenging, due to limitations in conventional time-frequency domain analysis. This is relevant to identifying targets for AF substrate ablation.
Objectives: To address the limited long-term outcome data for catheter ablation (CA) of persistent atrial fibrillation (PeAF), we analysed consecutive ablations performed at our centre from 1 January 2008 to 31 December 2010 and followed patients prospectively until January 2014.
Methods: Both arrhythmia recurrence and symptom relief were assessed. Follow-up data were collected from hospital records, supplemented by data from general practitioners and referring hospitals.
Aims: Force-Time Integral (FTI) is commonly used as a marker of ablation lesion quality during pulmonary vein isolation (PVI), but does not incorporate power. Ablation Index (AI) is a novel lesion quality marker that utilizes contact force, time, and power in a weighted formula. Furthermore, only a single FTI target value has been suggested despite regional variation in left atrial wall thickness.
View Article and Find Full Text PDFBackground: Nonsustained ventricular tachycardia (NSVT) detected by ambulatory Holter (Holter NSVT) is a major risk factor for sudden cardiac death in hypertrophic cardiomyopathy (HCM). We hypothesized that the prognostic utility of Holter NSVT in HCM would improve with prolonged monitoring and a higher heart rate cut-off for detection.
Methods: We enrolled 60 patients (44 ± 14 years) with HCM, who had a prophylactic implantable cardioverter defibrillator (ICD).
Indian Pacing Electrophysiol J
March 2016
The right atrial appendage can be the origin of focal atrial tachycardias. Their ablation can be challenging owing to the complexity of the appendage anatomy. To our knowledge, we describe the first successful solid tip cryoablation of a focal tachycardia within the right atrial appendage in a patient presenting with tachycardia-induced cardiomyopathy.
View Article and Find Full Text PDF