Purpose: To elucidate the characteristics of imipenem (IPM)/cilastatin (CS) as an embolic material in microvessels in vivo.
Materials And Methods: Three healthy rabbits were injected subcutaneously in 1 auricle with picibanil (OK-432) in advance to create an inflammation-induced neovascular model. Microangiography was performed using monochromatic X-rays obtained from a large synchrotron radiation facility (SuperPhoton ring-8 GeV, SPring-8).
Objective: To evaluate the relationships between hemoglobin A1c (HbA1c) levels with exocrine pancreatic function using cine-dynamic magnetic resonance cholangiopancreatography (MRCP) and the pancreatic parenchyma using fat-suppressed T1 mapping and the proton density fat fraction (PDFF).
Methods: Patients who underwent 3T-MRI and HbA1c measurement were retrospectively recruited. MRI included cine-dynamic MRCP with a spatially selective inversion-recovery (SS-IR) pulse, fat-suppressed Look-Locker T1 mapping and multiecho 3D Dixon-based PDFF mapping.
Background: Pancreatic exocrine insufficiency is one of the causes of malabsorption syndrome. In many cases of malabsorption syndrome, pancreatic exocrine insufficiency can be treated with pancreatic enzyme replacement therapy. Therefore, it is important to detect pancreatic endocrine insufficiency as early and accurately as possible.
View Article and Find Full Text PDFPurpose: To evaluate dynamic changes in apparent diffusion coefficient (ADC) values of the kidney at different time points during the cardiac cycle using electrocardiographic (ECG)-triggered diffusion-weighted MR imaging in normal subjects, and to elucidate the differences in ADC values between the right and left kidneys during a cardiac cycle.
Materials And Methods: The study was approved by our institutional review board and informed consent was obtained from subjects. Twenty healthy volunteers who underwent ECG-triggered diffusion-weighted MR imaging of the kidney were included.
Purpose: To evaluate the influence of oral ingestion on the secretory flow dynamics of physiological pancreatic juice within the main pancreatic duct in healthy subjects by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively.
Materials And Methods: Thirty-eight healthy subjects were investigated. MRCP with spatially-selective IR pulse was repeated every 15 s for 5 min to acquire a total of 20 images (cine-dynamic MRCP).
Purpose: To determine the clinical, histopathologic and imaging features of pancreatic adenocarcinomas without secondary signs on dynamic CT.
Materials And Methods: Seventy patients (mean age 70 years) with histologically proven pancreatic adenocarcinoma underwent preoperative contrast material-enhanced multiphasic multidetector CT before pancreatic resection. In each patient, clinical data including carbohydrate antigen 19-9, frequency of isoattenuating tumours, and presence of secondary signs and histopathologic findings such as tumour location, tumour stage, and microscopic infiltrative growth grade were evaluated.
Purpose: To investigate the feasibility of noncontrast-enhanced cine dynamic magnetic resonance cholangiopancreatography (MRCP) with a spatially selective inversion-recovery (IR) pulse for evaluating exocrine pancreatic function in comparison with the N-benzoyl-L-tyrosyl-p-aminobenzoic acid (BT-PABA) test as a pancreatic exocrine function test.
Materials And Methods: Twenty subjects with or without chronic pancreatitis were included. MRCP with a spatially selective IR pulse was repeated every 15 seconds for 5 minutes to acquire a total of 20 images (cine-dynamic MRCP).
Objective: To evaluate the feasibility of using magnetisation transfer (MT) MRI of the kidney at 3.0 T to assess renal function.
Methods: Forty-four patients who underwent abdominal MRI on a 3.
Purpose: The purpose of this study was to evaluate differences in the degrees of contrast enhancement effects of small hepatocellular carcinomas (HCCs) in patients with cirrhosis between helical computed tomography (CT) and magnetic resonance (MR) imaging during multiphasic contrast-enhanced dynamic imaging and to determine the diagnostic value of MR imaging especially in assessing hypovascular HCCs detected as hypoattenuating nodules on late-phase CT.
Subjects And Methods: This study included 64 small HCCs (<3 cm in diameter) in 40 patients with chronic hepatitis or cirrhosis who underwent multiphasic (arterial, portal and late phases) contrast-enhanced dynamic helical CT and MR imaging. The contrast enhancement patterns of each lesion in the arterial and late phases were evaluated by two radiologists experienced in liver MR imaging and categorized as one of five grades (1=hypoattenuated/hypointense; 2=slightly hypoattenuated/hypointense; 3=isoattenuated/isointense; 4=slightly hyperattenuated/hyperintense; 5=hyperattenuated/hyperintense), compared with the surrounding liver parenchyma.
Purpose: The aim of this study was to evaluate the frequency and magnetic resonance imaging (MRI) features of clinically benign, small (<2 cm) hyperintense hepatic lesions in the cirrhotic liver on T1-weighted MR images seen at serial MRI.
Materials And Methods: This study included 189 patients with cirrhosis, who underwent hepatic MRI more than twice with an interval of at least 12 months. The initial MR images were reviewed for the presence of small hyperintense lesions on T1-weighted images.
J Magn Reson Imaging
January 2007
Purpose: To evaluate the diagnostic capability of breath-hold, multisection fluid-attenuated inversion-recovery (FLAIR) imaging using a half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in combination with T2-weighted fast spin-echo (FSE) magnetic resonance (MR) sequences for small hepatic lesions found on CT in patients with malignancy.
Materials And Methods: This study included 48 patients with extrahepatic malignancy who underwent both CT and MR examinations. There were a total of 112 small hepatic lesions (73 cysts and 39 liver metastases, <2 cm in diameter) that showed low attenuation on enhanced CT.
Acta Crystallogr D Biol Crystallogr
September 2004
Carboxypeptidase Y (CPY) inhibitor I(C) is a naturally occurring serine carboxypeptidase inhibitor from Saccharomyces cerevisiae, the sequence of which is not homologous with any other known proteinase inhibitor and is classified as the phosphatidylethanolamine-binding protein (PEBP). I(C) has been crystallized in complex with the deglycosylated form of CPY by the hanging-drop vapour-diffusion technique with ammonium sulfate as a precipitant. The crystals of the complex belong to space group P2(1)2(1)2(1), with unit-cell parameters a = 81.
View Article and Find Full Text PDFActa Crystallogr D Biol Crystallogr
April 2004
Pokeweed lectin (PL), a lectin specific for N-acetylglucosamine-containing saccharides, stimulates peripheral lymphocytes to undergo mitosis by binding to their cell surfaces. Four types of lectins have been isolated from the roots of pokeweed (Phytolacca americana) and shown to contain homologous domains but to have different molecular sizes and biological properties. PL-D, the smallest lectin in the group, has two isolectins, PL-D1 and PL-D2.
View Article and Find Full Text PDFThe roots of pokeweed (Phytolacca americana) are known to contain the lectins designated PL-A, PL-B, PL-C, PL-D1, and PL-D2. Of these lectins, the crystal structures of two PLs, the ligand-free PL-C and the complex of PL-D2 with tri-N-acetylchitotriose, have been determined at 1.8A resolution.
View Article and Find Full Text PDFActa Crystallogr D Biol Crystallogr
July 2003
Lectin C from the roots of pokeweed (Phytolacca americana) (PL-C; 13 747 Da, 126 amino-acid residues), which consists of three chitin-binding domains, was initially crystallized in two crystal forms. One form, obtained in the presence of 30%(w/v) PEG 4000, belongs to the tetragonal system. The other, obtained in the presence of 2.
View Article and Find Full Text PDFBleomycin (Bm) in the culture broth of Streptomyces verticillus is complexed with Cu(2+) (Cu(II)). In the present study, we determined the x-ray crystal structures of the Cu(II)-bound and the metal-free types of Bm at a high resolution of 1.6 and 1.
View Article and Find Full Text PDF