Data capture systems that acquire continuous hospital-based electrocardiographic (ECG) and physiologic (vital signs) data can foster robust research (i.e., large sample sizes from consecutive patients).
View Article and Find Full Text PDFContinuous electrocardiographic (ECG) monitoring was first introduced into hospitals in the 1960s, initially into critical care, as bedside monitors, and eventually into step-down units with telemetry capabilities. Although the initial use was rather simplistic (ie, heart rate and rhythm assessment), the capabilities of these devices and associated physiologic (vital sign) monitors have expanded considerably. Current bedside monitors now include sophisticated ECG software designed to identify myocardial ischemia (ie, ST-segment monitoring), QT-interval prolongation, and a myriad of other cardiac arrhythmia types.
View Article and Find Full Text PDFBackground: The occurrence of transient myocardial ischemia (TMI) is an important pathology in patients with non-ST elevation acute coronary syndrome (NSTE-ACS), yet studies are scarce regarding when TMI occurs during hospitalization, particularly in relation to invasive coronary angiography (ICA). This study examined: (1) TMI before or after ICA; (2) patient characteristics and ischemic burden by TMI group (before or after ICA); and (3) major in-hospital complications (transfer to critical care, death) and length of stay by TMI group (before or after ICA).
Methods: Secondary data analysis in hospitalized NSTE-ACS patients with TMI event(s) identified from 12-lead electrocardiographic Holter.
Background: Continuous electrocardiographic (ECG) monitoring is used to identify ventricular tachycardia (VT), but false alarms occur frequently.
Objective: The purpose of this study was to assess the rate of 30-day in-hospital mortality associated with VT alerts generated from bedside ECG monitors to those from a new algorithm among intensive care unit (ICU) patients.
Methods: We conducted a retrospective cohort study in consecutive adult ICU patients at an urban academic medical center and compared current bedside monitor VT alerts, VT alerts from a new-unannotated algorithm, and true-annotated VT.
Background: Alarm fatigue in nurses is a major patient safety concern in the intensive care unit. This is caused by exposure to high rates of false and non-actionable alarms. Despite decades of research, the problem persists, leading to stress, burnout, and patient harm resulting from true missed events.
View Article and Find Full Text PDFBackground: In hospitalized patients, QT/QTc (heart rate corrected) prolongation on the electrocardiogram (ECG) increases the risk of torsade de pointes. Manual measurements are time-consuming and often inaccurate. Some bedside monitors automatically and continuously measure QT/QTc; however, the agreement between computerized versus nurse-measured values has not been evaluated.
View Article and Find Full Text PDFIn-hospital electrocardiographic (ECG) monitors are typically configured to alarm for premature ventricular complexes (PVCs) due to the potential association of PVCs with ventricular tachycardia (VT). However, no contemporary hospital-based studies have examined the association of PVCs with VT. Hence, the benefit of PVC monitoring in hospitalized patients is largely unknown.
View Article and Find Full Text PDFBackground: Obstructive Sleep Apnea (OSA) is associated with an increased risk of cardiovascular events, including Acute Coronary Syndrome (ACS). There is conflicting evidence that suggests OSA has a cardioprotective effect (i.e.
View Article and Find Full Text PDFBackground: False ventricular tachycardia (VT) alarms are common during in-hospital electrocardiographic (ECG) monitoring. Prior research shows that the majority of false VT can be attributed to algorithm deficiencies.
Purpose: The purpose of this study was: (1) to describe the creation of a VT database annotated by ECG experts and (2) to determine true vs.
Background: Respiratory rate (RR) alarms alert clinicians to a change in a patient's condition. However, RR alarms are common occurrences. To date, no study has examined RR alarm types and associated patient characteristics, which could guide alarm management strategies.
View Article and Find Full Text PDFAims And Objectives: This study examined the occurrence rate of specific types of premature ventricular complex (PVC) alarms and whether patient demographic and/or clinical characteristics were associated with PVC occurrences.
Background: Because PVCs can signal myocardial irritability, in-hospital electrocardiographic (ECG) monitors are typically configured to alert nurses when they occur. However, PVC alarms are common and can contribute to alarm fatigue.
Background: Impedance pneumography (IP) is the current device-driven method used to measure respiratory rate (RR) in hospitalized patients. However, RR alarms are common and contribute to alarm fatigue. While RR derived from electrocardiographic (ECG) waveforms hold promise, they have not been compared to the IP method.
View Article and Find Full Text PDFBackground: While there are published studies that have examined premature ventricular complexes (PVCs) among patients with and without cardiac disease, there has not been a comprehensive review of the literature examining the diagnostic and prognostic significance of PVCs. This could help guide both community and hospital-based research and clinical practice.
Methods: Scoping review frameworks by Arksey and O'Malley and the Joanna Briggs Institute (JBI) were used.