Publications by authors named "Michel Reijnen"

: To study the influence of diabetes mellitus (DM) and metformin treatment on aneurysm sac remodeling after endovascular aneurysm repair (EVAR). : A retrospective single-center cohort analysis was conducted on consecutive patients who underwent elective EVAR for an infrarenal abdominal aortic aneurysm (AAA) between January 2011 and December 2021. Differences between study groups were analyzed and Kaplan-Meier analysis were employed to describe overall and reintervention-free survival.

View Article and Find Full Text PDF

Objective: This retrospective, multicentre, observational cohort study aimed to assess the long term quality of life, health status, and residential destination after successful treatment of a ruptured abdominal aortic aneurysm (rAAA) treated with endovascular aneurysm repair (EVAR) or open surgical repair (OSR).

Methods: Consecutive patients from five large teaching hospitals with a computed tomography confirmed rAAA from 1 January 2013 to 31 December 2018 were included. Mortality, morbidity, discharge destination, and residential destination through follow up were registered.

View Article and Find Full Text PDF

Purpose: To evaluate retrospectively the 2-year outcomes of the Gore Excluder Iliac Branch Endoprosthesis (IBE) in patients with and without coexisting hypogastric artery (HA) aneurysms in a large contemporary multicentric European experience using dedicated bridging devices.

Methods: The study included all consecutive patients treated at participating institutions with the Gore Excluder IBE device who received a covered stent (i.e.

View Article and Find Full Text PDF

Objective: Helical stents have been developed to treat peripheral arterial disease (PAD) in the superficial femoral artery (SFA), with the premise that their particular geometry could promote swirling flow in the blood. The aim of this work is to provide evidence on the existence of this swirling flow by quantifying its signatures.

Materials And Methods: This study consists of in vitro and in vivo parts.

View Article and Find Full Text PDF

Background: A major lower limb amputation (LLA) for dysvascular disease carries the risk of disturbed wound healing necessitating reamputation at a higher level. A reamputation causes a delay in prosthetic fitting and recovery of walking ability. The combination of a prolonged open wound and inability to walk can worsen the physical and psychological situation.

View Article and Find Full Text PDF

Objective: Local flow dynamics impact atherosclerosis yet are difficult to quantify with conventional ultrasound techniques. This study investigates the performance of ultrasound vector flow imaging (US-VFI) with and without ultrasound contrast agents in the healthy femoral bifurcation.

Methods: High-frame-rate ultrasound data with incremental acoustic outputs were acquired in the femoral bifurcations of 20 healthy subjects before (50V) and after contrast injection (2V, 5V and 10V).

View Article and Find Full Text PDF

Background: No evaluation of the quality of different carotid guidelines using validated scales has been performed to date. The present study aims to analyze 3 carotid stenosis guidelines, apprizing their quality and reporting using validated tools.

Methods: A survey-based assessment of the quality of the European Society for Vascular Surgery (ESVS) 2023, European Stroke Organisation (ESO) 2021, and the Society for Vascular Surgery (SVS) 2021 carotid stenosis guidelines, was performed by 43 vascular surgeons, cardiologists, neurologist or interventional radiologists using 2 validated appraisal tools for quality and reporting guidelines, the AGREE II instrument and the RIGHT statement.

View Article and Find Full Text PDF

Objective: One year aneurysm sac dynamics after endovascular abdominal aortic aneurysm repair (EVAR) were independently associated with a greater all cause mortality risk in prior registry studies but were limited in completeness and granularity. This retrospective analysis aimed to study the impact of sac dynamics on survival within the Endurant Stent Graft Global Registry (ENGAGE) with five year follow up.

Methods: A total of 1 263 subjects were enrolled in the ENGAGE Registry between March 2009 and April 2011.

View Article and Find Full Text PDF

Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV).

Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow.

View Article and Find Full Text PDF

Objective: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck.

Methods: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry.

View Article and Find Full Text PDF

Objective: In two randomized controlled trials, the outcomes of endovascular treatment of complex femoropopliteal arterial lesions were compared with bypass surgery and considered a valid alternative treatment. The aim of this study was to compare both endovascular treatment options with the hypothesis that implantation of heparin-bonded self-expanding covered stents (Viabahn [SECS]) or drug-eluting stents (ZilverPTX [DES]) are related to similar clinical outcomes at 1-year follow-up.

Methods: In a post-hoc analysis, the SuperB trial and Zilverpass databases were merged.

View Article and Find Full Text PDF

Objective: To assess the impact of heparin-bonded endoprosthesis compared with femoropopliteal bypass on key hospital resources and revenues up to 1-year follow-up.

Design: A 2-arm scenario resource consumption data analysis was modeled based on a multicentre prospective randomized controlled trial.

Setting: Six centers in the Netherlands.

View Article and Find Full Text PDF

Background: The study aims to describe midterm outcomes following treatment of infrarenal abdominal aortic aneurysms (AAAs) with short necks by endosutured aneurysm repair using the Heli-FX EndoAnchor system.

Methods: This is a retrospective study of prospectively collected data from 9 vascular surgery departments between June 2010 and December 2019, including treated AAAs with neck lengths ≤10 mm. The decision for the use of EndoAnchors was made by the treating surgeon or multidisciplinary aortic committee according to each center's practice.

View Article and Find Full Text PDF

Objective: This study evaluated the long term outcomes of endovascular aneurysm repair using the Gore Excluder Low Permeability (LP) endoprosthesis across high volume Dutch hospitals.

Methods: A retrospective analysis was conducted of patients treated with the Excluder LP for infrarenal abdominal aortic aneurysm (AAA) in four hospitals between 2004 and 2017. Primary outcomes were overall survival, freedom from re-interventions (overall, inside and outside instructions for use, IFU), and AAA sac dynamics: growth (> 5 mm), stabilisation, and regression (< 5 mm).

View Article and Find Full Text PDF

Objective: This study aims to compare the 5-year outcomes of endoluminal bypass (EB) using heparin-bonded self-expanding covered stents versus bypass surgery for extensive femoropopliteal disease, including technical and clinical outcomes and health status.

Background: The surgical femoropopliteal bypass was the gold standard to treat peripheral arterial disease (PAD) for decades; however, endovascular treatment modalities are now recommended for most femoropopliteal lesions. One-year data of a randomized controlled trial comparing EB with surgical bypass (SB) have shown a faster recovery, less morbidity, and comparable patency rates between the two techniques.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the use of an upside-down Gore Excluder contralateral leg endoprosthesis to address diameter differences in the treatment of aortoiliac aneurysms, focusing on its applicability and safety rather than the technique itself.
  • A total of 31 patients were enrolled, with most undergoing primary procedures for various types of aneurysms, while a smaller percentage had previous interventions.
  • Results showed that the technique has a low complication rate, with only a few needing further intervention, and a 3.3% rate of aneurysm-related mortality, indicating it is a valuable method for effective aneurysm management.
View Article and Find Full Text PDF

Objective: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure.

Methods: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands.

View Article and Find Full Text PDF

Purpose: To identify potential hemodynamic predictors for limb thrombosis (LT) following endovascular aneurysm repair with the Anaconda endograft in a patient-specific phantom.

Materials And Methods: A thin-walled flow phantom, based on a patient's aortic anatomy and treated with an Anaconda endograft, that presented with a left-sided LT was fabricated. Contrast-enhanced ultrasound particle image velocimetry was performed to quantify time-resolved velocity fields.

View Article and Find Full Text PDF

Introduction: Cardiovascular diseases (CVD) are the leading cause of death globally. Inflammation is an important driver of CVD where tissue damage may lead to the formation of deadly thrombi. Therefore, antithrombotic drugs, such as platelet inhibitors, are crucial for secondary risk prevention in coronary artery disease (CAD) and peripheral artery disease (PAD).

View Article and Find Full Text PDF

Background: The recommendations for the use of and selection of covered stent grafts in patients with aortoiliac occlusive disease are limited.

Objective: The GORE VBX FORWARD clinical study aims to demonstrate the superiority of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX device) for primary patency when compared to bare metal stenting (BMS) for the treatment of complex iliac artery occlusive disease.

Methods: A prospective, multicenter, randomized control study in the United States, European Union, United Kingdom, Australia, and New Zealand will enroll patients with symptomatic, complex iliac artery occlusive disease.

View Article and Find Full Text PDF

Objective: The goal of this study was to determine to what extent aortic stent graft motion quantification is comparable between electrocardiogram (ECG)-gated computed tomography (CT) scans with reconstructions into 8 and 10 cardiac phases on CT scanners from two different vendors.

Methods: An experimental setup that induces motion of an aortic stent graft, according to a predefined aortic blood pressure wave, was placed in two CT scanners of different vendors. The stent graft motion was captured using an ECG-gated CT technique and quantified using dedicated analysis algorithms.

View Article and Find Full Text PDF

Objective: The performance of fenestrated endovascular aortic aneurysm repair (FEVAR) may be compromised by complications related to the dynamic vascular environment. The aim of this study was to analyze the behavior of FEVAR bridging stent configurations during the cardiac cycle and during follow-up to improve our understanding on treatment durability.

Design: Twenty-one patients presenting with complex abdominal aortic aneurysms (AAAs; 9 juxtarenal/6 pararenal/3 paravisceral/1 thoracoabdominal aortic aneurysm type IV), treated with a fenestrated Anaconda (Terumo Aortic, Inchinnan, Scotland, UK) with Advanta V12 bridging stents (Getinge, Merrimack, NH, USA), were prospectively enrolled in a multicenter observational cohort study and underwent electrocardiogram (ECG)-gated computed tomographic angiography (CTA) preoperatively, at discharge, 7-week, and 12-month follow-ups.

View Article and Find Full Text PDF

Objective: Type II endoleak is the most frequent complication after endovascular abdominal aneurysm repair. Polytetrafluoroethylene and polyester (PE) are the two most commonly used graft materials in endovascular aneurysm repair (EVAR) devices. Biological properties of the material might influence the appearance and persistence of type II endoleak (T2EL).

View Article and Find Full Text PDF

Background: Mechanochemical endovenous ablation (MOCA) was introduced to treat superficial venous insufficiency of the lower leg with less pain and haematoma. Long-term outcome is still lacking. The purpose was to report long-term outcome and to analyse possible predictors for failure.

View Article and Find Full Text PDF

Purpose: To summarize the 5-year outcomes of drug-coated balloon (DCB) for the treatment of femoropopliteal lesions in patients with diabetes mellitus (DM) or chronic limb-threatening ischemia (CLTI) compared to non-DM and intermittent claudication (IC).

Methods: The IN.PACT Global study was a real-world prospective, multicenter, international, single-arm study that enrolled 1535 participants.

View Article and Find Full Text PDF