Publications by authors named "Mirza-Rustum Baig"

Sterilization is required for any biomedical device intended to be used in contact with the human body. Several studies have reported alterations in the bulk and surface properties of such devices after repeated sterilization cycles. These surface modifications may influence other clinical parameters.

View Article and Find Full Text PDF

Fracture resistance is an important parameter used to predict the performance of indirect dental restorations. The purpose of this in vitro study was to assess the fracture load of posterior milled nanoceramic crowns, in comparison with the lithium disilicate crowns, after fatigue loading, for two different restoration occlusal thicknesses. Forty test metal dies were fabricated by duplicating a master metal model consisting of an anatomic abutment preparation of the maxillary first premolar for a single crown.

View Article and Find Full Text PDF

Statement Of Problem: The connector height and retainer occlusal thickness of fixed partial dentures (FPDs) may affect restoration longevity.

Purpose: The purpose of this in vitro study was to determine and compare the fracture resistance of 4-unit monolithic 5% yttria tetragonal zirconia polycrystal (5Y-TZP) FPDs made with different connector heights and retainer occlusal thicknesses after thermomechanical aging.

Material And Methods: Forty test metal dies were duplicated from a master metal die containing 2 anatomic abutment preparations of the mandibular right first premolar and second molar for a 4-unit FPD.

View Article and Find Full Text PDF

Immediate implant placement is well-known science and treatment in implant dentistry. It is a multitasking treatment consisting of surgical, prosthodontic, and periodontal aspects, implemented to obtain long-term clinically esthetic and functioning prosthesis. Immediate placement enables clinicians to reduce the number of surgical steps and shorter treatment duration.

View Article and Find Full Text PDF

Purpose: To synthesise and characterise nanosilver sodium fluoride (NSSF) and assess the effect of applying this formulation in vitro on artificially demineralised root dentin lesions, compared with the application of silver diamine fluoride (SDF), sodium fluoride (NAF) or no treatment, in terms of mechanical, chemical and ultrastructural properties.

Materials And Methods: NSSF was prepared using 0.5 wt% chitosan solution.

View Article and Find Full Text PDF

Objectives: The objective of this retrospective clinical study was to investigate the survival rates and complications of implant (I)-retained or tooth-implant (TI)-retained prostheses and abutments (teeth, implants) over a mean observation period of 11.26 years. The study also aimed to analyze the differences and complication rates between implant-retained double crown removable dental prostheses (I-DC-RDPs) versus tooth-implant-retained double crown removable dental prostheses (TI-DC-RDPs).

View Article and Find Full Text PDF

Edentulism is considered a poor health condition and may compromise the quality of life. Prosthodontic replacement of missing teeth results in significant improvement of oral functions. Treating a patient with Down syndrome can pose clinical challenges in handling the emotional aspect as well as in rendering treatment.

View Article and Find Full Text PDF

Objectives: The aim of this retrospective clinical study was to evaluate the survival and the occurrence of technical and biological complications in bi-layered zirconia-based (Zi) single crown and 3-unit fixed dental prostheses (FDPs). Also, the study aimed to analyze the effects of tooth vitality (vital versus non-vital), abutment location (anterior versus posterior), and luting cement (self-adhesive resin versus resin-reinforced glass ionomer) on clinical outcomes.

Methods: A total of 147 prostheses (in 94 patients) placed by undergraduate dental students in a university dental center during the period 2015-2021 were examined clinically using modified United States Public Health Service (USPHS) and California Dental Association (CDA) criteria.

View Article and Find Full Text PDF

Statement Of Problem: Marginal integrity and internal adaptation are key to the long-term success of porcelain laminate veneers. Evidence for their marginal and internal fit is unclear, and the factors affecting such fit have not been identified.

Purpose: The purpose of this systematic review and meta-analysis was to summarize the scientific literature assessing the effects of various parameters on the marginal and internal fit of porcelain laminate veneers.

View Article and Find Full Text PDF

A polymer-infiltrated ceramic network (PICN) material has recently been introduced for dental use and evidence is developing regarding the fit accuracy of such crowns with different preparation designs. The aim of this in vitro study was to evaluate the precision of fit of machined monolithic PICN single crowns in comparison to lithium disilicate crowns in terms of marginal gap, internal gap, and absolute marginal discrepancies. A secondary aim was to assess the effect of finish line configuration on the fit accuracy of crowns made from the two materials.

View Article and Find Full Text PDF

Fit accuracy and fracture strength of milled monolithic zirconia (Zi) and zirconia-reinforced lithium silicate (ZLS) crowns are important parameters determining the success of these restorations. This study aimed to evaluate and compare the marginal and internal fit of monolithic Zi and ZLS crowns, along with the fracture load, with and without mechanical aging. Thirty-two stone dies acquired from a customized master metal molar die were scanned, and ceramic crowns (16 Zi Ceramill Zolid HT and 16 ZLS Vita Suprinity) were designed and milled.

View Article and Find Full Text PDF

Purpose: To evaluate the marginal and internal fit of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) ZLS (Vita Suprinity) glass ceramic porcelain laminate veneers (PLVs), in terms of marginal and internal gap widths, in comparison to monolithic lithium disilicate (LDS) [IPS e.max CAD] CAD/CAM veneers, and, also, to analyze the effect of incisal preparation designs (butt joint and chamfer), on the marginal and internal fit accuracy.

Materials And Methods: Forty dental stone dies poured from impressions made of two master metal dies with different incisal preparation designs were scanned to produce digital models.

View Article and Find Full Text PDF
Article Synopsis
  • Guided tissue regeneration (GTR) membranes aim to treat chronic periodontal lesions by regenerating lost connection in the gums, with new designs focusing on bioactive membranes made from biopolymers and bioceramics like chitosan and hydroxyapatite.
  • A study developed a GTR membrane with a specific ratio of chitosan to hydroxyapatite, testing various characteristics including molecular weight, mechanical strength, and cytotoxicity using human cells.
  • Results showed that membranes with medium molecular weight had better swelling and degradation properties, while low molecular weight membranes had higher cell viability, suggesting this new bilayer design could be promising for further biomedical use.
View Article and Find Full Text PDF

Purpose: To evaluate the marginal fit of zirconia (Zi) CAD/CAM crowns in terms of gap and overhang compared to lithium disilicate (LDS) computer-aided design crowns, as well as the effect of finish line design on marginal accuracy.

Materials And Methods: Stone dies were acquired from two master metal dies (n = 20 each) with two different finish lines and were scanned to produce digital models. Ceramic crowns (ZS-Ronde Zi, KaVo and IPS e.

View Article and Find Full Text PDF

Objectives: To assess the fit of PRDP frameworks fabricated using alginate as a final impression material in metal stock trays, in terms of number of fabricated frameworks needed until realization of clinically adequate fit. Also, any association of framework fit achieved with its design features, namely major connector design, and numbers of guide plates and occlusal/incisal rests was investigated.

Methods: 147 partially dentate patients were provided with Co-Cr PRDPs, in single or both arches, by undergraduate dental students.

View Article and Find Full Text PDF

Objectives: To systematically review and evaluate the effects of different types of attachments, implant numbers and loading protocols on the peri-implant mucosa of implant-supported overdentures (ISODs).

Background: The impact of peri-implant tissue health on the ISOD treatment outcome is unclear, and current evidence is inadequate on this aspect.

Materials And Methods: A systematic literature search for randomised controlled trials or prospective studies was conducted in indexed databases from 1995 to April 2020.

View Article and Find Full Text PDF

Purpose: To prospectively evaluate the effects of impression material, impression tray type, and partially dentate arch classification on the accuracy of fit of partial removable dental prostheses (PRDP) cobalt-chromium (Co-Cr) frameworks, as inferred from the number of fabricated frameworks required for achievement of acceptable fit.

Materials And Methods: A total of 103 partially dentate patients provided with Co-Cr PRDP treatment for one or both arches (n = 142) by undergraduate dental students were clinically assessed by two examiners at the metal framework try-in stage, and the relevant data were recorded. Statistical analyses of data were performed using factorial analysis of variance (ANOVA) to study the associations of impression material (alginate, polyvinyl siloxane [PVS]), Kennedy class, and impression tray type (stock, custom) with the number of frameworks that needed to be fabricated for each patient (α = .

View Article and Find Full Text PDF

Purpose: There are currently no clear guidelines on the reuse of metal implant impression copings and scanbodies in implant dentistry. Manufacturers generally recommend single use, which has cost and ecological implications. The objectives of this study were to examine the effect of multiple use of implant impression copings and scanbodies on the accuracy of partially dentate implant casts.

View Article and Find Full Text PDF

This invited commentary reviews the use of splinting vs nonsplinting in implant impressions.

View Article and Find Full Text PDF

Purpose: To evaluate the effects of impression material, impression tray type, and type of partial edentulism (ie, Kennedy class) on the accuracy of fit of cobalt-chromium (Co-Cr) partial removable dental prostheses (PRDP) in terms of the number of fabricated frameworks required until the attainment of adequate fit.

Materials And Methods: Electronic case documentations of 120 partially edentulous patients provided with Co-Cr PRDP treatment for one or both arches were examined. Statistical analyses of data were performed using analysis of variance and Tukey honest significant difference test to compare the relationships between the different factors and the number of frameworks that needed to be fabricated for each patient (α = .

View Article and Find Full Text PDF

Objectives: To investigate the marginal accuracy of Cerec three-dimensional (3D) all-ceramic crowns, in terms of gap and overhang, and to analyze the "operators' experience" and "cement space" effects on the marginal fit.

Method And Materials: Thirty virtual models were obtained from a metal master die by scanning by three different operators: operator 1 (novice), operator 2 (beginner), and operator 3 (expert) (n = 10). These were further divided into two subgroups of five each, based on the cement space settings: 10 μm and 20 μm.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate and compare Oral Health-Related Quality of Life (OHRQoL), denture satisfaction, and masticatory performance in edentulous patients provided with mandibular implant-supported overdentures (ISODs) retained with telescopic attachments and those of conventional complete dentures (CCDs). Peri-implant soft tissue changes were also evaluated at various intervals during a 1-year observation period.

Materials And Methods: Participating patients received new CCDs and later received two mandibular interforaminal implants and had their mandibular CCDs converted into ISODs with telescopic attachments.

View Article and Find Full Text PDF

Purpose: Because there is a paucity of clear-cut evidence regarding which materials and techniques are most accurate for complete-arch, multiple-implant impressions, the current study sought to analyze the data and draw useful conclusions based on the evidence for application in clinical practice.

Materials And Methods: Relevant studies published between 1990 and December 2012 were included in the review. The articles were located through PubMed and manually through reviewing references in the literature.

View Article and Find Full Text PDF

Background: Accurate implant impressions are critical for the achievement of passive fit of an implant prosthesis which in turn contributes to the long-term success of the implant treatment. There is inconclusive evidence on the techniques and materials used for making multi-unit implant impressions.

Objective: To evaluate the scientific data related to different aspects of multi-unit implant impression accuracy and draw useful conclusions from the review for application in clinical practice.

View Article and Find Full Text PDF

Purpose: This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions.

Materials And Methods: A reference model with six internal-connection implant replicas placed in the completely edentulous mandibular arch and connected to multi-base abutments was fabricated from heat-curing acrylic resin.

View Article and Find Full Text PDF