This technical report describes an approach to the measurement of speech intelligibility for sentences presented in a sound field in the presence of 16-talker babble. More specifically, we detail our (1) selection and preparation of target speech materials, (2) selection and preparation of experimental babble, (3) analog instrumentation, (4) software routines for attenuator control, (5) calibration, (6) experimental subjects, and (7) experimental protocol. In the final section of this report we present speech-intelligibility data from 16 young adults (21-30 yr of age) with normal hearing sensitivity for pure-tone signals.
View Article and Find Full Text PDFThe purpose of the present investigation was to determine whether differences exist in audiometric hearing status between individuals with and without multiple sclerosis (MS) and between individuals with relapsing-remitting MS (RRMS) and individuals with secondary progressive MS (SPMS). Forty-seven subjects with MS (26 with RRMS and 21 with SPMS) and forty-nine control subjects without MS completed both a comprehensive case-history questionnaire and a conventional hearing evaluation. Statistical analyses, accounting for the potential confounding factors of age, sex, noise exposure, and use of ototoxic medications, revealed significant differences in hearing thresholds between subjects with and without MS at select audiometric test frequencies (p < 0.
View Article and Find Full Text PDF