The purpose of this study was to present a theoretical analysis of how the presence of bone in interstitial brachytherapy affects dose rate distributions. This study was carried out using a Monte Carlo simulation of the dose distribution in homogeneous medium for 3 commonly used brachytherapy seeds. The 3 seeds investigated in this study are iridium-192 (192Ir) iodine-125 (125I), and palladium-103 (103Pd).