J Chromatogr B Analyt Technol Biomed Life Sci
June 2010
A rapid and specific LC-MS/MS based bioanalytical method was developed and validated for the determination of 18-(p-iodophenyl)octadecyl phosphocholine (CLR1401), a novel phosphocholine drug candidate, in rat plasma. The optimal chromatographic behavior of CLR1401 was achieved on a Kromasil silica column (50 mm x 3 mm, 5 microm) under hydrophilic interaction chromatography. The total LC analysis time per injection was 2.
View Article and Find Full Text PDFA sensitive and selective bioanalytical assay was developed and validated for the determination of enantiomeric molindone in human plasma using high-performance liquid chromatography-tandem mass spectrometry along with supported liquid extraction procedures. The chiral separation was evaluated and optimized on macrocyclic antibiotic type chiral stationary phases (CSPs) based on teicoplanin aglycone (Chirobiotic TAG) in polar organic, polar ionic, and reversed-phase mode chromatography, respectively. Complete baseline separation was achieved on a Chirobiotic TAG column under isocratic condition in reversed-phase chromatography.
View Article and Find Full Text PDFTo gauge the experimental variability associated with Biacore analysis, 36 different investigators analyzed a small molecule/enzyme interaction under similar conditions. Acetazolamide (222 g/mol) binding to carbonic anhydrase II (CAII; 30000 Da) was chosen as a model system. Both reagents were stable and their interaction posed a challenge to measure because of the low molecular weight of the analyte and the fast association rate constant.
View Article and Find Full Text PDFWe used surface plasmon resonance biosensors to evaluate the kinetics associated with the initial events of beta-amyloid (Abeta) fibril elongation. Fibrils were immobilized on the sensor chip surface and extended by exposure to soluble Abeta(1-40) peptide. The fibril surfaces bound Congo red, a marker for beta sheet structures, and exhibited a slow linear background decay that is consistent with fibril depolymerization.
View Article and Find Full Text PDFBackground: We examined the usefulness of a new agent in the mapping and dissection of inguinal lymph nodes in the pig. Cy5-cobalamin bioconjugate is blue under visible light and fluoresces brilliant red with laser stimulation. The wavelength of the emitted red light is sufficiently long that it is visible through blood, subcutaneous fat, and fascia.
View Article and Find Full Text PDFSurface plasmon resonance biosensor analysis was used to evaluate the thermodynamics and binding kinetics of naturally occurring and synthetic cobalamins interacting with vitamin B(12) binding proteins. Cyanocobalamin-b-(5-aminopentylamide) was immobilized on a biosensor chip surface to determine the affinity of different cobalamins for transcobalamin, intrinsic factor, and nonintrinsic factor. A solution competition binding assay, in which a surface immobilized cobalamin analog competes with analyte cobalamin for B(12) protein binding, shows that only recombinant human transcobalamin is sensitive to modification of the corrin ring b-propionamide of cyanocobalamin.
View Article and Find Full Text PDF