Publications by authors named "Mirko Doss"

Introduction: Endoscopic minimally invasive valve surgery is a promising alternative to valve surgery through median sternotomy. Our study compared the short-term outcomes of patients undergoing endoscopic minimally invasive multiple concomitant valve surgeries (MIMVS) with median sternotomy (MS).

Methods: Demographic, clinical, and procedural data of all consecutive patients who underwent multiple-valve surgeries at two institutions in Germany from March of 2017 to March of 2023 were retrospectively collected.

View Article and Find Full Text PDF

The gold standard therapy for end-stage heart failure is cardiac transplantation. However, in the face of a donor shortage, a mechanical assist device such as the left ventricular assist device HeartMate 3 (Abbott Laboratories, Abbott Park, IL, USA) serves as bridging therapy to transplantation and/or destination therapy. Current guidelines recommend anticoagulation with a vitamin K antagonist in combination with low-dose aspirin.

View Article and Find Full Text PDF

: The minimally invasive approach through left mini-thoracotomy is a promising alternative to the median sternotomy for coronary artery bypass. The aim of this study was to compare the short-term outcomes of patients undergoing minimally invasive coronary artery bypass (MIDCAB) with off-pump coronary artery bypass through sternotomy (OPCAB) for single-vessel disease. : From January 2017 to February 2023, 377 consecutive patients aged above 18 years undergoing off-pump bypass of the left anterior descending artery (LAD) with left internal thoracic artery underwent OPCAB.

View Article and Find Full Text PDF

Objectives: To overcome some of the challenges of endoscopic minimally invasive valve surgery, an automated annular suturing device has been used in aortic and mitral valve replacement surgeries. The current study investigates early clinical outcomes of patients who received aortic or mitral valve replacement with the help of the RAM® device as first experiences in minimally invasive valve surgery.

Methods: Between September 2020 and June 2023, 66 consecutive patients (mean age 61.

View Article and Find Full Text PDF

: Recently, minimally invasive access via right anterolateral mini-thoracotomy (RAMT) has been gaining popularity in cardiac surgery. This approach is also an option for surgeons performing aortic surgery. The aim of this study is to present our surgical method, highlighting the total endoscopic minimally invasive approach via RAMT for replacement of the ascending aorta (AAR) with or without involvement of the aortic root and the aortic valve.

View Article and Find Full Text PDF

A 58-year-old male underwent LVAD-Implantation after ECLS explantation. After removal of ECLS (A) transesophageal echocardiography revealed thrombus in the inferior vena cava (B) and right atrium (C). The thrombus was removed with a second pump run including RVAD-Implantation.

View Article and Find Full Text PDF

Many attempts have been made to inhibit or counteract saphenous vein graft (SVG) failure modes; however, only external support for SVGs has gained momentum in clinical utility. This study revealed the feasibility of implantation, and showed good patency out to 12 months of the novel biorestorative graft, in a challenging ovine coronary artery bypass graft model. This finding could trigger the first-in-man trial of using the novel material instead of SVG.

View Article and Find Full Text PDF

Introduction: The frozen elephant trunk technique (FET) has become routine for aortic arch and descending aortic repair. New hybrid prosthesis models are constantly being developed to increase effectiveness and durability of aortic repair. Recently, concerns were raised regarding increased post-operative bleeding using a new-generation hybrid prosthesis (E-vita OPEN NEO, CryoLife Inc.

View Article and Find Full Text PDF

The outcomes of patients with PCS and following ECMO therapy are associated with several preoperative risk factors. Our aim was to compare clinical presentation, ECMO-related data and in-hospital outcomes of patients treated with ECMO due to PCS after cardiac surgery, in regard to elective or emergent cardiac surgery procedures. Between April 2006 and October 2016, 164 consecutive patients that received VA-ECMO therapy due to PCS were identified and included in this retrospective cohort study.

View Article and Find Full Text PDF

Background And Aim: Bioprosthetic surgical aortic valve replacement (SAVR) is increasingly adopted in younger patients. We aimed to analyze mid-term follow-up data after SAVR to assess the performance of the prosthesis.

Methods: Data were collected from a single-center series of 154 patients, who underwent SAVR with a bioprosthetic heart valve with the RESILIA tissue at our Heart Centre in Siegburg.

View Article and Find Full Text PDF

Introduction: Propensity score analysis of midterm outcomes after isolated aortic valve replacement through right anterior mini-thoracotomy and partial upper sternotomy could provide information about the most beneficial minimally invasive technique for the patient based on the preoperative risk factors.

Methods: Between March 2015 and February 2021, 694 minimally invasive isolated aortic valve surgeries were performed at our institution. Among these, 441 right anterior mini-thoracotomies and 253 partial upper sternotomies were performed.

View Article and Find Full Text PDF

Left Ventricular Assist Device (LVAD) is currently implanted not only as a bridge to transplant or recovery but also as destination therapy. One factor, affecting the device performance and treatment adequacy negatively is the development of aortic valve insufficiency (AI) after the implantation. Herein, we introduce a minimally invasive partial sternotomy aortic valve replacement with an expandable bio-prosthesis in a 74-year-old LVAD patient with severe AI.

View Article and Find Full Text PDF

Infective endocarditis (IE) following mitral valve edge-to-edge repair is a rare complication with high mortality. A 91-year-old male patient was admitted to intensive care unit with sepsis due to urinary tract infection after insertion of a urinary catheter by the outpatient urologist. Two weeks ago, the patient was discharged from hospital after successful transcatheter edge-to-edge mitral valve repair (TEER) using a PASCAL Ace device.

View Article and Find Full Text PDF

Background: Despite excellent data on lowering long-term stroke and all-cause mortality rates, currently, only 25-40% of atrial fibrillation (AF) patients undergo simultaneous surgical ablation therapy (SA) during cardiac surgery. Surgeon's fear exposing their patients to an additional, unjustified, and disproportionate risk when performing SA in AF patients presenting with sinus rhythm (SR) before surgery. To clarify the influence of preoperative SR before SA for AF, we conducted a subgroup analysis of the German Cardiosurgical Atrial Fibrillation (CASE-AF) register.

View Article and Find Full Text PDF

Background: A transapical (TA) approach to transcatheter aortic valve replacement (TAVR) may be used when a transfemoral (TF) approach is not feasible. The CHANGE neo TA study evaluated patients treated in routine clinical practice via TA-TAVR with the ACURATE bioprosthetic aortic valve.

Methods And Results: This single-arm post-market study had a planned enrolment of 200 subjects; enrolment was terminated early due to declining TA-TAVR procedures at participating centers.

View Article and Find Full Text PDF

Background: Blunted left ventricular hemodynamics reflected by a low stroke volume index (SVI) ≤35 mL/m body surface area (low flow [LF]) in patients with severe aortic stenosis (AS) are associated with worse outcomes even after correction of afterload by transcatheter aortic valve implantation (TAVI). These patients can have a low or high transvalvular mean pressure gradient (MPG). We investigated the impact of the pre-interventional MPG on outcomes after TAVI.

View Article and Find Full Text PDF

Objectives: Aortic valve calcification (AVC) determined by computed tomography has emerged as a complementary measure of aortic stenosis (AS) severity and as a predictor of adverse events. Thus, AVC can guide further treatment decisions in patients with low-gradient AS (LG-AS). We compared the symptomatic and prognostic outcome of patients with low vs.

View Article and Find Full Text PDF

Aims: Patients with aortic stenosis (AS) may have concomitant heart failure (HF) that determines prognosis despite successful transcatheter aortic valve implantation (TAVI). We compared outcomes of TAVI patients with low stroke volume index (SVI) ≤35 ml/m2 body surface area in different HF classes.

Methods And Results: Patients treated by transfemoral TAVI at our center (n = 1822) were classified as 1) 'HF with preserved ejection fraction (EF)' (HFpEF, EF ≥50%), 2) 'HF with mid-range EF' (HFmrEF, EF 40-49%), or 3) 'HF with reduced EF' (HFrEF, EF <40%).

View Article and Find Full Text PDF

Recognition of bicuspid aortic valve (BAV) may be challenging in elderly patients with heavily calcified aortic valves undergoing transcatheter aortic valve replacement (TAVR). In this subset, the diagnostic value of pre-procedural echocardiography in clinical routine is unknown. From a total of 2583 patients undergoing TAVR in our center, we determined the rate of BAV detected by routine echocardiography as documented in the medical records.

View Article and Find Full Text PDF

Background: This study compared long-term outcomes of biological and mechanical mitral valve replacement (MVR) in patients requiring replacement of the mitral valve where repair was not feasible.

Methods: A single-centre registry of patients receiving MVR between 2005 and 2015 was established. Thirty-day mortality and long-term outcomes were analysed and compared.

View Article and Find Full Text PDF

Aims: We sought to compare annular versus supra-annular sizing for transcatheter aortic valve implantation (TAVI) in patients with a bicuspid aortic valve (BAV).

Methods And Results: In this retrospective single-centre analysis, we measured the aortic annulus (Ann) and intercommissural distance (ICD) on multidetector computed tomography scans in 217 BAV patients. With annular sizing being the default method for prosthesis size selection in all cases, we determined clinically relevant sizing errors and assessed the hypothetical impact of supra-annular sizing.

View Article and Find Full Text PDF

Objectives: This study sought to examine whether the prognosis of patients with severe aortic stenosis (AS) having high versus low transvalvular mean pressure gradients (MPGs) is intrinsically different after transcatheter aortic valve replacement (TAVR), even after strict matching of baseline parameters.

Background: Patients with low MPG are characterized by higher cardiovascular risk and more comorbidities than other AS patients are.

Methods: In this retrospective, single-center study involving 2,282 patients, 3 groups were derived according to the following criteria: 1) high-gradient AS (HG-AS) (MPG ≥40 mm Hg); 2) low-flow, low-gradient AS (LFLG-AS) (MPG <40 mm Hg, ejection fraction [EF] ≤40%, stroke volume index ≤35 ml/m); 3) paradoxical LFLG-AS (pLFLG-AS) (similar to LFLG-AS but with EF ≥50%).

View Article and Find Full Text PDF

Background: The ACURATE neo prosthesis is commonly implanted using introducer sheaths with inner diameters of up to 20 French. The use of only the expandable mesh component of the transGlide introducer system (Mesh) would substantially decrease the inner diameter to 13 French. We sought to assess the feasibility and safety of using Mesh for femoral access of the ACURATE neo device and to compare outcomes with patients in whom standard sheaths were used.

View Article and Find Full Text PDF

Objectives: The aim of this study was to perform a comprehensive analysis of factors that affect procedural outcomes of transcatheter aortic valve replacement using the ACURATE neo prosthesis (Symetis/Boston, Ecublens, Switzerland).

Background: Predictors of procedural outcomes using the ACURATE neo prosthesis are poorly understood.

Methods: A total of 500 patients underwent transfemoral aortic valve replacement with the ACURATE neo prosthesis.

View Article and Find Full Text PDF