Publications by authors named "Michel D'Amours"

Accounting for brachytherapy applicator attenuation is part of the recommendations from the recent report of AAPM Task Group 186. To do so, model based dose calculation algorithms require accurate modelling of the applicator geometry. This can be non-trivial in the case of irregularly shaped applicators such as the Fletcher Williamson gynaecological applicator or balloon applicators with possibly irregular shapes employed in accelerated partial breast irradiation (APBI) performed using electronic brachytherapy sources (EBS).

View Article and Find Full Text PDF

Purpose: To assess the dosimetric effects of the presence of the applicator, air pockets in clinical target volume (CTV) and OARs along with tissue heterogeneities using the Monte Carlo (MC) method in high dose rate (HDR) gynecologic interstitial brachytherapy with a Syed-Neblett template.

Methods And Materials: The CT based dosimetry has been achieved with the Geant4 MC toolkit version 9.2.

View Article and Find Full Text PDF

A problem faced by all Monte Carlo (MC) particle transport codes is how to handle overlapping geometries. The Geant4 MC toolkit allows the user to create parallel geometries within a single application. In Geant4 the standard mass-containing geometry is defined in a simulation volume called the World Volume.

View Article and Find Full Text PDF

Purpose: To establish the accuracy and speed of bGPUMCD, a GPU-oriented Monte Carlo code used for high dose rate brachytherapy dose calculations. The first objective is to evaluate the time required for dose calculation when full Monte Carlo generated dose distribution kernels are used for plan optimization. The second objective is to assess the accuracy and speed when recalculating pre-optimized plans, consisting of many dwell positions.

View Article and Find Full Text PDF

Purpose: The characteristics of the radionuclide (57)Co make it interesting for use as a brachytherapy source. (57)Co combines a possible high specific activity with the emission of relatively low-energy photons and a half-life (272 days) suitable for regular source exchanges in an afterloader. (57)Co decays by electron capture to the stable (57)Fe with emission of 136 and 122 keV photons.

View Article and Find Full Text PDF

Purpose: To perform absorbed dose calculations based on Monte Carlo simulations for a hypothetical (170)Tm source and to investigate the influence of encapsulating material on the energy spectrum of the emitted electrons and photons.

Methods: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of (170)Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models.

View Article and Find Full Text PDF

Purpose: Brachytherapy planning software relies on the Task Group report 43 dosimetry formalism. This formalism, based on a water approximation, neglects various heterogeneous materials present during treatment. Various studies have suggested that these heterogeneities should be taken into account to improve the treatment quality.

View Article and Find Full Text PDF

Standard algorithms for postimplant analysis of transperineal interstitial permanent prostate brachytherapy (TIPPB) are based on AAPM Task Group 43 formalism (TG-43), which makes use of a world entirely made of water. This entails an assignment of the prostate, surrounding organs at risk, as well as all brachytherapy seeds present in a permanent prostate implant to water. Brachytherapy seeds are generally made from high atomic number materials.

View Article and Find Full Text PDF

Purpose: To use the Monte Carlo (MC) method as a dose calculation engine for postimplant dosimetry. To compare the results with clinically approved data for a sample of 28 patients. Two effects not taken into account by the clinical calculation, interseed attenuation and tissue composition, are being specifically investigated.

View Article and Find Full Text PDF