In spot-scanning proton therapy, highly precise beam control is required in the treatment nozzle such that the proton beam does not spread out during transportation by restraining the divergence of the beam angle and spot size, simultaneously. In order to evaluate the beam-broadening behaviour induced by passing through the various nozzle components, we have developed a new method to calculate the angular divergence profile of a proton beam in the nozzle. The angular divergence of the proton beam for each nozzle component is calculated by the Monte Carlo simulation code, Geant4, assuming that the initial beam has no divergence.
View Article and Find Full Text PDFResults of this study demonstrated that electroless nickel-phosphorus (NiP) plated metal substrate is an excellent material for producing large aspherical neutron-focusing supermirrors. A large plano-elliptical neutron-focusing supermirror comprising two metallic segments was fabricated using single-point diamond cutting, precision polishing and supermirror coating. The average surface roughness of the metallic substrates was approximately 0.
View Article and Find Full Text PDFAn increasing number of neutron focusing mirrors is being adopted in neutron scattering experiments in order to provide high fluxes at sample positions, reduce measurement time, and/or increase statistical reliability. To realize a small focusing spot and high beam intensity, mirrors with both high form accuracy and low surface roughness are required. To achieve this, we propose a new figure correction technique to fabricate a two-dimensional neutron focusing mirror made with electroless nickel-phosphorus (NiP) by effectively combining ultraprecision shaper cutting and fine polishing.
View Article and Find Full Text PDFWe propose an ellipsoidal neutron focusing mirror using a metal substrate made with electroless nickel-phosphorus (NiP) plated material for the first time. Electroless NiP has great advantages for realizing an ellipsoidal neutron mirror because of its amorphous structure, good machinability and relatively large critical angle of total reflection for neutrons. We manufactured the mirror by combining ultrahigh precision cutting and fine polishing to generate high form accuracy and low surface roughness.
View Article and Find Full Text PDFHere, we illustrated that the morphological structures of ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) variants and Parkinson's disease (PD) exhibit good pathological correlation by a small-angle neutron scattering (SANS). UCH-L1 is a neuro-specific multiple functional enzyme, deubiquitinating, ubiquityl ligase, and also involved in stabilization of mono-ubiquitin. To examine the relationship between multiple functions of UCH-L1 and the configuration of its variants [wild-type, I93M (linked to familial Parkinson's disease), and S18Y (linked to reduced risk of Parkinson's disease)], in this report, we proposed that these were all self-assembled dimers by an application of a rotating ellipsoidal model; the configurations of these dimers were quite different.
View Article and Find Full Text PDFAqueous gel-like solutions of N-acyl-L-aspartic acids (C(n)Asp, n=14, 16, 18) and N-dodecanoyl-beta-alanine (C(12)Ala) were prepared at pH 5-6 at room temperature. Structures of supramolecular assemblies in the solutions were investigated by atomic force microscopy (AFM), small-angle neutron scattering (SANS), and small-angle X-ray scattering (SAXS). The cross-sectional radii, 22-30 Å, of helical, fibrous assemblies were obtained from analysis of SANS for 1% gel-like C(n)Asp solutions.
View Article and Find Full Text PDF