Background: Several factors may decrease the accuracy of quantitative PET myocardial perfusion imaging (MPI). It is therefore essential to ensure that myocardial blood flow (MBF) values are reproducible and accurate, and to design systematic protocols to achieve this. Until now, no systematic phantom protocols have been available to assess the technical factors affecting measurement accuracy and reproducibility in MPI.
View Article and Find Full Text PDFBackground: New Block-Sequential-Regularized-Expectation-Maximization (BSREM) image reconstruction technique has been introduced for clinical use mainly for oncologic use. Accurate and quantitative image reconstruction is essential in myocardial perfusion imaging with positron emission tomography (PET) as it utilizes absolute quantitation of myocardial blood flow (MBF). The aim of the study was to evaluate BSREM reconstruction for quantitation in patients with suspected coronary artery disease (CAD).
View Article and Find Full Text PDFBackground: Attenuation correction is crucial in quantitative positron emission tomography-magnetic resonance (PET-MRI) imaging. We evaluated three methods to improve the segmentation and modelling of the attenuation coefficients in the nasal sinus region. Two methods (cuboid and template method) included a MRI-CT conversion model for assigning the attenuation coefficients in the nasal sinus region, whereas one used fixed attenuation coefficient assignment (bulk method).
View Article and Find Full Text PDFBackground: Dual-gating reduces respiratory and cardiac motion effects but increases noise. With motion correction, motion is minimized and image quality preserved. We applied motion correction to create end-diastolic respiratory motion corrected images from dual-gated images.
View Article and Find Full Text PDFUnlabelled: In Myocardial Perfusion Imaging (MPI) with Positron Emission Tomography/Computed Tomography (PET/CT) systems, accurate quantification is essential. We assessed flow quantification accuracy over various injected activities using a flow phantom.
Methods: The study was performed on the digital 4-ring Discovery MI (DMI-20) and analog Discovery 690 (D690) PET/CT systems, using 325-1257 MBq of [O]HO.
Background: We investigated the image quality of C, Ga, F and Zr, which have different positron fractions, physical half-lifes and positron ranges. Three small animal positron emission tomography/computed tomography (PET/CT) systems were used in the evaluation, including the Siemens Inveon, RAYCAN X5 and Molecubes β-cube. The evaluation was performed on a single scanner level using the national electrical manufacturers association (NEMA) image quality phantom and analysis protocol.
View Article and Find Full Text PDFMagnetic resonance imaging-only radiotherapy treatment planning (MRI-only RTP) and positron emission tomography (PET)-MRI imaging require generation of synthetic computed tomography (sCT) images from MRI images. In this study, initial dosimetric evaluation was performed for a previously developed MRI-based attenuation correction (MRAC) method for use in MRI-only RTP of the brain. MRAC-based sCT images were retrospectively generated from Dixon MR images of 20 patients who had previously received external beam radiation therapy (EBRT).
View Article and Find Full Text PDFIn contemporary interventional cardiology, for typical elderly patients, the most severe radiation-related harm to patients can be considered to come from skin exposures. In this paper, maximum local skin doses in cardiological procedures are explored with Gafchromic film dosimetry. Film and reader calibrations and reading were performed at the Secondary Standards Dosimetry Laboratory of the Radiation and Nuclear Safety Authority (STUK), and data were gathered from seven hospitals in Finland.
View Article and Find Full Text PDFDual cardiac and respiratory gating is a well-known technique for motion compensation in nuclear medicine imaging. In this study, we present a new data fusion framework for dual cardiac and respiratory gating based on multidimensional microelectromechanical (MEMS) motion sensors. Our approach aims at robust estimation of the chest vibrations, that is, high-frequency precordial vibrations and low-frequency respiratory movements for prospective gating in positron emission tomography (PET), computed tomography (CT), and radiotherapy.
View Article and Find Full Text PDFBackground: Assessment of myocardial viability is often needed in patients with chest pain and reduced ejection fraction. We evaluated the performance of reduced resting MBF, perfusable tissue fraction (PTF), and perfusable tissue index (PTI) in the assessment of myocardial viability in a pig model of myocardial infarction (MI).
Methods And Results: Pigs underwent resting [O]water PET perfusion study 12 weeks after surgical (n = 16) or 2 weeks after catheter-based (n = 4) occlusion of the proximal left anterior descending coronary artery.
The amount of interventional procedures such as percutaneous coronary intervention (PCI), transcatheter aortic valve implantation (TAVI), pacemaker implantation (PI) and ablations has increased within the previous decade. Simultaneously, novel fluoroscopy mainframes enable lower radiation doses for patients and operators. Therefore, there is a need to update the existing diagnostic reference levels (DRLs) and propose new ones for common or recently introduced procedures.
View Article and Find Full Text PDFWe evaluated the relationships between regional myocardial strain measured by speckle tracking echocardiography and viability, fibrosis, hypertrophy and oxygen consumption in the infarcted or remote myocardium in a pig model of chronic myocardial infarction (MI). Thirteen farm pigs with surgical occlusion of the left anterior descending coronary artery and five sham-operated pigs were studied 3 mo post-MI. Computed tomography revealed significant left ventricle remodeling.
View Article and Find Full Text PDFPositron emission tomography (PET) is a non-invasive imaging technique which may be considered as the state of art for the examination of cardiac inflammation due to atherosclerosis. A fundamental limitation of PET is that cardiac and respiratory motions reduce the quality of the achieved images. Current approaches for motion compensation involve gating the PET data based on the timing of quiescent periods of cardiac and respiratory cycles.
View Article and Find Full Text PDFGyrocardiography (GCG) is a new non-invasive technique for assessing heart motions by using a sensor of angular motion - gyroscope - attached to the skin of the chest. In this study, we conducted simultaneous recordings of electrocardiography (ECG), GCG, and echocardiography in a group of subjects consisting of nine healthy volunteer men. Annotation of underlying fiducial points in GCG is presented and compared to opening and closing points of heart valves measured by a pulse wave Doppler.
View Article and Find Full Text PDFUnlabelled: The aim was to evaluate effects of voltage, noise input (NI) and iterative reconstruction (IR) on radiation dose and image quality in order to establish a contrast enhanced low-dose protocol for assessment of acute appendicitis. An anthropomorphic abdominal phantom mimicking contrast enhanced abdomen was scanned with 80, 100 and 120 kV, standard and strong IR and 11 NIs (66 protocols). A total of 14 test tubes of increasing iodine dilutions and one tube with an appendicolith were evaluated within the phantom.
View Article and Find Full Text PDFIn PET, corrections for photon scatter and attenuation are essential for visual and quantitative consistency. MR attenuation correction (MRAC) is generally conducted by image segmentation and assignment of discrete attenuation coefficients, which offer limited accuracy compared with CT attenuation correction. Potential inaccuracies in MRAC may affect scatter correction, because the attenuation image (μ-map) is used in single scatter simulation (SSS) to calculate the scatter estimate.
View Article and Find Full Text PDFThe pumping action of the heart is performed by contraction of the myocardium fibers. We present a non-invasive technique named gyrocardiography (GCG) that comprises a sensor of angular motion, gyroscope, configured to obtain three-dimensional angular velocity signals. A tri-axial micro electromechanical (MEMS) gyroscope sensor was attached to the surface of the chest to obtain gyrocardiogram.
View Article and Find Full Text PDFBackground: We evaluated echocardiographic area-length methods to measure left ventricle (LV) volumes and ejection fraction (EF) in parasternal short axis views in comparison with cardiac computed tomography (CT) in pigs with chronic myocardial infarction (MI).
Methods: Male farm pigs with surgical occlusion of the left anterior descending coronary artery (n = 9) or sham operation (n = 5) had transthoracic echocardiography and cardiac-CT 3 months after surgery. We measured length of the LV in parasternal long axis view, and both systolic and diastolic LV areas in parasternal short axis views at the level of mitral valve, papillary muscles and apex.
Heart rate monitoring helps in assessing the functionality and condition of the cardiovascular system. We present a new real-time applicable approach for estimating beat-to-beat time intervals and heart rate in seismocardiograms acquired from a tri-axial microelectromechanical accelerometer. Seismocardiography (SCG) is a non-invasive method for heart monitoring which measures the mechanical activity of the heart.
View Article and Find Full Text PDFUnlabelled: A spatial bias in brain PET/MR exists compared with PET/CT, because of MR-based attenuation correction. We performed an evaluation among 4 institutions, 3 PET/MR systems, and 4 PET/CT systems using an anthropomorphic brain phantom, hypothesizing that the spatial bias would be minimized with CT-based attenuation correction (CTAC).
Methods: The evaluation protocol was similar to the quantification of changes in neurologic PET studies.