Water Sci Technol
October 2001
Up to now, within the design/retrofit of wastewater treatment plants (WWTPs), deterministic models were used to evaluate different scenarios on their merits in terms of effluent compliance. This paper describes an approach in which a Monte Carlo engine is coupled to a deterministic treatment plant model, followed by risk interpretation in the form of concentration-duration-frequency (cdf) curves of norm exceedance. The combination of probabilistic modelling techniques with the currently available deterministic models allows to determine the probability of exceeding the effluent limits of a WWTP.
View Article and Find Full Text PDFPurge-and-trap combined with high-resolution gas chromatography and detection by mass spectrometry was evaluated for the analysis of 27 volatile organic compounds (VOCs) in marine water samples down to ng l(-1) concentration levels. The target compounds included chlorinated alkanes and alkenes, monocyclic aromatic hydrocarbons and chlorinated monocyclic aromatic hydrocarbons and covered a wide range of VOCs of environmental interest. Limits of detection ranged from 0.