Publications by authors named "Mohd Marsin Sanagi"

The presence of heavy metal and radionuclides in water bodies has been a long-lasting environmental problem which results in many undesirable consequences. In this framework, the biosorption process, which uses inexpensive and naturally produced material such as alginate, is an alternative technology in the environmental remediation. This review provides relevant and recent literature regarding the application of alginate and its derivatives on removal of various heavy metal ions and radionuclides.

View Article and Find Full Text PDF

A new crosslinked chitosan grafted with methyl methacrylate (M-CTS) adsorbent was synthesized via free radical polymerization for effective removal of Cu(II) ions from aqueous solution. Crosslinked chitosan (1 g) was grafted with 29.96 × 10 M methyl methacrylate in the presence of 2.

View Article and Find Full Text PDF

Magnetic solid phase extraction (MSPE) employing oil-palm fiber activated carbon (OPAC) modified with magnetite (FeO) and polypyrrole (OPAC-FeO-PPy) was successfully used for the determination of two organochlorine pesticides (OCPs), namely endosulfan and dieldrin in environmental water samples. Analysis was performed using gas chromatography with micro-electron capture detection (GC-μECD). The effects of three preparation variables, namely FeO:OPAC ratio, amount of pyrrole monomer, and amount of FeCl oxidant were optimized using Box-Behnken design (BBD) (R < 0.

View Article and Find Full Text PDF

A new effective adsorbent, 3-aminopropyltrimethoxysilane functionalized magnetic sporopollenin (MSp@SiONH) based silica-coated graphene oxide (GO), (GO@SiO-MSp@SiONH) was successfully synthesized and applied for the first time in the removal of hazardous Pb(II) ions from aqueous solution. The properties of the composite were characterized using Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), field emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDX) and vibrating-sample magnetometery (VSM). Evaluation of GO@SiO-MSp@SiONH adsorption performance at optimum conditions revealed that the adsorbent has a maximum adsorption capacity of 323.

View Article and Find Full Text PDF

Particular attention has been paid to capillary electrophoresis as versatile and environmentally friendly approach for enantioseparations of a wide spectrum of compounds. Cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) is a method of choice to provide effective separation toward hydrophobic and uncharged stereoisomers. The chiral discrimination of the solutes relies upon the partitioning between a given CD in the aqueous phase and micelles formed from a surfactant.

View Article and Find Full Text PDF

Grafting of crosslinked chitosan with monomer, N-vinyl-2-pyrrolidone, has been carried out to investigate its adsorption capacity toward Orange G (OG) from aqueous solutions. The adsorption performance of modified chitosan (cts(x)-g-PNVP) was examined and compared with that of the unmodified chitosan. The effects of initial pH, contact time and initial dye concentration were investigated in a batch system.

View Article and Find Full Text PDF

A novel nanocomposite of MGO-NGC, composed of magnetic Fe3O4 nanoparticles (M), graphene oxide (GO), and N-methyl-d-glucamine functionalized calix[4]arene (NGC), was synthesized and applied as an effective adsorbent for the removal of two selected pesticides, namely hexaconazole and chlorpyrifos from water samples. The adsorbent was characterized by FTIR, SEM, EDX, TEM, and XRD. The main parameters affecting the adsorption process such as adsorbent dosage, pH of sample solution, salt effect, pesticide concentration, and adsorption time were investigated.

View Article and Find Full Text PDF

This study describes a dispersive liquid-liquid microextraction combined with dispersive solid-phase extraction method based on phenyl-functionalized magnetic sorbent for the preconcentration of polycyclic aromatic hydrocarbons from environmental water, sugarcane juice, and tea samples prior to gas chromatography with mass spectrometry analysis. Several important parameters affecting the extraction efficiency were investigated thoroughly, including the mass of sorbent, type and volume of extraction solvent, extraction time, type of desorption solvent, desorption time, type and amount of salt-induced demulsifier, and sample volume. Under the optimized extraction and gas chromatography-mass spectrometric conditions, the method revealed good linearity (10-100000 ng/L) with coefficient of determination (R ) of ≥0.

View Article and Find Full Text PDF

We describe the preparation, characterization, and application of a composite film adsorbent based on blended agarose-chitosan-multiwalled carbon nanotubes for the preconcentration of selected nonsteroidal anti-inflammatory drugs in aqueous samples before determination by high performance liquid chromatography with ultraviolet detection. The composite film showed a high surface area (4.0258 m /g) and strong hydrogen bonding between the multiwalled carbon nanotubes and agarose/chitosan matrix, which prevent adsorbent deactivation and ensure long-term stability.

View Article and Find Full Text PDF

In this study, the Cu(II) and Cd(II) ions removal behavior of crosslinked chitosan beads grafted poly(methacrylamide) (abbreviated as crosslinked chitosan-g-PMAm) from single metal ion solutions was investigated. The modified chitosan beads presented a remarkable improvement in acid resistance. The batch experiments demonstrated that pH of solution played a significant role in adsorption.

View Article and Find Full Text PDF

Magnetic nanocomposites adorned with calixarene were successfully prepared by immobilizing diethanolamine functionalized -butylcalix[4]arene (DEA-Calix) onto silica-coated magnetic nanoparticles (MNPs). The synthesis, surface morphology, purity, elemental composition and thermal stability of newly prepared nanocomposites were analyzed using FT-IR spectroscopy, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDX), X-ray diffractometer (XRD), thermal gravimetric analysis (TGA) and vibrating sample magnetometer (VSM). Magnetic solid-phase adsorption (MSPA) was employed to explore the adsorption behavior of DEA-Calix-MNPs towards Pb(II) from water samples prior to its flame atomic absorption spectrometric analysis.

View Article and Find Full Text PDF

A facile dispersive-micro-solid phase extraction (D-μ-SPE) method coupled with HPLC for the analysis of selected non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed using a newly prepared magnetic sporopollenin-cyanopropyltriethoxysilane (MS-CNPrTEOS) sorbent. Sporopollenin homogenous microparticles of Lycopodium clavatum spores possessed accessible functional groups that facilitated surface modification. Simple modification was performed by functionalization with 3-cyanopropyltriethoxysilane (CNPrTEOS) and magnetite was introduced onto the biopolymer to simplify the extraction process.

View Article and Find Full Text PDF

In this study, caged calcium alginate-caged multiwalled carbon nanotubes dispersive microsolid phase extraction was described for the first time for the extraction of polycyclic aromatic hydrocarbons (PAHs) from water samples prior to gas chromatographic analysis. Fluorene, phenanthrene and fluoranthene were selected as model compounds. The caged calcium alginate-caged multiwalled carbon nanotubes was characterized by Fourier transform infrared spectroscopy, scanning electron microscopy and thermal gravimetry analyses.

View Article and Find Full Text PDF

Two-phase micro-electrodriven membrane extraction (EME) procedure for the pre-concentration of selected non-steroidal anti-inflammatory drugs (NSAIDs) in aquatic matrices was investigated. Agarose film was used as interface between donor and acceptor phase in EME which allowed for selective extraction of the analytes prior to high performance liquid chromatography-ultraviolet detection. Charged analytes were transported from basic aqueous sample solution through agarose film into 1-octanol as an acceptor phase at 9 V potential.

View Article and Find Full Text PDF

Crosslinked chitosan beads were grafted with N-vinyl-2-pyrrolidone (NVP) using ammonium persulfate (APS) as free radical initiator. Important variables on graft copolymerization such as temperature, reaction time, concentration of initiator and concentration of monomer were optimized. The results revealed optimum conditions for maximum grafting of NVP on 1g crosslinked chitosan as follows: reaction temperature, 60°C; reaction time, 2h and concentrations of APS and NVP of 2.

View Article and Find Full Text PDF

Graphene (G) modified with magnetite (FeO) and sol-gel hybrid tetraethoxysilane-methyltrimethoxysilane (TEOS-MTMOS) was used as a clean-up adsorbent in magnetic solid phase extraction (MSPE) for direct determination of acrylamide in various food samples prior to gas chromatography-mass spectrometry analysis. Good linearity (R=0.9990) was achieved for all samples using matrix-matched calibration.

View Article and Find Full Text PDF

Polypyrrole-magnetite dispersive micro-solid-phase extraction method combined with ultraviolet-visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole-magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro-solid-phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent.

View Article and Find Full Text PDF

A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite-MCM-41 at pH 12.

View Article and Find Full Text PDF

The efficiency of the extraction and removal of pollutants from food and the environment has been an important issue in analytical science. By incorporating inorganic species into an organic matrix, a new material known as an organic-inorganic hybrid material is formed. As it possesses high selectivity, permeability, and mechanical and chemical stabilities, organic-inorganic hybrid materials constitute an emerging research field and have become popular to serve as sorbents in various separaton science methods.

View Article and Find Full Text PDF

The ionic liquids (ILs) are salts with melting points below 100°C. These are called as ionic fluids, ionic melts, liquid electrolytes, fused salts, liquid salts, ionic glasses, designer solvents, green solvents and solvents of the future. These have a wide range of applications, including medical, pharmaceutical and chemical sciences.

View Article and Find Full Text PDF

The aim of this study was to investigate and apply supported ionic liquid membrane (SILM) in two-phase micro-electrodriven membrane extraction combined with high performance liquid chromatography-ultraviolet detection (HPLC-UV) for pre-concentration and determination of three selected antidepressant drugs in water samples. A thin agarose film impregnated with 1-hexyl-3-methylimidazolium hexafluorophosphate, [CMIM] [PF], was prepared and used as supported ionic liquid membrane between aqueous sample solution and acceptor phase for extraction of imipramine, amitriptyline and chlorpromazine. Under the optimized extraction conditions, the method provided good linearity in the range of 1.

View Article and Find Full Text PDF

Agarose-chitosan-immobilized octadecylsilyl-silica (C) film micro-solid phase extraction (μSPE) was developed and applied for the determination of phenanthrene (PHE) and pyrene (PYR) in chrysanthemum tea samples using high performance liquid chromatography-ultraviolet detection (HPLC-UV). The film of blended agarose and chitosan allows good dispersion of C, prevents the leaching of C during application and enhances the film mechanical stability. Important μSPE parameters were optimized including amount of sorbent loading, extraction time, desorption solvent and desorption time.

View Article and Find Full Text PDF

A new graphene-based tetraethoxysilane-methyltrimethoxysilane sol-gel hybrid magnetic nanocomposite (FeO@G-TEOS-MTMOS) was synthesised, characterized and successfully applied in magnetic solid-phase extraction (MSPE) for simultaneous analysis of polar and non-polar organophosphorus pesticides from several water samples. The FeO@G-TEOS-MTMOS nanocomposite was characterized using Fourier transform-infrared spectroscopy, energy-dispersive X-ray spectroscopy, field emission scanning electron microscopy and X-ray diffraction. Separation, determination and quantification were achieved using gas chromatography coupled with micro electron capture detector.

View Article and Find Full Text PDF

A rapid dispersive micro-solid phase extraction (D-μ-SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM-41 was used as sorbent in d-μ-SPE of the azole compounds from biological fluids. Important D-μ-SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized.

View Article and Find Full Text PDF

A new poly(methacrylamide) grafted crosslinked chitosan was prepared for removal of lead, Pb(II) ion from aqueous solution. Crosslinked chitosan, in beads form, was grafted with methacrylamide (MAm) using ammonium persulfate (APS) as free radical initiator. Evidence of grafting was determined by comparing FTIR, TGA, SEM and (13)C NMR analyses of chitosan and graft copolymer.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionfenjco97pqenriqaehra5j0vk0imi50f): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once