Delayed union and non-union of fractures continue to be a major problem in trauma and orthopedic surgery. These cases are challenging for the surgeon. In addition, these patients suffer from multiple surgeries, pain and disability.
View Article and Find Full Text PDFHarvesting of tricortical bone graft from the iliac crest is an integral part of bone defect reconstruction in orthopaedic surgery. There are several options for filling the iliac crest defect area to avoid hematoma, pain, hernias and cosmetic issues, including different gelatin-based and other alternative biomaterials. Recently, a novel rattan-wood based not-sintered hydroxyapatite and beta-tricalcium phosphate material (b.
View Article and Find Full Text PDFPurpose: In the last decades, total elbow arthroplasty, elbow osteosynthesis and revision surgery have been more popularized. The study aimed to assess the course of the anconeus branch of the radial nerve in relation to two variations of the lateral para-olecranon approach, considering iatrogenic nerve injuries.
Methods: The study consisted of 120 upper extremities from 60 Thiel-embalmed human specimens.
We sought to evaluate the findings of our anatomically landmarks based mini-open procedure (MCTR) through a palmar approach and to compare its outcome and practicability to the conventional method (OCTR). The study consisted of 100 matched patients (n = 50 MCTR, n = 50 OCTR) with a minimum follow-up of three years. The outcome was characterized via the Disabilities of Arm, Shoulder and Hand Score (DASH), Symptom Severity Scale (SSS), Functional Status Scale (FSC), and Visual Analogue Scale (VAS).
View Article and Find Full Text PDFBackground: A new locking screw technology, named variable fixation, has been developed aiming at promoting bone callus formation providing initial rigid fixation followed by progressive fracture gap dynamisation. In this study, we compared bone callus formation in osteotomies stabilized with standard locking fixation against that of osteotomies stabilized with variable fixation in an established tibia ovine model.
Methods: A 3 mm tibial transverse osteotomy gap was stabilized in three groups of six female sheep each with a locking plate and either 1) standard fixation in both segments (group LS) or 2) variable fixation in the proximal and standard fixation in the distal bone segment (group VFLS) or 3) variable fixation in both segments (group VFLS).
Cartilage defects represent an increasing pathology among active individuals that affects the ability to contribute to sports and daily life. Cell therapy, such as autologous chondrocyte implantation (ACI), is a widespread option to treat larger cartilage defects still lacking standardization of in vitro cell culture parameters. We hypothesize that mRNA expression of cytokines and proteases before and after ACI is influenced by in vitro parameters: cell-passage, cell-density and membrane-holding time.
View Article and Find Full Text PDFBackground: Non-steroidal anti-inflammatory drugs are commonly used to reduce pain and inflammation in orthopaedic patients. Selective cyclooxygenase-2 (COX-2) inhibitors have been developed to minimize drug-specific side effects. However, they are suspected to impair both bone and tendon healing.
View Article and Find Full Text PDFA study was undertaken to examine the presence of the distal oblique bundle of the forearm in a large sample in order to describe its true prevalence. The study sample consisted of 200 cadaveric forearms. Fifteen were excluded due to defects in the distal interosseous membrane.
View Article and Find Full Text PDFPurpose: Varus failure is one of the most common failure modes following surgical treatment of proximal humeral fractures. Straight antegrade nails (SAN) theoretically provide increased stability by anchoring to the densest zone of the proximal humerus (subchondral zone) with the end of the nail. The aim of this study was to biomechanically investigate the characteristics of this "proximal anchoring point" (PAP).
View Article and Find Full Text PDFObjective: Multiple trauma is often accompanied by systemic inflammatory response syndrome (SIRS). The aim of this study was to investigate the impact of polymeric plasma substitutes on the development of SIRS or sepsis.
Methods: We included 2969 patients aged ≥16 years with an Injury Severity Score (ISS) >16 in this study.
Background: The correction of coagulopathy with fresh frozen plasma (FFP) is one of the main issues in the treatment of multiple-injured patients. Infectious and septic complications contribute to an adverse outcome in multiple-injured patients. Here, we investigated the role of FFP in the development of inflammatory complications given within the first 48 hours.
View Article and Find Full Text PDFBackground Aims: Fractures with a critical size bone defect (e.g., open fracture with segmental bone loss) are associated with high rates of delayed union and non-union.
View Article and Find Full Text PDFBackground: Locking plates are widely used in fracture fixation, mainly for meta-diaphyseal fractures, comminuted fractures, fractures with a critical-size bone defect, periprosthetic fractures, osteotomies, and fractures in osteoporotic bone. The aim of this animal study was to evaluate the effect on bone-healing of dynamization of locking plate constructs by means of new 5.0-mm dynamic locking screws (in the DLS group), which allow near-cortex micromotion, compared with a more rigid construct utilizing standard bicortical locking-head screws (in the LS group).
View Article and Find Full Text PDFBackground: Loss of reduction and screw perforation causes high failure rates in the treatment of proximal humerus fractures. The purpose of the present study was to evaluate the early postoperative complications using modern Dynamic Locking Screws (DLS 3.7) for plating of proximal humerus fractures.
View Article and Find Full Text PDFBackground: Obesity is a growing problem in western societies. The aim of this retrospective cohort study was to determine the association between the overweight and obese polytrauma patients and pneumonia after injury.
Methods: A total of 628 patients with an Injury Severity Score (ISS) of 16 or greater and 16 years or older were included in this retrospective study.
In this in vivo study a new generation of locking screws was tested. The design of the dynamic locking screw (DLS) enables the dynamisation of the cortex underneath the plate (cis-cortex) and, therefore, allows almost parallel interfragmentary closure of the fracture gap. A 45° angle osteotomy was performed unilaterally on the tibia of 37 sheep.
View Article and Find Full Text PDFFunctional outcome after retrograde femoral intramedullary nailing was investigated in 35 patients older than 60 years (mean, 86 years) with 36 fractures, comprising 15 (41.7%) shaft and 21 (58.3%) distal fractures; overall, 7 (19.
View Article and Find Full Text PDFIntroduction: Insufficient primary stability is still reported for proximal humerus fractures in elderly patients. Fixation stability could be improved by aiming locking screws at bone volumes with better properties. The aims of this study were to investigate the bone regions engaged by the locking screws of a Proximal Humeral Nail (MultiLoc PHN), and to evaluate the influence of peri-screw bone quality on bone-nail construct stability.
View Article and Find Full Text PDFBackground: Osteosynthesis of unstable proximal humerus fractures still remains challenging. The aim of this study was to investigate two intramedullary nailing techniques with different locking options in a three-part fracture model and prove whether two new fixation concepts, introducing additional locking screw-in-screws inserted through the head of the proximal screws, and a calcar screw, provide better stability.
Methods: A biomechanical testing model for three-part proximal humerus fractures including cyclic axial loading with increasing peak load and simultaneous pulling forces at the rotator cuff was used to test 12 pairs of human cadaver humeri, assigned to four groups and instrumented with either Targon PH (T1) or MultiLoc PHN in 3 different configurations (standard M1; two additional screw-in-screw M2; one additional calcar screw and two screw-in-screw M3).
Background: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep.
Methods: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants.
Background: Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing.
Study Design: In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested using a 45° oblique osteotomy simulating simple fracture pattern. 60 Swiss Alpine sheep where assigned to 5 different groups with 12 sheep each (Group 1: interfragmentary lag screw and an LCP fixed with standard cortex screws as neutralisation plate; Group 2: interfragmentary lag screw and LCP with locking head screws; Group 3: compression plate technique (hybrid construct); Group 4: internal fixator without fracture gap; Group 5: internal fixator with 3mm gap at the osteotomy site).
Background: The optimal surgical treatment for displaced proximal humeral fractures is still controversial. A new implant for the treatment of three-part fractures has been recently designed. It supplements the existing Expert Humeral Nail with a locking plate.
View Article and Find Full Text PDFOper Orthop Traumatol
February 2005
Objective: Stable fixation of unstable proximal humerus fractures until bony consolidation. Early mobilization of the shoulder and early active rehabilitation program to ensure a good functional outcome and a good restoration of the activities of daily living.
Indications: Unstable two-, three- and four-part fractures of the proximal humerus (classified according to the AO classification as: 11-A2, A3, B1, B2, B3, C1, C2, C3).