Background: The screw-in effect is a tendency of a nickel-titanium (NiTi) rotary endodontic file to be pulled into the canal, which can result in a sudden increase in stress leading to instrument fracture, and over-instrumentation beyond the apex. To reduce screw-in force, repeated up-and-down movements are recommended to distribute flexural stress during instrumentation, especially in curved and constricted canals. However, there is no consensus on the optimal number of repetitions.
View Article and Find Full Text PDFBackground/purpose: Temperature-dependent phase compositional changes influence the mechanical properties of heat-treated nickel-titanium (NiTi) rotary instruments. This study evaluated the phase composition, bending properties, and cyclic fatigue resistance of HyFlex EDM NiTi rotary instruments against differently heat-treated and non-heat-treated NiTi instruments at body temperature (BT).
Materials And Methods: HyFlex EDM OneFile (EDM) instruments, heat-treated HyFlex CM (CM) and Twisted File (TF) instruments, and non-heat-treated K3 instruments (size #25/.
The aim of this study was to evaluate how preset torque settings influence the torque, vertical force, and root canal-centering ability of ProGlider and ProTaper NEXT nickel-titanium rotary instruments in canals with different curvature locations. Based on micro-computed tomography, mesial roots of human mandibular molars (25°-40° curvature) were allocated to the apical curvature (apical 1-5 mm) or the middle curvature (apical 5-9 mm) groups, and mandibular incisors (curvature <5°) to the straight canal group. Each group was subjected to automated instrumentation and torque/force measurement with the preset torque of 1, 2.
View Article and Find Full Text PDFBackground/purpose: The glide path instruments are the introductory instruments into the canals; thus, they should be durable enough to withstand torsional stress/screw-in force. This study aimed to investigate the torque and screw-in force of TruNatomy Glider (TN), ProGLIDER (PG), Hyflex EDM (EDM) and Dent Craft RE (RE) glide path instruments in single- and double-curved canals.
Materials And Methods: Each instrument brand was divided into two groups (n = 7 each) according to the canal configuration.
Background/purpose: Using conventional approach to examine stationary torque of nickel-titanium rotary instruments contradicts the clinical condition, and its validity for motions involving clockwise and counterclockwise rotations is questionable. This study aimed to examine the effect of different kinematics on the torsional behavior using a JIZAI instrument (#25/.04) under stationary/dynamic test conditions using clinical torque limit settings.
View Article and Find Full Text PDFBackground: To evaluate the effect of pecking motions with faster upward speed on the dynamic cyclic fatigue resistance of nickel-titanium rotary instruments with different metallurgy.
Methods: Forty each of ProTaper Universal F3 (PTU) and ProTaper Gold F3 (PTG) instruments (size #30/.09) were equally divided into four groups.
Introduction: This study aimed to analyze torque/force generation and transportation in double-curved canals instrumented with 3 types of glide path files using optimum glide path (OGP) motion in comparison with continuous rotation.
Methods: Sixty simulated double-curved canals were prepared with #10/0.05 or #15/0.