Publications by authors named "Mohammad Al-Amri"

Unlabelled: Perthes disease is a condition that affects walking patterns in young children due to poor blood circulation in the hip joint. Understanding the gait strategies of affected children is of great importance for an objective assessment and better management of this condition. The aim of this systematic review was to evaluate the current literature to identify gait compensation patterns in non-operative children with Perthes disease.

View Article and Find Full Text PDF

Inertial measurement units (IMUs) offer a portable and quantitative solution for clinical movement analysis. However, their application in non-specific low back pain (NSLBP) remains underexplored. This study compared the spine and pelvis kinematics obtained from IMUs between individuals with and without NSLBP and across clinical subgroups of NSLBP.

View Article and Find Full Text PDF

Purpose: To evaluate and compare the effect of accelerated aging and coffee immersion on the microhardness and gloss of a new computer-aided design and computer-aided manufacturing (CAD/CAM) hybrid material (Crystal Ultra) to those of contemporary restorative materials.

Materials And Methods: A total of 160 specimens (12 × 14 × 1 mm ± 0.05 mm) were obtained from IPS e.

View Article and Find Full Text PDF

Background: Inclined walking is a challenging task that requires active neuromuscular control to maintain stability. However, the adaptive strategies that preserve stability during inclined walking are not well understood. Investigating the effects of self-paced inclined treadmill walking on gait stability characteristics and the activation patterns of key lower limb muscles can provide insights into these strategies.

View Article and Find Full Text PDF

Wearable sensors may enable the assessment of movement in a real-world setting, but they are not yet a standard practice in the analysis of movement due to the unknown accuracy and reliability with respect to different functional activities. Here, we established the concurrent validity and test-retest reliability of accelerations and orientations measured using affordable novel sensors during squats, jumps, walking and stair ambulation. In this observational study, participants underwent three data collection sessions during one day.

View Article and Find Full Text PDF

With the growing number of people affected by osteoarthritis, wearable technology may enable the provision of care outside a traditional clinical setting and thus transform how healthcare is delivered for this patient group. Here, we mapped the available empirical evidence on the utilization of wearable technology in a real-world setting in people with knee osteoarthritis. From an analysis of 68 studies, we found that the use of accelerometers for physical activity assessment is the most prevalent mode of use of wearable technology in this population.

View Article and Find Full Text PDF

The aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The control group was a feldspathic ceramic, Vita Mark II (VM).

View Article and Find Full Text PDF

Purpose: The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment.

Materials And Methods: Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine.

View Article and Find Full Text PDF

Purpose: To investigate and compare the translucency and color stability of a newly introduced polymer-infiltrated ceramic network (PICN) material (Crystal Ultra) to those of clinically well-established restorative materials.

Materials And Methods: A total of 80 specimens measuring (12 × 14 × 1 mm ± 0.05 mm) were prepared from five CAD/CAM (IPS e.

View Article and Find Full Text PDF

Background: Movement analysis in a clinical setting is frequently restricted to observational methods to inform clinical decision making, which has limited accuracy. Fixed-site, optical, expensive movement analysis laboratories provide gold standard kinematic measurements; however, they are rarely accessed for routine clinical use. Wearable inertial measurement units (IMUs) have been demonstrated as comparable, inexpensive, and portable movement analysis toolkits.

View Article and Find Full Text PDF

Dual-task paradigms have been increasingly used to assess the interaction between cognitive demands and the control of balance and gait. The interaction between functional and cognitive demands can alter movement patterns and increase knee instability in individuals with knee conditions, such as knee anterior cruciate ligament (ACL) injury or osteoarthritis (OA). However, there is no consensus on the effects of dual-task on gait mechanics and balance in those individuals.

View Article and Find Full Text PDF

Objective: To examine functional performance differences using kinematic and kinetic analysis between participants with and without knee osteoarthritis (OA) to determine which outcomes best characterize persons with and without knee OA.

Methods: Participants with unilateral moderate knee OA (Kellgren-Lawrence grades 2 or 3) and controls without knee pain were matched for age, gender, and body mass index. Primary outcomes included temporal parameters, joint rotations and moments, and ground reaction forces assessed via 3D motion capture during walking and ascending/descending stairs.

View Article and Find Full Text PDF

Introduction: Visual feedback is an effective method to enhance postural and balance control in clinical and sports training. The aim of this study was to explore the effect of real-time visual feedback provided by a video camera on the performance of a dynamic balance test, which is the star excursion balance test in healthy subjects.

Methods: We compared the performance of the star excursion balance test using the maximum reach distance in 20 healthy participants (10 male and 10 female, 26.

View Article and Find Full Text PDF

Objective: To evaluate current evidence for the effectiveness of virtual reality (VR) interventions in improving neurocognitive performance in individuals who have sustained a traumatic brain injury (TBI).

Methods: A systematic literature search across multiple databases (PubMed, EMBASE, Web of Science) for articles of relevance. Studies were evaluated according to study design, patient cohort, VR intervention, neurocognitive parameters assessed, and outcome.

View Article and Find Full Text PDF

The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping.

View Article and Find Full Text PDF

Self-paced treadmill walking is becoming increasingly popular for the gait assessment and re-education, in both research and clinical settings. Its day-to-day repeatability is yet to be established. This study scrutinised the test-retest repeatability of key gait parameters, obtained from the Gait Real-time Analysis Interactive Lab (GRAIL) system.

View Article and Find Full Text PDF

Purpose: To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction.

Materials And Methods: Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale.

View Article and Find Full Text PDF

Purpose: It has been hypothesized that there are no effects of Expasyl and subsequent cleaning with hydrogen peroxide on polymerization of selected commonly used impression materials. Therefore, the aim of this study was to evaluate the effect of Expasyl paste on the polymerization of three impression materials with and without subsequent cleaning using 3% hydrogen peroxide (H O ).

Materials And Methods: Nine standardized stainless steel specimens were fabricated.

View Article and Find Full Text PDF

Purpose: To compare changes in clinical (bleeding on probing [BOP] and probing pocket depth [PPD]), radiographic (crestal bone loss [CBL]), and immunologic inflammatory (interleukin-1beta [IL-1β] and matrix metalloproteinase-9 [MMP-9]) parameters around crestally and subcrestally placed dental implants 5 years after implant placement.

Materials And Methods: Fifty-two patients were divided into 2 groups: group 1 (n = 27): patients with single implants placed approximately 2 mm below the alveolar crest; group 2 (n = 25): patients with single implants placed at bone level. In both groups, peri-implant BOP, PPD, and CBL were measured, and levels of IL-1β and MMP-9 were determined in duplicates using enzyme-linked immunosorbent assay.

View Article and Find Full Text PDF

Purpose: To compare bleeding on probing (BoP), probing depth (PD; ≥ 4 mm), radiographic (peri-implant crestal bone loss [CBL]), and immunologic inflammatory (interleukin-1beta [IL-1β] and matrix metalloproteinase-9 [MMP-9]) parameters around dental implants with cement-retained (CR) and screw-retained (SR) implant-supported crowns.

Materials And Methods: Based on the mode of retention of the restoration, 51 patients were divided into two groups: Group 1, consisting of 26 single implants restored with CR crowns, and Group 2, consisting of 25 single implants restored with SR crowns. Peri-implant BoP, PD, and CBL were scored, and levels of IL-1β and MMP-9 in the peri-implant crevicular fluid (PICF) in both groups were measured in duplicate using enzyme-linked immunosorbent assay.

View Article and Find Full Text PDF

Statement Of Problem: The detrimental effect of extruded excess cement on peri-implant tissue has been well documented. Although several techniques have been proposed to reduce this effect by decreasing the amount of extruded cement, how the space size of the abutment screw access channel (SAC) affects the amount of extruded cement and marginal accuracy is unclear.

Purpose: The purpose of this in vitro study was to evaluate the effect of the size of the unfilled space of the abutment SAC on the amount of extruded excess cement and the marginal accuracy of zirconia copings.

View Article and Find Full Text PDF

Purpose: In indexed literature, a systematic review of the efficacy of statins in enhancing osseointegration is lacking. The aim of this systematic review was to assess the efficacy of local and systemic statin delivery on the osseointegration of implants.

Materials And Methods: To address the focused question, "Does local and systemic statin delivery affect osseointegration around implants?", indexed databases were searched from 1965 through November 2015 using various keywords.

View Article and Find Full Text PDF

Introduction: The purpose of this study was to compare the oral health status and its effect on the oral health-related quality of life (OHRQoL) of hospitalized and nonhospitalized elderly patients in a single community. The null hypothesis for the study states that there is no difference in the oral health status and OHRQoL between hospitalized and nonhospitalized elderly patients.

Materials And Methods: This study was conducted at the King Khalid Hospital and College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia.

View Article and Find Full Text PDF

Zirconium (Zr) has been found to have comparable characteristics to titanium with a favorable modulus of elasticity. In addition, the release of Zr-ions of a Zr implant is supposed to further increase the bone-to-implant response. Therefore, the objective of this study is to compare the bone contact to Zr and Ti implants in the femoral trabecular bone of rabbits.

View Article and Find Full Text PDF