Rapid solution exchange on a solid-supported membrane (SSM) is investigated using fluidic structures and a solid-supported membrane of 1 mm diameter in wall jet geometry. The flow is analyzed with a new technique based on specific ion interactions with the surface combined with an electrical measurement. The critical parameters affecting the time course of the solution exchange and the transfer function describing the time resolution of the SSM system are determined.