Publications by authors named "Mikael Gunnarsson"

Objective: The aim of this study was to assess the risk of radiation-induced cancer development in patients that have undergone an infrarenal EVAR, stratifying the relative contributions of the procedure and the preoperative and postoperative CTAs.

Methods And Materials: The organ-specific absorbed radiation doses from CTA and the EVAR procedure were estimated from the radiation exposures of 95 and 45 male patients, respectively. Lifetime attributable risk (LAR) cancer predictions were calculated for 14 different organs.

View Article and Find Full Text PDF

The objective was to design a thin, flex card based personal dosemeter with low angular and energy dependence. It is based on silicon diodes that can measure the personal dose equivalent. Anisotropic conducting adhesive was used to connect the Si sensor to the flex card.

View Article and Find Full Text PDF

The objective of this study was to investigate the characteristics of a solid-state detector commonly available at hospitals for parallel use as a real-time personal radiation monitor following radiation emergency situations. A solid-state detector probe with an inherent filtration (R100, RTI Electronics AB, Mölndal, Sweden) was chosen for evaluation. The energy dependence and the linearity in signal response with kerma in air were examined, and the detector was exposed to both X-ray beams using a conventional X-ray unit with effective photon energies ranging between 28.

View Article and Find Full Text PDF

Background: Mounting collective radiation doses from computed tomography (CT) implies an increased risk of radiation-induced cancer in exposed populations, especially in the young.

Purpose: To evaluate radiation dose and image quality at 80-kVp CT to diagnose acute pulmonary embolism (PE) compared with a previous study at 100 and 120 kVp with all other scanning parameters unchanged.

Material And Methods: A custom-made chest phantom with a 12 mg I/mL-syringe was scanned at 80/100/120 kVp to evaluate relative changes in computed tomographic dose index (CTDI(vol)), attenuation, image noise, and contrast-to-noise ratio (CNR).

View Article and Find Full Text PDF

Study Design: Retrospective study.

Objectives: To optimize the radiation doses and image quality for the cone-beam O-arm surgical imaging system in spinal surgery.

Summary Of Background: Neurovascular compromise has been reported after screw misplacement during thoracic pedicle screw insertion.

View Article and Find Full Text PDF

Background: Today, practically all computed tomography (CT) systems are delivered with automatic exposure control (AEC) systems operating with tube current modulation in three dimensions. Each of these systems has different specifications and operates somewhat differently.

Purpose: To evaluate AEC systems from four different CT scanner manufacturers: General Electric (GE), Philips, Siemens, and Toshiba, considering their potential for reducing radiation exposure to the patient while maintaining adequate image quality.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the effect of different choices of adaptation strengths on image quality and radiation exposure to the patient with Siemens automatic exposure control system called CARE Dose 4D. An anthropomorphic chest phantom was used to simulate the patient and computed tomography scans were performed with a Siemens SOMATOM Sensation 16 and 64. Owing to adaptation strengths, a considerable reduction (26.

View Article and Find Full Text PDF

The collective effective radiation dose to the population is increasing due to a higher use of computerised tomography. SharpView AB, Linköping, Sweden, has developed an adaptive non-linear post-processing image filtration that may enable the use of lower radiation doses. The present study assessed if a lower dose with image filtration had the same image quality as a higher dose without the filter applied.

View Article and Find Full Text PDF

The purpose of this study was to verify and validate a noise simulation tool called Dose Tutor (VAMP GmbH) in terms of level and texture of the simulated noise. By adding artificial noise to measured computed tomography (CT) raw data, a scan acquired with a lower dose (mAs) than the actual one can be simulated. A homogeneous polyethylene phantom and an anthropomorphic chest phantom were scanned for different mAs levels, tube voltages, slice thicknesses and reconstruction kernels.

View Article and Find Full Text PDF

The study aims were to estimate the radiation dose in patients examined with low dose spine CT and to compare it with that received by patients undergoing standard CT for trauma of the same region, as well as to evaluate the impact of dose reduction on image quality. Radiation doses in 113 consecutive low dose spine CTs were compared with those in 127 CTs for trauma. The inter- and intraobserver agreement in measurements of pedicular width, and vertebral rotation, measurements of signal-to-noise ratio and assessment of hardware status were the indicators in the evaluation of image quality.

View Article and Find Full Text PDF

The (14)C-glycocholic acid and (14)C-xylose breath tests are clinically used for the diagnosis of intestinal diseases, such as bacterial overgrowth in the small intestine. The two tests have in earlier studies been thoroughly evaluated regarding their clinical value, but due to the long physical half-life of (14)C and the limited biokinetic and dosimetric data, which are available for humans, several hospitals have been restrictive in their use. The aim of this study was to investigate the long-term biokinetics and dosimetry of the two (14)C compounds in patients and volunteers, using the highly sensitive accelerator mass spectrometry (AMS) technique.

View Article and Find Full Text PDF

The glycerol tri[1-14C]olein test for fat malabsorption was carried out in two male volunteers and measurements of the loss of 14C in expired air, urine and faeces and the retention of 14C in biopsy samples of abdominal fat were made using accelerator mass spectrometry. Exhalation accounted for 73% and 55% of the administered activity and could be described by three-component exponential functions with halftimes of about 1h, 2 days and 150 days, respectively. Urinary excretion accounted for 24% of the administered activity, almost all during the first 24h after administration; about 2% was excreted in the faeces in 48h.

View Article and Find Full Text PDF