Publications by authors named "Michael Moll"

Device simulation plays a crucial role in complementing experimental device characterisation by enabling deeper understanding of internal physical processes. However, for simulations to be trusted, experimental validation is essential to confirm the accuracy of the conclusions drawn. In the framework of semiconductor detector characterisation, one powerful tool for such validation is the Two Photon Absorption-Transient Current Technique (TPA-TCT), which allows for highly precise, three-dimensional spatially-resolved characterisation of semiconductor detectors.

View Article and Find Full Text PDF

The Two-Photon Absorption-Transient Current Technique (TPA-TCT) is a device characterisation technique that enables three-dimensional spatial resolution. Laser light in the quadratic absorption regime is employed to generate excess charge carriers only in a small volume around the focal spot. The drift of the excess charge carriers is studied to obtain information about the device under test.

View Article and Find Full Text PDF

The EOS™2D/3D system is a low-dose, 3D imaging system that utilizes two perpendicular X-ray beams to create simultaneous frontal and lateral images of the body. This is a useful modality to assess spinal pathologies. However, due to the slow imaging acquisition time up to 25 s, motion artifacts (MA) frequently occur.

View Article and Find Full Text PDF

The two photon absorption-transient current technique (TPA-TCT) was used to investigate a silicon strip detector with illumination from the top. Measurement and analysis techniques for the TPA-TCT of segmented devices are presented and discussed using a passive strip CMOS detector and a standard strip detector as an example. The influence of laser beam clipping and reflection is shown, and a method that allows to compensate these intensity-related effects for investigation of the electric field is introduced and successfully employed.

View Article and Find Full Text PDF

A fiber laser system emitting ultrashort femtosecond pulses at 1550 nm with configurable properties has been developed as an excitation source for the two-photon absorption transient current technique (TPA-TCT). The modules of the system are designed to provide the optical specifications required at the output for localized characterization of semiconductor radiation detectors: variation of pulse energy between 10 nJ and 10 , variation of the pulse repetition rate from 8.2 MHz to single shot, and variation of pulse duration between 300 and 600 fs.

View Article and Find Full Text PDF

Background: High-frequency, rapid-turnaround severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing continues to be proposed as a way of efficiently identifying and mitigating transmission in congregate settings. However, 2 SARS-CoV-2 outbreaks occurred among intercollegiate university athletic programs during the fall 2020 semester, despite mandatory directly observed daily antigen testing.

Methods: During the fall 2020 semester, athletes and staff in both programs were tested daily using Quidel's Sofia SARS Antigen Fluorescent Immunoassay, with positive antigen results requiring confirmatory testing with real-time reverse-transcription polymerase chain reaction.

View Article and Find Full Text PDF

Background: High frequency, rapid turnaround SARS-CoV-2 testing continues to be proposed as a way of efficiently identifying and mitigating transmission in congregate settings. However, two SARS-CoV-2 outbreaks occurred among intercollegiate university athletic programs during the fall 2020 semester despite mandatory directly observed daily antigen testing.

Methods: During the fall 2020 semester, athletes and staff in both programs were tested daily using Quidel's Sofia SARS Antigen Fluorescent Immunoassay (FIA), with positive antigen results requiring confirmatory testing with real-time reverse transcription polymerase chain reaction (RT-PCR).

View Article and Find Full Text PDF