Emmprin is a transmembrane glycoprotein known as a matrix metalloproteinase inducer and is highly up-regulated in malignant cancer cells. The monocarboxylate transporters (MCTs) are responsible for H(+)-linked transport of monocarboxylates across the cell membrane. It was recently demonstrated that proper plasma membrane localization and activity of MCTs require the presence of emmprin as a chaperone and that MCT-1 also acts as chaperone for emmprin.
View Article and Find Full Text PDFThe purpose of this work is to retrospectively analyze the effect of the inhomogeneity correction using clinically treated plan of stage III non-small-cell lung cancer within multiple institutions in Japan. Twenty-five patients among five facilities of radiation therapy were registered for this study. The isocenter dose or D(95) of PTV or other important values were compared with and without an inhomogeneity correction using model-based algorithm.
View Article and Find Full Text PDFPrimary sarcoma of the fallopian tube is a very rare neoplasm. We report the case of a 69-year-old woman affected with leiomyosarcoma of the left fallopian tube. Her chief complaint was lower abdominal pain.
View Article and Find Full Text PDFIntroduction: A high incidence of endometrial K-ras mutations has been reported in tamoxifen (TAM)-treated patients with breast cancer. We examined the changes in the frequency of the endometrial K-ras mutations after the cessation of TAM treatment.
Methods: DNA was extracted from fresh cytological or polypectomy samples of the endometrium in 28 patients who had undergone TAM treatment of breast cancer.
The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k(pl) for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials in the range of 4-18 MV photon beams. For electron beams, a depth-scaling factor c(pl) and a chamber-dependent fluence correction factor h(pl) for both phantoms were also calculated in combination with NACP-02 and Roos plane-parallel ionization chambers in the range of 4-18 MeV.
View Article and Find Full Text PDFObjective: To report a rare uterine anomaly consisting of a normal uterus, a double cervix, and a double vagina.
Design: Case report.
Setting: University hospital.