PLoS One
February 2024
The pulse arrival time (PAT) has been considered a surrogate measure for pulse wave velocity (PWV), although some studies have noted that this parameter is not accurate enough. Moreover, the inter-beat interval (IBI) time series obtained from successive pulse wave arrivals can be employed as a surrogate measure of the RR time series avoiding the use of electrocardiogram (ECG) signals. Pulse arrival detection is a procedure needed for both PAT and IBI measurements and depends on the proper fiducial points chosen.
View Article and Find Full Text PDFComput Methods Programs Biomed
July 2013
Fractional differintegration is used as a new tool to characterize heart rate variability time series. This paper proposes and focuses in two indexes (αc and fnQ) derived from the fractional differintegration operator. Both indexes are applied to fractional Gaussian noise (fGn) and actual RR time series in order to test their behavior.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2013
Seismocardiography is a simple and non invasive method of recording cardiac activity from the movements of the body caused by heart pumping. In this preliminary study we use a smartphone to record this acceleration and estimate the heart rate. We compare the heart rate variability parameters from the seismocardiogram and ECG reference signal.
View Article and Find Full Text PDFAn analysis of the errors due to the finite resolution of RR time series in the estimation of the approximate entropy (ApEn) is described. The quantification errors in the discrete RR time series produce considerable errors in the ApEn estimation (bias and variance) when the signal variability or the sampling frequency is low. Similar errors can be found in indices related to the quantification of recurrence plots.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
March 2007
A method for estimating the uncertainty in time-domain indices of RR time series is described. The method relies on the central limit theorem that states that the distribution of a sample average of independent samples has an uncertainty that asymptotically approaches to the sample standard deviation divided by the square root of the number of samples. Because RR time series cannot be characterized by a set of independent samples, we propose to estimate the uncertainty of indices by computing them in blocks that satisfy that the obtained partial indices are independent.
View Article and Find Full Text PDFWe analyze the radiated emissions from a low power electrosurgical unit (ESU). Measurements at a 3-meter distance are performed in order to find a suitable measurement setup intended to reproduce realistically the real working ESU behavior in a test lab. The broad-band and narrow-band characteristics of the perturbation are studied in order to address the other equipment immunity.
View Article and Find Full Text PDF