Publications by authors named "Michael Y K Wee"

Objective: This work is to build upon the concept of matching a person's weight, height and age to their overall body shape to create an adjustable three-dimensional model. A versatile and accurate predictor of body size and shape and ligament thickness is required to improve simulation for medical procedures. A model which is adjustable for any size, shape, body mass, age or height would provide ability to simulate procedures on patients of various body compositions.

View Article and Find Full Text PDF

Objective: to identify the extent to which Early Warning Systems (EWS) are used by midwives in the United Kingdom (UK), the maternity settings they are used in, physiological parameters used to 'trigger' referral, training provision, barriers to implementation and role in preventing maternal morbidity.

Design: cross-sectional survey of heads of midwifery services. An email questionnaire was sent in September 2012.

View Article and Find Full Text PDF

The amount of pressure exerted on the syringe and the depth of needle insertion are the two key factors for successfully carrying out epidural procedure. The force feedback from the syringe plunger is helpful in judging the loss of pressure, and the depth of the needle insertion is crucial in identifying when the needle is precisely placed in the epidural space. This article presents the development of two novel wireless devices to measure these parameters to precisely guide the needle placement in the epidural space.

View Article and Find Full Text PDF

Thirty-one central neural blockade simulators have been implemented into clinical practice over the last thirty years either commercially or for research. This review aims to provide a detailed evaluation of why we need epidural and spinal simulators in the first instance and then draws comparisons between computer-based and manikin-based simulators. This review covers thirty-one simulators in total; sixteen of which are solely epidural simulators, nine are for epidural plus spinal or lumbar puncture simulation, and six, which are solely lumbar puncture simulators.

View Article and Find Full Text PDF

Background: Intramuscular pethidine is routinely used throughout the UK for labour analgesia. Studies have suggested that pethidine provides little pain relief in labour and has a number of side effects affecting mother and neonate. It can cause nausea, vomiting and dysphoria in mothers and can cause reduced fetal heart rate variability and accelerations.

View Article and Find Full Text PDF