Publications by authors named "Miriam J Lopez-Miranda"

Background And Objective: To describe the 6-month safety and preliminary efficacy outcomes of the use of 24-Gy radiation with intravitreal ranibizumab for patients with neovascular age-related macular degeneration (AMD).

Patients And Methods: A single treatment of a non-invasive, externally delivered low-voltage x-ray irradiation at a dose of 24 Gy was administered in one session through three locations in the inferior pars plana in a consecutive series of patients with neo-vascular AMD (treatment naïve and previously treated). Optical coherence tomography (OCT) and Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity examinations were performed at 1 week, 1 month, and monthly thereafter with quarterly fluorescein angiography.

View Article and Find Full Text PDF

Background And Objective: To describe the 6-month safety and preliminary efficacy outcomes of the use of 16-Gy radiation with intravitreal ranibizumab for patients with neovascular age-related macular degeneration (AMD).

Patients And Methods: A single treatment of a non-invasive, externally delivered low-voltage 16-Gy x-ray irradiation was administered in one session through three locations in the inferior pars plana. Optical coherence tomography (OCT) and Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity (VA) examinations were performed at 1 week, 1 month, and monthly thereafter, with quarterly fluorescein angiography (FA).

View Article and Find Full Text PDF

Background And Objective: To describe the effect of a "radiation-first" combination treatment strategy for neovascular age-related macular degeneration (AMD) with ranibizumab rescue therapy.

Patients And Methods: Non-invasive, externally delivered low-voltage x-ray irradiation at a dose of 16 Gy was given in a single session through three locations in the inferior pars plana in a consecutive series of patients with neovascular AMD. Ranibizumab was administered according to prospectively determined criteria.

View Article and Find Full Text PDF

Background: To assess the reliability of the measurements obtained with the PalmScan, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods.

Methods: Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan A2000 and Eye Cubed) using an immersion technique.

View Article and Find Full Text PDF