The phase ratio of a chromatographic system is an important measurement that has long been estimated or calculated, but rarely directly measured. This study utilized a nanoflow liquid chromatography instrument to more accurately measure the phase ratio for a lauryl acrylate porous polymer monolith. Direct measurement of the phase ratio, and its dependence on temperature, allows for a better understanding of the thermodynamics of retention of small analytes.
View Article and Find Full Text PDFThe development of organic porous polymer monoliths represents an alternative approach to stationary phase design. The use of these materials has helped to rekindle interest in capillary electrochromatography. Although a large number of investigations have explored different monolith recipes, polymerization conditions, and application challenges, few investigations have addressed the fundamentals of this separation mode with this type of material.
View Article and Find Full Text PDFThe peak parking method was used to determine the obstruction factor of lauryl acrylate porous polymer monoliths. Polymers were prepared in situ in fused-silica capillaries using thermally initiated polymerization. These columns have been used for CEC of neutral analytes.
View Article and Find Full Text PDFA variety of porous polymer monoliths (PPMs) have been synthesized using the 'conduct-as-cast' format. The resulting polymers have been evaluated for use as separation media in capillary electrochromatography (CEC). The results have shown that substituting a small percentage of the standard polymer formulation with a more hydrophobic monomer produced columns with expected increases in retention for a neutral analyte series.
View Article and Find Full Text PDFMicellar electrokinetic chromatography was used to study the behavior of quinine, propranolol, bilirubin, biliverdin dimethyl ester, and xanthobilirubin methyl ester in single and binary bile salt micelle systems comprised of glycocholic acid and glycodeoxycholic acid. Micelle systems studied had total bile salt concentrations in the range of 10-33 mM with molar ratios of 1:0, 2:1, 1:1, 1:2, and 0:1 glycocholic acid:glycodeoxycholic acid. A pH 8.
View Article and Find Full Text PDFCapillary electrochromatography incorporates features of both capillary electrophoresis and liquid chromatography. Butyl acrylate polymers, cast in-situ with heat initiated polymerization and no retaining frits have been made. Van Deemter plots of chrysene have been examined at a variety of operating temperatures to examine column behavior.
View Article and Find Full Text PDF