Background: The 3M™ Petrifilm™ Rapid Aerobic Count (RAC) Plate is a sample-ready culture medium system designed to facilitate colony enumeration in 24 h (48 h for dry powders) for selected food and environmental surfaces.
Objective: The objective of this study is to evaluate the 3M Petrifilm RAC Plate in a matrix extension study for the enumeration of aerobic bacteria on stainless steel, sealed concrete, and rubber surfaces.
Method: The 3M Petrifilm RAC Plate was compared to the U.
Background: The 3M™ Petrifilm™ Rapid Yeast and Mold Count (RYM) Plate contains nutrients supplemented with antibiotics, a cold-water-soluble gelling agent, and an indicator system that facilitates yeast and mold enumeration in 48-60 h.
Objective: The objective of this study is to evaluate the 3M Petrifilm RYM Plate in a matrix extension study for the enumeration of yeast and mold on stainless steel, sealed concrete, and rubber surfaces.
Methods: The 3M Petrifilm RYM Plate was compared to the U.
Background: The 3M™ Molecular Detection Assay 2-Salmonella method is based on real-time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Salmonella in enriched products. The 3M Molecular Detection Assay 2-Salmonella was approved as AOAC INTERNATIONAL (AOAC) Performance Tested MethodSM (PTM) Certificate No. 091501 and as AOAC Official Method of AnalysisSM2016.
View Article and Find Full Text PDFBackground: The 3M™ Molecular Detection Assay 2-STEC Gene Screen (stx and eae) method is based on gene amplification by the use of real time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) and intimin gene (eae) from Shiga toxin-producing Escherichia coli (STEC) in enriched products. The 3M Molecular Detection Assay 2-STEC Gene Screen (stx and eae) was approved as AOAC Performance Tested MethodSM Certificate No. 071902.
View Article and Find Full Text PDFBackground: The 3M™ Molecular Detection Assay 2-STEC Gene Screen (stx) method is based on gene amplification by the use of real-time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) from Shiga toxin-producing Escherichia coli (STEC) in enriched products. The 3M Molecular Detection Assay 2-STEC Gene Screen (stx) was approved as AOAC Performance Tested MethodSM Certificate No. 071903.
View Article and Find Full Text PDFBackground: The 3M™ Molecular Detection Assay 2 - STEC Gene Screen (stx and eae) method is based on gene amplification by the use of real-time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) and intimin gene (eae) from Shiga toxin-producing enterohemorrhagic Escherichia coli (STEC) in enriched foods.
Objective: The 3M Molecular Detection Assay 2 - STEC Gene Screen (stx and eae) method was evaluated as a Level 2 method modification to add new matrixes to the certified claim: 25 g fresh raw ground beef (approximately 75% lean), 375 g fresh raw ground pork (approximately 70% lean), 375 g fresh raw poultry parts, and 25 g sprouts.
Methods: Matrix studies were conducted to assess the method's performance compared to the U.
Background: The 3M™ Molecular Detection Assay 2 - STEC Gene Screen (stx) method is based on gene amplification by the use of real-time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) from Shiga toxin-producing enterohemorrhagic Escherichia coli (STEC) in enriched foods.
Objective: The 3M Molecular Detection Assay 2 - STEC Gene Screen (stx) method was evaluated as a Level 2 method modification to add new matrixes to the certified claim: 25 g fresh raw ground beef (approximately 75% lean), 375 g raw beef trim (approximately 75% lean), 375 g fresh raw ground pork (approximately 70% lean), 375 g fresh raw poultry parts, and 25 g sprouts.
Methods: Matrix studies were conducted to assess the method's performance compared to the US Department of Agriculture Food Safety and Inspection Service Microbiology Laboratory Guidebook, 5C.
Background: The 3M™ Molecular Detection Assay 2 - STEC Gene Screen (stx) method is based on gene amplification by the use of real time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) from Shiga toxin-producing Escherichia coli (STEC) in enriched foods. The stx assay does not differentiate between stx1 and stx2 but detects the presence of stx1 and/or stx2.
Objective: The 3M Molecular Detection Assay 2 - STEC Gene Screen (stx) method was evaluated for AOAC® Performance Tested MethodsSM certification.
Background: The 3M™ Environmental Scrub Sampler with 10 mL Wide Spectrum Neutralizer is a nonspecific sampling device intended for use for environmental monitoring surface sampling.
Objective: The aim was to evaluate 3M Wide Spectrum Neutralizer using the 3M Environmental Scrub Sampler for AOAC® Performance Tested MethodsSM (PTM) certification.
Methods: Matrix studies, inclusivity/exclusivity, product consistency/stability, neutralization, and robustness testing were conducted for Salmonella and Listeria species.