Introduction: Silent atrial fibrillation (AF) is a common cause of cryptogenic ischemic stroke (CIS). The 24-h-Holter is insufficient to reveal an occult arrhythmic cause of stroke and the strategy to select the patients for long-term monitoring is missing.
Objectives: The aim of the study was to evaluate 7-day-Holter monitoring to identify cases with the arrhythmic cause of stroke in CIS patients in whom 24-h-Holter was free from arrhythmia, and to assess the relation between supraventricular (SV) runs in baseline Holter and the incidence of AF in a 3-year follow-up period.
Introduction: According to recent studies, silent atrial fibrillation (AF) is a common cause of cryptogenic ischemic stroke (CIS). 12-lead electrocardiogram (ECG) and 24 h Holter are not efficient to reveal an occult arrhythmic cause of stroke.
Objectives: The aim of the study was to evaluate 72 h Holter, 7 day Holter monitoring, and intermittent single-lead ECG recording in patients with CIS to identify cases with the arrhythmic cause of stroke in patients with CIS in whom 24 h ECG Holter was free from arrhythmia.