Publications by authors named "Mike Rank"

Background: In epilepsy, the ictal phase leads to cerebral hyperperfusion while hypoperfusion is present in the interictal phases. Patients with Alzheimer's disease (AD) have an increased prevalence of epileptiform discharges and a study using intracranial electrodes have shown that these are very frequent in the hippocampus. However, it is not known whether there is an association between hippocampal hyperexcitability and regional cerebral blood flow (rCBF).

View Article and Find Full Text PDF

Recently, it has been demonstrated that electromyographic (EMG) activity of auricular muscles in humans, especially the postauricular muscle (PAM), depends on the spatial location of auditory stimuli. This observation has only been shown using wet electrodes placed directly on auricular muscles. To move towards a more applied, out-of-the-laboratory setting, this study aims to investigate if similar results can be obtained using electrodes placed in custom-fitted earpieces.

View Article and Find Full Text PDF

Background: Patients with dementia with Lewy bodies (DLB) have a higher probability of seizures than in normal aging and in other types of neurodegenerative disorders. Depositions of α-synuclein, a pathological hallmark of DLB, can induce network excitability, which can escalate into seizure activity. Indicator of seizures are epileptiform discharges as observed using electroencephalography (EEG).

View Article and Find Full Text PDF

Background: In patients with Alzheimer's disease (AD) without clinical seizures, up to half have epileptiform discharges on long-term in-patient electroencephalography (EEG) recordings. Long-term in-patient monitoring is obtrusive, and expensive as compared to outpatient monitoring. No studies have so far investigated if long-term outpatient EEG monitoring is able to identify epileptiform discharges in AD.

View Article and Find Full Text PDF

The interest in sleep as a potential clinical biomarker is growing, but the standard method of sleep assessment, polysomnography, is expensive, time consuming, and requires a lot of expert assistance for both set-up and interpretation. To make sleep analysis more available both in research and in the clinic, there is a need for a reliable wearable device for sleep staging. In this case study, we test ear-electroencephalography.

View Article and Find Full Text PDF

Introduction: A device comprising two generic earpieces with embedded dry electrodes for ear-centered electroencephalography (ear-EEG) was developed. The objective was to provide ear-EEG based sleep monitoring to a wide range of the population without tailoring the device to the individual.

Methods: To validate the device ten healthy subjects were recruited for a 12-night sleep study.

View Article and Find Full Text PDF

While polysomnography (PSG) is the gold standard to quantify sleep, modern technology allows for new alternatives. PSG is obtrusive, affects the sleep it is set out to measure and requires technical assistance for mounting. A number of less obtrusive solutions based on alternative methods have been introduced, but few have been clinically validated.

View Article and Find Full Text PDF

Background: Previous studies have reported that epileptiform activity may be detectible in nearly half of patients with Alzheimer's disease (AD) on long-term electroencephalographic (EEG) recordings. However, such recordings can be uncomfortable, expensive, and difficult. Ear-EEG has shown promising results for long-term EEG monitoring, but it has not been used in patients with AD.

View Article and Find Full Text PDF

Objective: The purpose of this study was to investigate alpha power as an objective measure of effortful listening in continuous speech with scalp and ear-EEG.

Methods: Scalp and ear-EEG were recorded simultaneously during presentation of a 33-s news clip in the presence of 16-talker babble noise. Four different signal-to-noise ratios (SNRs) were used to manipulate task demand.

View Article and Find Full Text PDF

High quality sleep monitoring is done using EEG electrodes placed on the skin. This has traditionally required assistance by an expert when the equipment needed to mounted. However, this creates a limitation in how cheap and easy it can be to record sleep in the subject's own home.

View Article and Find Full Text PDF

This presentation details and evaluates a method for estimating the attended speaker during a two-person conversation by means of in-ear electro-oculography (EOG). Twenty-five hearing-impaired participants were fitted with molds equipped with EOG electrodes (in-ear EOG) and wore eye-tracking glasses while watching a video of two life-size people in a dialog solving a Diapix task. The dialogue was directionally presented and together with background noise in the frontal hemisphere at 60 dB SPL.

View Article and Find Full Text PDF

Unlabelled: Modern sleep monitoring development is shifting towards the use of unobtrusive sensors combined with algorithms for automatic sleep scoring. Many different combinations of wet and dry electrodes, ear-centered, forehead-mounted or headband-inspired designs have been proposed, alongside an ever growing variety of machine learning algorithms for automatic sleep scoring.

Objective: Among candidate positions, those in the facial area and around the ears have the benefit of being relatively hairless, and in our view deserve extra attention.

View Article and Find Full Text PDF
Article Synopsis
  • The auditory steady-state response (ASSR) is useful in pediatric audiology for estimating hearing thresholds and could be applied in mobile EEG setups; optimizing recording methods can enhance ASSR amplitude and reduce testing time.* -
  • The study examined how the ASSR responds to various repetition rates (6-198 Hz) using EEG recordings from both the scalp and ears, noting that ASSR amplitude and phase depend on repetition rate on the scalp but not in the ears.* -
  • Results indicated that high repetition rates (95-198 Hz) for chirp stimuli maintained strong ASSR signal-to-noise ratios, suggesting these settings are beneficial for both clinical and mobile applications.*
View Article and Find Full Text PDF

Background: Automatic sleep stage classification depends crucially on the selection of a good set of descriptive features. However, the selection of a feature set with an appropriate low computational cost without compromising classification performance is still a challenge. This study attempts to represent sleep EEG patterns using a minimum number of features, without significant performance loss.

View Article and Find Full Text PDF

Purpose: To assess automatic sleep staging of three ear-EEG setups with different electrode configurations and compare performance with concurrent polysomnography and wrist-worn actigraphy recordings.

Methods: Automatic sleep staging was performed for single-ear, single-ear with ipsilateral mastoid, and cross-ear electrode configurations, and for actigraphy data. The polysomnography data were manually scored and used as the gold standard.

View Article and Find Full Text PDF

Muscle activation during sleep is an important biomarker in the diagnosis of several sleep disorders and neurodegenerative diseases. Muscle activity is typically assessed manually based on the EMG channels from polysomnography recordings. Ear-EEG provides a mobile and comfortable alternative for sleep assessment.

View Article and Find Full Text PDF

Sleep spindles are brief oscillatory events observed in EEG measurements during sleep, related to both sleep staging and basic neuroscience. The objective of this study was to investigate to which extent sleep spindles are observable from ear-EEG. The analysis was based on single-night recordings from 12 subjects, wearing both a polysomnography setup and two light-weight mobile EEG devices (ear-EEG).

View Article and Find Full Text PDF

People with hearing impairment typically have difficulties following conversations in multi-talker situations. Previous studies have shown that utilizing eye gaze to steer audio through beamformers could be a solution for those situations. Recent studies have shown that in-ear electrodes that capture electrooculography in the ear (EarEOG) can estimate the eye-gaze relative to the head, when the head was fixed.

View Article and Find Full Text PDF

Sleep is a key phenomenon to both understanding, diagnosing and treatment of many illnesses, as well as for studying health and well being in general. Today, the only widely accepted method for clinically monitoring sleep is the polysomnography (PSG), which is, however, both expensive to perform and influences the sleep. This has led to investigations into light weight electroencephalography (EEG) alternatives.

View Article and Find Full Text PDF

Objective: Ear-EEG is a recording method in which EEG signals are acquired from electrodes placed on an earpiece inserted into the ear. Thereby, ear-EEG provides a noninvasive and discreet way of recording EEG, and has the potential to be used for long-term brain monitoring in real-life environments. Whereas previously reported ear-EEG recordings have been performed with wet electrodes, the objective of this study was to develop and evaluate dry-contact electrode ear-EEG.

View Article and Find Full Text PDF

A method for brain monitoring based on measuring the electroencephalogram (EEG) from electrodes placed in-the-ear (ear-EEG) was recently proposed. The objective of this study is to further characterize the ear-EEG and perform a rigorous comparison against conventional on-scalp EEG. This is achieved for both auditory and visual evoked responses, over steady-state and transient paradigms, and across a population of subjects.

View Article and Find Full Text PDF

The integration of brain monitoring based on electroencephalography (EEG) into everyday life has been hindered by the limited portability and long setup time of current wearable systems as well as by the invasiveness of implanted systems (e.g. intracranial EEG).

View Article and Find Full Text PDF