Publications by authors named "Miodrag Scepanovic"

This study aimed to compare implant stabilities between the immediate and early loaded, immediately placed bone-level tapered dental implants in the maxilla and to evaluate marginal bone loss (MBL), oral health-related quality of life (OHRQoL), and patient satisfaction at a 2-year follow-up. A pilot, prospective, randomized, controlled clinical trial was conducted on 24 maxillary failing dentition patients. The bone-level tapered implants of 12 patients were immediately loaded with temporary restorations, while the other 12 patients did not receive any kind of temporization.

View Article and Find Full Text PDF

Background: The present pilot study aimed to assess clinical and radiographic efficiencies of bovine bone substitute (BBS) merged with hyaluronic acid (HA) in peri-implantits reconstructive surgery.

Methods: Peri-implantitis (diagnosed 6.03 ± 1.

View Article and Find Full Text PDF

Objectives: To assess whether implant macrodesign parameters interacting with implant time in function (Tf) could influence the peri-implantitis occurrence.

Materials And Methods: One hundred and two patients (55.17 ± 11.

View Article and Find Full Text PDF

Objectives: The aim of this study was to evaluate the influence of artificial ageing on the retention force of original semipermanent cements, as well as the possibility of using conventional cements for semipermanent cementation with adequate modification of the cementing protocol.

Materials And Methods: Forty CoCrMo alloy crowns were divided in four groups (each group n=10) and fixed with two semipermanent cements (resin-based and glass ionomer-based cements) and one conventional (zinc phosphate), using conventional and modified cementation techniques on titanium abutments. The samples were stored in humid conditions for 24 hours at 37°C and subjected to thermocycling (500 cycles) and mechanical cyclic loading (7 days, 3, 6, 9 and 12 months function simulation).

View Article and Find Full Text PDF

The aim was to: (1) compare changes among primary and secondary implant stability between immediate and early loaded implants in edentulous maxilla, (2) evaluate oral health-related quality of life (OHRQoL), and (3) determine patient satisfaction with 6 implant supported fixed full-arch dentures. A prospective, randomized controlled clinical trial was conducted on 24 edentulous maxilla patients. The BLT SLActive implants in 12 patients were immediately loaded with temporary restorations while 12 patients did not receive temporary restorations.

View Article and Find Full Text PDF

Objectives: To compare the peri-implant bone healing between TiZr implants with hydrophilic SLActive and hydrophobic SLA implant surface in patients receiving anticoagulants, to assess the implant survival and success rate, as well as to evaluate whether small-diameter TiZr implants could be used in patients on OAT in order to avoid augmentation procedures.

Material And Methods: A total of 80 small-diameter tissue-level TiZr implants with SLActive and SLA surfaces were placed in 20 anticoagulated patients, following the "split-mouth" study design. Implant stability was measured up to the third postoperative month by resonance frequency measurements (RFA).

View Article and Find Full Text PDF

Background/aim: During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and temperature of irrigans on thermal changes of the local bone during drilling implant sites, and to test the influence of irrigans temperature on the temperature of surgical drill guide.

View Article and Find Full Text PDF

Aim: To evaluate by histopathological analysis the peri-implant bone inflammation degree, in certain time intervals (7, 14, 21 and 28 days), following mini-incision flapless and flap implant placement.

Material And Methods: The experiment was conducted on four domestic pigs. Nine weeks prior to implant insertion, second and third mandibular premolars were extracted.

View Article and Find Full Text PDF

Objectives: The aim of our study was to compare osseointegration and peri-implant crestal bone resorption in submerged flapless and conventional flap surgery over a 12-month follow-up.

Materials And Methods: The study used five domestic pigs. Implants were inserted 9 weeks after tooth extraction.

View Article and Find Full Text PDF

Aim: The aim of this study was comparing the effect of flapless vs. flap technique of implant placement on inflammation degree of peri-implant soft tissue, through histopathological analysis.

Method: The experiment was conducted on five domestic pigs.

View Article and Find Full Text PDF

Aim: This 1-year cohort study investigated stability and peri-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures.

Materials And Methods: Each of 30 edentulous patients received 4 mini dental implants (1.8 mm × 13 mm) in the interforaminal mandibular region.

View Article and Find Full Text PDF

Purposes: The primary aim of the study was to investigate a 1-year success rate of early-loaded bone level implants with a chemically modified sand-blasted, large grit, acid-etched surface (SLActive®, Institut Straumann AG, Basel, Switzerland) in the posterior maxilla. Secondary objectives included stability of these implants and peri-implant bone level.

Materials And Methods: Bone level® implants (Institut Straumann AG) inserted into premolar and/or molar maxillary sites were loaded after 6 weeks of healing.

View Article and Find Full Text PDF

Aim: The aim of this experimental study is to compare the effect of mini-incision flapless versus flap technique of implant placement on the amount of vascular structures and blood vessel elements in peri-implant soft tissue, using immunohistochemical analysis.

Method: The experiment was conducted on five domestic pigs. Each animal received six implants in mandible according to the split-mouth design.

View Article and Find Full Text PDF

Background/aim: Different types of dental restorations are used for the therapy of unilateral free-end saddle edentulism. Unilateral complex partial denture is one of the indications for the Kennedy class II partial edentulism. The abscence of major connector and denture plate is an advantage compared to the conventional restorations, because of better comfort and shorter period of adaptation.

View Article and Find Full Text PDF

Background/aim: Retentive force of removable partial denture (RPD) directly depends on elastic force of stretched retentive clasp arms (RCAs). During deflection RCA must have even stress distribution. Safety factor is the concept which can be applied in estimating durability and functionality of RCAs.

View Article and Find Full Text PDF

Objectives: To compare the effect of two surgical techniques, lateral condensation and bone drilling, on changes in temperature of the adjacent low-density bone during implant placement into posterior maxilla and to investigate the influence of the host factors - age, gender, region of implantation, bone density, and thickness of the cortical bone at the recipient sites.

Material And Methods: Local bone temperature was measured thermographically during implant placement into posterior maxilla following lateral bone condensing (test group) or bone drilling (controls). The main study outcomes were baseline bone temperature prior to implantation and maximum bone temperature recorded during implantation.

View Article and Find Full Text PDF

Aim: The aim of this 1-year prospective cohort study was to evaluate the outcomes and complications of immediately loaded mini dental implants used for stabilizing mandibular overdentures in edentulous patients wearing conventional complete dentures.

Materials And Methods: Thirty patients received mandibular conventional complete dentures that were subsequently retained by 4 immediately loaded mini dental implants placed in the interforaminal region. Overdenture success, implant success and biological and prosthetic complications were evaluated after the first year of service.

View Article and Find Full Text PDF

Objective: The aim of this study was to compare changes in temperature of the surrounding bone at various osteotomy depths during implant site preparation by bone condensing and by bone drilling as well as the dynamics of their change.

Study Design: In the present "in vitro" study, pig ribs with uniform thickness of cortical bone of 2 mm were used. Lateral bone-condensing (experimental group) and bone-drilling techniques (control group) were performed.

View Article and Find Full Text PDF

The design and fabrication procedures for implementing a high-density (16-microm center spacing) single-mode fiber (SMF) array are described. The specific application for this array is a parallel optical coherence tomography system for endoscopic imaging. We obtained fiber elements by etching standard single-mode SMF-28 fibers to a diameter of 14-15 microm.

View Article and Find Full Text PDF

We discuss the use of holographic photopolymer materials for use as dense wavelength division multiplexing filters in the C-band of the optical communication spectrum. An edge-illuminated hologram configuration is described that effectively extends the grating length to achieve narrow band filters operating near 1550 nm in photopolymers that are 100-200-microm thick. This configuration enables the formation of apodized and cascaded filter systems.

View Article and Find Full Text PDF