The effect of mammography measurement conditions was investigated to evaluate their impact on measurement uncertainties in clinical practice. The most prominent physical X-ray beam quantities i.e.

View Article and Find Full Text PDF

Ancient DNA research in the past decade has revealed that European population structure changed dramatically in the prehistoric period (14,000-3000 years before present, YBP), reflecting the widespread introduction of Neolithic farmer and Bronze Age Steppe ancestries. However, little is known about how population structure changed from the historical period onward (3000 YBP - present). To address this, we collected whole genomes from 204 individuals from Europe and the Mediterranean, many of which are the first historical period genomes from their region (e.

View Article and Find Full Text PDF

This study reviews the performance analysis of a 137Cs irradiation system that has recently been installed in the laboratory of Uzbek National Institute of Metrology. The laboratory is responsible for calibrating calibration facilities and for calibrating most protection level radiation monitoring instruments used in medical, nuclear, industrial and academic settings in Uzbekistan. This system employs the most advanced radiation safety standards, along with 21st century source automation methods.

View Article and Find Full Text PDF

Source strength measurements are of critical importance for brachytherapy and are often performed in hospitals using well-type chambers. Quality assurance and quality control procedures should be implemented, but that may prove difficult in some hospitals due to the lack of equipment or metrological support. A study was conducted to investigate the status of the measurement equipment in Serbian hospitals and to organize an intercomparison campaign using a hospital Ir source.

View Article and Find Full Text PDF

The European Association of National Metrology Institutes (EURAMET) within its research programme European Metrology Programme for Innovation and Research (EMPIR) funded project EMPIR 19NET03 supportBSS that contributes to the establishment of a European Metrology Network (EMN) for Radiation Protection (RP). The EMN-RP was established in September 2021 with the intent to work as a meeting point for the metrology community and all stakeholders in the field of ionising radiation regulation, thus providing quality assurance for measurements in each of the exposure situations contemplated in the European Legislation. Within project EMPIR 19NET03, work package 3 aims at the preparation of a Strategic Research Agenda (SRA) by identifying the metrology needs to support the European legislation and regulation in Radiation Protection and of two Roadmaps for metrology services, one under the European Council Directive 2013/59/EURATOM and the other under the EURATOM Treaty.

View Article and Find Full Text PDF

A need for detailed testing of individual monitoring systems used in accredited service at the Vinca Institute of Nuclear Sciences was recognized following changes in individual, workplace, and environmental monitoring passive dosimetry systems acceptability criteria stated in IEC 62387:2020 and changes related to reference fields used in radiation protection defined in ISO 4037:2019. Reliability and accuracy of dosimetry data acquired by passive dosimetry systems used for individual monitoring is assured by carrying out type tests. In this manner, the effects of different radiation influence quantities are examined.

View Article and Find Full Text PDF

The paper analyses the possibility of commercial neon indicator lamp at low pressure application as a gamma radiation detector. The diode is most often used as an indicator in electrical switchers. The analysis was performed on the basis of experimental electrical breakdown time delay data as a function of relaxation time, applied voltage and gamma ray air kerma rate.

View Article and Find Full Text PDF

Doses from the exposure to outdoor radon are typically an order of magnitude smaller than those from indoor radon, causing a greater interest on investigation of the latter for radiation protection issues. As a consequence, assessment of radon priority areas (RPA) is mainly based on indoor radon measurements. Outdoor radon measurements might be needed to guarantee a complete estimation of radiological risk and may help to improve the estimation of RPA.

View Article and Find Full Text PDF

The purpose of this work is to assess accuracy and compare the performance of radionuclide calibrators (RNCs) used in nuclear medicine departments in Serbia. Testing of the RNCs included verification of measurement accuracy, as well as analysis of routinely used quality control protocols, by using the certified radioactivity standards (Co, Cs). RNCs performances were assessed with Tc through comparison of reference value for radionuclide activity and RNC measurements.

View Article and Find Full Text PDF

Open-faced charcoal canisters have been used for radon measurements for over 40 years. This method is sensitive to temperature, changing radon concentrations, humidity and other parameters, but a comprehensive study dealing with the influence quantities and measurement uncertainty was not available in literature. In this paper, all the identified influence quantities are discussed in detail, uncertainty budget is developed, good practice and bad practice examples are introduced and new recommendations are proposed to optimize the method and reduce uncertainty.

View Article and Find Full Text PDF

This paper presents experimental results of dynamic breakdown voltage and delay response as functions of gamma ray air kerma rate for xenon-filled tube at 2.7 mbar pressure. Gamma ray air kerma rate range was considered from 123 nGy h-1 up to 12.

View Article and Find Full Text PDF

In order to track "small dose effect" leading to stabilization of RADFETs with 1 μm thick oxide fabricated at Tyndall National Institute, Cork, Ireland irradiation was performed with gamma-rays in the radiation dose interval from 1 to 5 cGy, followed with room temperature annealing for the time of 28 days. Gate bias during irradiation was 0, 2.5 and 5 V.

View Article and Find Full Text PDF

The revised European Directive from 2013 regarding basic safety standard oblige EU Member States to establish a national action plan regarding the exposure to radon. At the same time, International Atomic Energy Agency started technical projects in order to assist countries to establish and implement national radon action. As a consequence, in recent years, in numerous countries national radon surveys were conducted and action plans established, which were not performed before.

View Article and Find Full Text PDF

Electronic personal dosimeters (EPDs) are increasingly being used alongside conventional thermoluminescent dosimeters to measure the dose of legal record in terms of personal dose equivalent. Therefore, it is of great importance to execute performance tests of these dosimeters in photon fields of various energies and at various angles of incidence. This testing is done in order to simulate the behavior of these dosimeters in realistic multidirectional polyenergetic ionizing radiation fields.

View Article and Find Full Text PDF

The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X- and gamma-radiation fields was tested.

View Article and Find Full Text PDF