Spectrochim Acta A Mol Biomol Spectrosc
May 2007
The objective of this research was to apply Fourier transform infrared spectroscopy (FTIR) and tunable infrared laser differential absorption spectroscopy (TILDAS) for measuring selected gaseous constituents in mainstream (MS) and sidestream (SS) smoke for experimental cigarettes designed to reduce MS CO using iron oxide cigarette papers. These two complimentary analytical techniques are well suited for providing per puff smoke deliveries and intra-puff evolution profiles in cigarette smoke respectively. The quad quantum cascade (QC) laser high resolution infrared spectroscopy system has the necessary temporal and spectral resolution and whole smoke analysis capabilities to provide detailed information for CO and CO(2) as they are being formed in both MS and SS smoke.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
May 2007
Acrolein and 1,3-butadiene in cigarette smoke generally are measured using two separate analytical methods, a carbonyl derivative HPLC method for acrolein and a volatile organic compound (VOC) GC/MS method for 1,3-butadiene. However, a single analytical method having improved sensitivity and real-time per puff measurement will offer more specific information for evaluating experimental carbon filtered cigarettes designed to reduce the smoke deliveries of these constituents. This paper describes an infrared technique using two lead-salt tunable diode lasers (TDLs) operating with liquid nitrogen cooling with emissions at 958.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
April 2006
Acrolein (C(3)H(4)O) molecular line parameters, including infrared (IR) absorption positions, strengths, and nitrogen broadened half-widths, must be determined since they are not included in the high resolution transmission (HITRAN) molecular absorption database of spectral lines. These parameters are required for developing a quantitative analytical method for measuring acrolein in a single puff of cigarette smoke using tunable diode laser absorption spectroscopy (TDLAS). The task is complex since acrolein has many highly overlapping infrared absorption lines in the room temperature spectrum and the cigarette smoke matrix contains thousands of compounds.
View Article and Find Full Text PDFAlthough nitrogen dioxide (NO(2)) has been previously reported to be present in cigarette smoke, the concentration estimates were derived from kinetic calculations or from measurements of aged smoke, where NO(2) was formed some time after the puff was taken. The objective of this work was to use tunable infrared laser differential absorption spectroscopy (TILDAS) equipped with a quantum cascade (QC) laser to determine if NO(2) could be detected and quantified in a fresh puff of cigarette smoke. A temporal resolution of approximately 0.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
November 2005
Endogenous metals present in tobacco from agricultural practices have been purported to generate metal carbonyls in cigarette smoke. Transition metal catalysts, such as iron oxide, have been investigated for the reduction of carbon monoxide (CO) in cigarette smoke. These studies motivated the development of an analytical method to determine if iron pentacarbonyl [Fe(CO)(5)] is present in mainstream smoke from cigarette models having cigarette paper made with iron oxide.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
December 2004
A compact, fast response, infrared spectrometer using four pulsed quantum cascade (QC) lasers has been applied to the analysis of gases in mainstream (MS) and sidestream (SS) cigarette smoke. QC lasers have many advantages over the traditional lead-salt tunable diode lasers, including near room temperature operation with thermoelectric cooling and single mode operation with improved long-term stability. The new instrument uses two 36 m, 0.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
December 2004
A technique has been developed for the determination of molecular parameters, including infrared absorption line positions, strengths, and nitrogen-broadened half-widths for 1,3-butadiene (C(4)H(6)) and propylene (C(3)H(6)). The parameters for these two molecules are required for quantitation using Tunable Diode Laser Absorption Spectroscopy (TDLAS). These molecules have populations of highly overlapping infrared absorption lines in their room temperature spectra.
View Article and Find Full Text PDFCellulose acetate (CA) filters have been investigated to determine their hydrazine (N2H4) breakthrough characteristics using a system based on tunable diode laser absorption spectroscopy (TDIAS). The breakthrough mass loading sorption curves for hydrazine were dependent on both the flow rate and the concentration. In experiments using a 4.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
September 2002
Infrared absorption lines of hydrazine are broad and typically not baseline resolved, with line strengths approximately 100 times weaker than the more widely studied compound ammonia. Hardware and software improvements have been made to a two-color infrared tunable diode laser (IR-TDL) spectrometer in order to improve the limit of detection (LOD) of hydrazine (N2H4) in the cigarette smoke matrix. The detection limit in the smoke matrix was improved from 25 parts-per-million-by-volume (ppmv) to 4.
View Article and Find Full Text PDF