Publications by authors named "Miguel Palacios"

. This study aimed to evaluate two real-time target tracking approaches for magnetic resonance imaging (MRI) guided radiotherapy (MRgRT) based on foundation artificial intelligence models..

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the knowledge and experiences of family members and medical staff regarding oral health care for older adults with cognitive impairment and Alzheimer's disease.
  • Through interviews with 30 participants, the researchers gathered insights that revealed a general lack of knowledge and understanding about oral hygiene practices and their importance among both family members and formal caregivers.
  • Findings indicated a need for better education and resources to help caregivers provide adequate oral health care, highlighting its critical role in enhancing the quality of life for older adults.
View Article and Find Full Text PDF

Introduction: Use of stereotactic ablative radiotherapy (SABR) for central lung tumors can result in up to a 35% incidence of late pulmonary toxicity. We evaluated an automated scoring method to quantify post-SABR bronchial changes by using artificial intelligence (AI)-based airway segmentation.

Materials And Methods: Central lung SABR patients treated at Amsterdam UMC (AUMC, internal reference dataset) and Peter MacCallum Cancer Centre (PMCC, external validation dataset) were identified.

View Article and Find Full Text PDF
Article Synopsis
  • This study investigates the effectiveness and safety of MR-guided stereotactic body radiotherapy (MRgSBRT) for treating adrenal gland metastases, highlighting its clinical outcomes and toxicity levels.
  • A total of 255 patients with 269 adrenal metastases were analyzed, showing high local progression-free survival rates (94% at 1 year) and minimal severe toxicity (only 0.8% grade 3+ events).
  • The findings suggest that frequent dose adaptations are crucial for optimal outcomes, with improved results associated with higher radiation doses and single-fraction treatments, establishing benchmarks for future research.
View Article and Find Full Text PDF

Background And Purpose: The optimal stereotactic ablative radiotherapy (SABR) doses for adrenal tumors are unknown. Some trials have specified that organ at risk (OAR) dose constraints should take priority over target coverage. We performed a retrospective review of the outcomes of MR-guided adrenal SABR (MRgRT) delivered with OAR sparing.

View Article and Find Full Text PDF

Purpose: Magnetic resonance imaging (MR)-guided radiotherapy permits continuous intrafraction visualization and use of automatic triggered beam delivery, with use of smaller planning target volumes (PTV). We report on long-term clinical outcomes following MR-guided single fraction (SF) lung SABR on a 0.35 T linac.

View Article and Find Full Text PDF

Purpose: Gross tumor volume (GTV) changes during stereotactic ablative radiotherapy (SABR) for adrenal tumors are not well characterized. We studied treatment-induced GTV changes during, and after, 5-fraction MR-guided SABR on a 0.35 T unit.

View Article and Find Full Text PDF

Background: Partial breast irradiation (PBI) is standard of care in low-risk breast cancer patients after breast-conserving surgery (BCS). Pre-operative PBI can result in tumor downstaging and more precise target definition possibly resulting in less treatment-related toxicity. This study aims to assess the pathologic complete response (pCR) rate one year after MR-guided single-dose pre-operative PBI in low-risk breast cancer patients.

View Article and Find Full Text PDF
Article Synopsis
  • Intra-fraction motion management is crucial for the accuracy of Stereotactic Ablative Radiotherapy (SABR), and this study evaluated the effectiveness of automatic tumor segmentation in MR-guided radiotherapy compared to manual delineation.
  • Twenty patients with either thoracic or abdominal tumors were analyzed using a combination of experienced observers' manual delineations and four different algorithms for automatic tumor contouring, assessing accuracy through various geometrical analysis metrics.
  • Results showed that the automatic segmentation algorithms achieved excellent agreement with manual contours, demonstrating high reliability and accuracy, thereby supporting the use of DIR-based auto-contouring in MRgRT for precise treatment delivery.
View Article and Find Full Text PDF

Background: Stereotactic body radiation therapy (SBRT) of central lung tumors with photon or proton therapy has a risk of increased toxicity. Treatment planning studies comparing accumulated doses for state-of-the-art treatment techniques, such as MR-guided radiotherapy (MRgRT) and intensity modulated proton therapy (IMPT), are currently lacking.

Purpose: We conducted a comparison of accumulated doses for MRgRT, robustly optimized non-adaptive IMPT, and online adaptive IMPT for central lung tumors.

View Article and Find Full Text PDF

Objective: The goal of this consensus expert opinion was to define quality assurance (QA) tests for online magnetic resonance image (MRI) guided radiotherapy (oMRgRT) systems and to define the important medical physics aspects for installation and commissioning of an oMRgRT system.

Materials And Methods: Ten medical physicists and two radiation oncologists experienced in oMRgRT participated in the survey. In the first round of the consensus expert opinion, ideas on QA and commissioning were collected.

View Article and Find Full Text PDF

The patient's lifestyle was undoubtedly to blame for the appearance of her skin. The loss of her beloved pet may have been a tipping point.

View Article and Find Full Text PDF

Background And Purpose: Magnetic resonance-guided radiotherapy (MRgRT) with real-time intra-fraction tumor motion monitoring allows for high precision Stereotactic Ablative Radiotherapy (SABR). This study aimed to investigate the clinical feasibility, patient satisfaction and delivery accuracy of single-fraction MR-guided SABR in a single day (one-stop-shop, OSS).

Methods And Materials: Ten patients with small lung tumors eligible for single fraction treatments were included.

View Article and Find Full Text PDF

Magnetic resonance-guided radiotherapy with daily plan adaptation for intermediate- and high-risk prostate cancer is time and labor intensive. Fifty adapted plans with 3 mm planning target volume (PTV)-margin were compared with non-adapted plans using 3 or 5 mm margins. Adequate (V95% ≥ 95%) prostate coverage was achieved in 49 fractions with 5 mm PTV without plan adaptation, however, coverage of the seminal vesicles (SV) was insufficient in 15 of 50 fractions.

View Article and Find Full Text PDF

We studied treatment patterns for adrenal metastases using surgery or SABR at a single institution during a 10-year period. The number of patients undergoing SABR doubled since 2016, without a change in numbers undergoing surgery. Both treatments resulted in low rates of acute toxicity and similar survivals.

View Article and Find Full Text PDF

Stereotactic ablative radiotherapy (SABR) planning for adrenal metastases aims to minimize doses to the adjacent kidney. Renal dose constraints for SABR delivery are not well defined. In 20 patients who underwent MR-guided breath-hold SABR in five daily fractions of 8-10 Gy, ipsilateral renal volumes receiving ≥20 Gy best correlated with loss of renal volumes, with median renal volume reduction being 6% (range: 3%-11%, 10th-90th percentiles).

View Article and Find Full Text PDF

Background And Purpose: Adaptive MR-guided radiotherapy (MRgRT) is an innovative approach for delivering stereotactic body radiotherapy (SBRT) in prostate cancer (PC). Despite the increased clinical use of SBRT for PC, there is limited data on the relation between the actual delivered dose and toxicity. We aimed to identify dose parameters based on the total accumulated delivered bladder dose (DOSE).

View Article and Find Full Text PDF

Background And Purpose: Single-fraction stereotactic ablative radiotherapy (SABR) is an effective treatment for early-stage lung cancer, but concerns remain about the accurate delivery of SABR in a single session. We evaluated the delivery of single-fraction lung SABR using magnetic resonance (MR)-guidance.

Materials And Methods: An MR-simulation was performed in 17 patients, seven of whom were found to be unsuitable, largely due to unreliable tracking of small tumors.

View Article and Find Full Text PDF

Novel magnetic-resonance-guided radiotherapy (MRgRT) permits real-time soft-tissue visualization, respiratory-gated delivery with minimal safety margins, and time-consuming daily plan re-optimisation. We report on early clinical outcomes of MRgRT and routine plan re-optimization for large primary renal cell cancer (RCC). Thirty-six patients were treated with MRgRT in 40 Gy/5 fractions.

View Article and Find Full Text PDF

Delivery of breath-hold MR-guided SABR is time-consuming, and the use of real-time tumor-tracking in a sagittal plane may fail to detect out-of-plane displacements of organs-at-risk. Analysis of daily MR-scans performed pre- and post-SABR revealed frequent decreases in stomach volumes, and in the planned stomach doses.

View Article and Find Full Text PDF

In the evolving field of adaptive MR guided radiotherapy, the need for dedicated procedures for acceptance and quality assurance is increasing. Research has been devoted to MR compatible dosimeters and phantoms, but to date no end-to-end test has been presented that covers an MRgRT workflow. Such an end-to-end test should comprise each step of the workflow and include all associated uncertainties.

View Article and Find Full Text PDF

Purpose: Magnetic resonance (MR)-guided SABR was performed for patients with lung tumors in whom treatment delivery was challenging owing to tumor location, motion, or pulmonary comorbidity. Because stereotactic MR-guided adaptive radiation therapy (SMART) is a novel approach, we studied clinical outcomes in these high-risk lung tumors.

Methods And Materials: Fifty consecutive patients (54 lung tumors) underwent SMART between 2016 and 2018 for either a primary lung cancer (29 patients) or for lung metastases (21 patients).

View Article and Find Full Text PDF

Background And Purpose: We studied the benefits of using stereotactic MR-guided adaptive radiation therapy (SMART) for delivery of SABR in peripherally located lung tumors.

Methods And Materials: Twenty-three patients (25 peripheral lung tumors) underwent SMART in 3-8 fractions on an MR Linac or Cobalt-60 system. Before each fraction, a breath-hold MR scan was acquired, followed by on-table plan adaptation based on the anatomy-of-the-day.

View Article and Find Full Text PDF

Background And Purpose: This work evaluates the accuracy of deformable dose accumulation for organs at risk (OAR) in MR-guided prostate SBRT using an anthropomorphic deformable phantom.

Materials And Methods: Six MR-guided prostate SBRT treatment courses were simulated using volumetric OAR (bladder and rectum) information derived from actual patient data. Deformed OAR contours, geometrical landmarks and GafChromic EBT3 film strips (1.

View Article and Find Full Text PDF

This publication is a resume of the GOCO Congress (Montpellier 2017). A part of this congress was about the use of MRI in clinical practice, focused on the oncology field. The role of this tool was described in diagnosis, staging of tumors, evaluation of treatment response and the future use in prognostic and investigation (radiomics).

View Article and Find Full Text PDF