Publications by authors named "Minjae Ku"

Article Synopsis
  • Widespread interest in nanoscale pillar structures for optical devices faces challenges like high equipment costs and limited scalability due to traditional manufacturing methods.
  • The study introduces a novel technique using thermally assisted nanotransfer printing to create highly uniform nanoscale pillar arrays, achieving an impressive density of 0.1 tera-pillars per square inch.
  • These nanopillars are demonstrated as effective surface-enhanced Raman scattering sensors, providing consistent performance and sensitivity at very low concentrations while maintaining durability for multiple uses.
View Article and Find Full Text PDF

Continuous detection of raised intraocular pressure (IOP) could benefit the monitoring of patients with glaucoma. Current contact lenses with embedded sensors for measuring IOP are rigid, bulky, partially block vision or are insufficiently sensitive. Here, we report the design and testing in volunteers of a soft and transparent contact lens for the quantitative monitoring of IOP in real time using a smartphone.

View Article and Find Full Text PDF

Background: Maintaining a good level of physical fitness from engaging in regular exercise is important for the treatment and prevention of metabolic syndrome (MetS). However, which components constitutive of physical fitness confer the greatest influence remains controversial. This retrospective cross-sectional study aimed to investigate the association between MetS and physical fitness components including cardiorespiratory fitness, muscle strength, flexibility, and agility and to identify which physical fitness components have the largest influence on MetS.

View Article and Find Full Text PDF

Despite various approaches to immunoassay and chromatography for monitoring cortisol concentrations, conventional methods require bulky external equipment, which limits their use as mobile health care systems. Here, we describe a human pilot trial of a soft, smart contact lens for real-time detection of the cortisol concentration in tears using a smartphone. A cortisol sensor formed using a graphene field-effect transistor can measure cortisol concentration with a detection limit of 10 pg/ml, which is low enough to detect the cortisol concentration in human tears.

View Article and Find Full Text PDF

Intraocular islet transplantation was investigated as a new procedure to treat diabetes. The development of this procedure requires close monitoring of the function of both eye and islet graft. We developed a soft, smart contact lens to monitor the intraocular pressure and applied this for noninvasive monitoring in association with the intraocular islet transplantation in diabetes.

View Article and Find Full Text PDF