Axial resolution is one of the most important characteristics of a microscope. In all microscopes, a high axial resolution is desired in order to discriminate information efficiently along the longitudinal direction. However, when studying thick samples that do not contain laterally overlapping information, a low axial resolution is desirable, as information from multiple planes can be recorded simultaneously from a single camera shot instead of plane-by-plane mechanical refocusing.
View Article and Find Full Text PDFUltra-short 230 fs laser pulses of 515 nm wavelength were tightly focused into 700 nm focal spots and utilised in opening ∼400 nm nano-holes in a Cr etch mask that was tens-of-nm thick. The ablation threshold was found to be 2.3 nJ/pulse, double that of plain silicon.
View Article and Find Full Text PDFPhase imaging of biochemical samples has been demonstrated for the first time at the Infrared Microspectroscopy (IRM) beamline of the Australian Synchrotron using the usually discarded near-IR (NIR) region of the synchrotron-IR beam. The synchrotron-IR beam at the Australian Synchrotron IRM beamline has a unique fork shaped intensity distribution as a result of the gold coated extraction mirror shape, which includes a central slit for rejection of the intense X-ray beam. The resulting beam configuration makes any imaging task challenging.
View Article and Find Full Text PDFNanomaterials (Basel)
November 2022
For constructing optical and electrical micro-devices, the deposition/printing of materials with sub-1 μm precision and size (cross-section) is required. Crystalline c-ITO (indium tin oxide) nanostructures were patterned on glass with sufficient precision to form 20-50 nm gaps between individual disks or lines of ∼250 nm diameter or width. The absorbed energy density [J/cm3] followed a second-order dependence on pulse energy.
View Article and Find Full Text PDFMaterials (Basel)
November 2022
The controlled deposition of CoCrFeNiMo0.2 high-entropy alloy (HEA) microparticles was achieved by using laser-induced forward transfer (LIFT). Ultra-short laser pulses of 230 fs of 515 nm wavelength were tightly focused into ∼2.
View Article and Find Full Text PDFMicromachines (Basel)
July 2022
THz band-pass filters were fabricated by femtosecond-laser ablation of 25-μm-thick micro-foils of stainless steel and Kapton film, which were subsequently metal coated with a ∼70 nm film, closely matching the skin depth at the used THz spectral window. Their spectral performance was tested in transmission and reflection modes at the Australian Synchrotron's THz beamline. A 25-μm-thick Kapton film performed as a Fabry-Pérot etalon with a free spectral range (FSR) of 119 cm-1, high finesse Fc≈17, and was tuneable over ∼10μm (at ∼5 THz band) with β=30∘ tilt.
View Article and Find Full Text PDFPolarisation analysis of light-matter interactions established for propagating optical far-fields is now extended into an evanescent field as demonstrated in this study using an attenuated total reflection (ATR) setup and a synchrotron source at THz frequencies. Scalar intensity , rather than a vector -field, is used for absorbance analysis of the s- and p-components of the linearly polarised incident light. Absorption and phase changes induced by the sample and detected at the transmission port of the ATR accessory revealed previously non-accessible anisotropy in the absorption-dispersion properties of the sample probed by the evanescent optical near-field.
View Article and Find Full Text PDFNanomaterials (Basel)
November 2021
Polarisation analysis in the mid-infrared fingerprint region was carried out on thin (∼1 μm) Si and SiO films evaporated via glancing angle deposition (GLAD) method at 70∘ to the normal. Synchrotron-based infrared microspectroscopic measurements were carried out on the Infrared Microspectroscopy (IRM) beamline at Australian Synchrotron. Specific absorption bands, particularly Si-O-Si stretching vibration, was found to follow the angular dependence of ∼cos2θ, consistent with the absorption anisotropy.
View Article and Find Full Text PDFThe precise and effective generation of micron-sized droplets is one of the most common and important issues for droplet-based microfluidics. Active droplet generation makes use of additional energy input in promoting interfacial instabilities for droplet generation. Here, we report a new technique for the active generation of femtoliter droplets in microfluidic systems using confined interfacial vibration (CIV).
View Article and Find Full Text PDF