Practical techniques to identify heat routes at the nanoscale are required for the thermal control of microelectronic, thermoelectric, and photonic devices. Nanoscale thermometry using various approaches has been extensively investigated, yet a reliable method has not been finalized. We developed an original technique using thermal waves induced by a pulsed convergent electron beam in a scanning transmission electron microscopy (STEM) mode at room temperature.
View Article and Find Full Text PDFIntroducing magnetic order into a topological insulator (TI) system has attracted much attention with an expectation of realizing exotic phenomena such as the quantum anomalous Hall effect (QAHE) and axion insulator states. The magnetic proximity effect (MPE) is one of the promising schemes to induce the magnetic order on the surface of a TI without introducing disorder accompanied by doping magnetic impurities in the TI. In this study, we investigate the MPE at the interface of a heterostructure consisting of the topological crystalline insulator (TCI) SnTe and Fe by employing polarized neutron reflectometry.
View Article and Find Full Text PDFCarbon nanotubes have a helical structure wherein the chirality determines whether they are metallic or semiconducting. Using in situ transmission electron microscopy, we applied heating and mechanical strain to alter the local chirality and thereby control the electronic properties of individual single-wall carbon nanotubes. A transition trend toward a larger chiral angle region was observed and explained in terms of orientation-dependent dislocation formation energy.
View Article and Find Full Text PDFA material with a low work function exhibiting field-emission of electrons has long been sought as an ideal point electron source to generate a coherent electron beam with high brightness, long service life, low energy spread, and especially stable emission current. The quality and performance of the electron source are now becoming limiting factors for further improving the spatial resolution and analytical capabilities of the electron microscope. While tungsten (W) is still the only material of choice as a practically usable field emission filament since it was identified more than six decades ago, its electron optical performance remains unsatisfactory, especially the poor emission stability (>5% per hour), rapid current decay (20% in 10 hours), and relatively large energy spread (0.
View Article and Find Full Text PDFA phase retrieval technique based on a transport of intensity equation (TIE) is one of the defocus series reconstruction techniques in microscopy. Since it does not require any dedicated devices like a biprism, and only three defocus images are enough to retrieve phase information, it has been applied to observe magnetic fields, magnetic domains, electrostatic potentials and strains. It is also used to improve image resolution by correcting spherical aberration.
View Article and Find Full Text PDFSci Technol Adv Mater
August 2020
We propose a new theoretical kinetic model of strength recovery by oxidation-induced self-healing of surface cracks in composites containing a healing agent (HA). The kinetics is a key parameter in the design of structural components that can self-heal the damage done in service. Based on three-dimensional (3D) observations of crack-gap filling, two crack-gap filling models, i.
View Article and Find Full Text PDFA single hafnium carbide (HfC) nanowire field-induced electron emitter with a sharp tip apex is fabricated by Pt deposition and focused ion beam (FIB) milling. The structure of the electron emitter is characterized by scanning transmission electron microscopy (STEM) and atom probe tomography (APT). The HfC nanowire is single-crystalline with a thin oxide layer on its tip surface.
View Article and Find Full Text PDFBoron nitride nanotubes (BNNTs) are promising for mechanical applications owing to the high modulus, high strength, and inert chemical nature. However, up to now, precise evaluation of their elastic properties and their relation to defects have not been experimentally established. Herein, the intrinsic elastic modulus of BNNTs and its dependence on intrinsic and deliberately irradiation-induced extrinsic defects have been studied via an electric-field-induced high-order resonance technique inside a high-resolution transmission electron microscope (HRTEM).
View Article and Find Full Text PDFMechanical resonators have wide applications in sensing bio-chemical substances, and provide an accurate method to measure the intrinsic elastic properties of oscillating materials. A high resonance order with high response frequency and a small resonator mass are critical for enhancing the sensitivity and precision. Here, we report on the realization and direct observation of high-order and high-frequency silicon nanowire (Si NW) resonators.
View Article and Find Full Text PDFPhysical properties of carbon nanotubes (CNTs) are closely related to the atomic structure, i.e. the chirality.
View Article and Find Full Text PDFSelf-crack-healing by oxidation of a pre-incorporated healing agent is an essential property of high-temperature structural ceramics for components with stringent safety requirements, such as turbine blades in aircraft engines. Here, we report a new approach for a self-healing design containing a 3D network of a healing activator, based on insight gained by clarifying the healing mechanism. We demonstrate that addition of a small amount of an activator, typically doped MnO localised on the fracture path, selected by appropriate thermodynamic calculation significantly accelerates healing by >6,000 times and significantly lowers the required reaction temperature.
View Article and Find Full Text PDFWe demonstrate that high resolution transmission electron microscopy (HRTEM) paired with light illumination of a sample and its electrical probing can be utilized for the in situ study of initiated photocurrents in free-standing nanowires. Morphology, phase and crystallographic information from numerous individual CdS nanowires is obtained simultaneously with photocurrent measurements. Our results indicate that elastically bent CdS nanowires possessing a wurtzite structure show statistically unchanged values of ON/OFF (photocurrent/dark current) ratios.
View Article and Find Full Text PDFMicroparticles of radioactive cesium (Cs)-bearing silicate glass emitted from the Fukushima Daiichi nuclear power plant were investigated mainly using state-of-the-art energy-dispersive X-ray spectroscopy in scanning transmission electron microscopes. Precise elemental maps of the particles were obtained using double silicon drift detectors with a large collection angle of X-rays, and qualitative elemental analysis was performed using high-resolution X-ray spectroscopy with a microcalorimetry detector. Beside the substantial elements (O, Si, Cl, K, Fe, Zn, Rb, Sn and Cs) as previously reported, Mn and Ba were also common, though their amounts were small.
View Article and Find Full Text PDFMicroparticles containing substantial amounts of radiocesium collected from the ground in Fukushima were investigated mainly by transmission electron microscopy (TEM) and X-ray microanalysis with scanning TEM (STEM). Particles of around 2 μm in diameter are basically silicate glass containing Fe and Zn as transition metals, Cs, Rb and K as alkali ions, and Sn as substantial elements. These elements are homogeneously distributed in the glass except Cs which has a concentration gradient, increasing from center to surface.
View Article and Find Full Text PDFHow to concentrate target molecules on the surface of a SERS substrate is a key problem in the practical application of SERS. Herein, we designed for the first time a pollutant capturing surface enhanced Raman spectroscopy (SERS) substrate, namely porous BN microfibers uniformly decorated with Ag nanoparticles, in which the BN microfibers adsorb pollutants, while the Ag nanoparticles provide SERS activity. This SERS substrate captures pollutants from an aqueous solution completely and accumulates them all on its surface without introducing noise signals.
View Article and Find Full Text PDFWe developed an original method of in situ nanoscale characterization of thermal resistance utilizing a high-resolution transmission electron microscope (HRTEM). The focused electron beam of the HRTEM was used as a contact-free heat source and a piezo-movable nanothermocouple was developed as a thermal detector. This method has a high flexibility of supplying thermal-flux directions for nano/microscale thermal conductivity analysis, and is a powerful way to probe the thermal properties of complex or composite materials.
View Article and Find Full Text PDFThe hollow core of a carbon nanotube (CNT) provides a unique opportunity to explore the physics, chemistry, biology, and metallurgy of different materials confined in such nanospace. Here, we investigate the nonequilibrium metallurgical processes taking place inside CNTs by in situ transmission electron microscopy using CNTs as nanoscale resistively heated crucibles having encapsulated metal nanowires/crystals in their channels. Because of nanometer size of the system and intimate contact between the CNTs and confined metals, an efficient heat transfer and high cooling rates (∼10(13) K/s) were achieved as a result of a flash bias pulse followed by system natural quenching, leading to the formation of disordered amorphous-like structures in iron, cobalt, and gold.
View Article and Find Full Text PDFACS Appl Mater Interfaces
October 2014
An oleic acid-coated Fe2.7Co0.3O4 nanocrystal (NC) self-assembled film was fabricated via drop casting of colloidal particles onto a three-terminal electrode/MgO substrate.
View Article and Find Full Text PDFThree-dimensional graphene architectures in the macroworld can in principle maintain all the extraordinary nanoscale properties of individual graphene flakes. However, current 3D graphene products suffer from poor electrical conductivity, low surface area and insufficient mechanical strength/elasticity; the interconnected self-supported reproducible 3D graphenes remain unavailable. Here we report a sugar-blowing approach based on a polymeric predecessor to synthesize a 3D graphene bubble network.
View Article and Find Full Text PDFAn oleic acid-coated Fe3O4 nanocrystal self-assembled film was fabricated via drop casting of colloidal particles on a SiO2/Si substrate. The film exhibited bifurcation of the zero-field-cooled and field-cooled magnetizations around 250 K. The nonlinear current-voltage (I-V) characteristics between the source and drain electrodes in both zero and non-zero magnetic fields (H) were observed above and below the bifurcation temperature.
View Article and Find Full Text PDFMechanical properties and fracture behaviors of multiwalled WS2 nanotubes produced by large scale fluidized bed method were investigated under uniaxial tension using in situ transmission electron microscopy probing; these were directly correlated to the nanotube atomic structures. The tubes with the average outer diameter ∼40 nm sustained tensile force of ∼2949 nN and revealed fracture strength of ∼11.8 GPa.
View Article and Find Full Text PDFIn this review, a non-standard application of high-resolution transmission electron microscope (HRTEM), namely the creation of so-called NanoLaboratory for the nanomaterial property studies within its pole piece, is presented. The most modern research trends with respect to nanotube, graphene and nanowire, as well as electrical, mechanical and electromechanical properties are demonstrated. In addition, the unique possibilities of modeling real technological processes inside HRTEM, for example, the performance of Li-ion batteries, are illustrated.
View Article and Find Full Text PDFPseudobinary solid-solution semiconductor nanowires made of (GaP)(1-x)(ZnS)(x), (ZnS)(1-x)(GaP)(x) and (GaN)(1-x)(ZnO)(x) were synthesized based on an elaborative compositional, structural, and synthetic designs. Using analytical high-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (EDS), we confirmed that the structure uniformity and a lattice match between the two constituting binary components play the key roles in the formation of quaternary solid-solution nanostructures. Electrical transport measurements on individual GaP and (GaP)(1-x)(ZnS)(x) nanowires indicated that a slight invasion of ZnS in the GaP host could lead to the abrupt resistance increase, resulting in the semiconductor-to-insulator transition.
View Article and Find Full Text PDFThe low-energy Ar-ion milling method was used to prepare ultrathin specimens for transmission electron microscope observation. The samples were thinned initially by a usual focused ion beam technique or typical Ar-ion milling with a high energy of 2-10 keV and were thinned additionally by an Ar-ion beam with an energy less than 1 keV, typically 500-900 eV. This low-energy ion beam was scanned over the specimen, and secondary electrons induced by the ion beam could be detected to form secondary electron images with a resolution of a few micrometre.
View Article and Find Full Text PDF