Publications by authors named "Michael M Morlock"

Aims: Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model.

View Article and Find Full Text PDF

The implantation of uncemented prostheses requires the application of sufficient forces to achieve a press-fit of the implant in the bone. Excessive forces have to be omitted to limit bone damage. Force measurements along the force transmission path between mallet and implant are frequently used to investigate this trade-off.

View Article and Find Full Text PDF

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence.

View Article and Find Full Text PDF

Three-dimensional body scanners are attracting increasing interest in various application areas. To evaluate their accuracy, their 3D point clouds must be compared to a reference system by using a reference object. Since different scanning systems use different coordinate systems, an alignment is required for their evaluation.

View Article and Find Full Text PDF

Introduction: In revision surgery, modular implant components allow the surgeon to tailor the characteristics of the implant to the bone situation. Relative motion can occur at the tapered modular connection, leading to fretting corrosion and subsequent biological reactions, particularly due to poor assembly and contamination of the tapered connection. The aim of this study was to demonstrate whether incomplete assembly and inadvertent contamination of the modular taper causes a change in junction strength.

View Article and Find Full Text PDF

The ideal stem size and stem position is important for the success of total hip arthroplasty, since it can affect early implant loosening and periprosthetic fractures (PPF). This study aimed to investigate how small deviations from the ideal stem size and position influences the PPF risk and primary stability. Six experienced surgeons performed preoperative templating based on which the benchmark size for each femur was determined.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates whether adding wider and less prominent splines to a revision hip stem can improve its stability and prevent complications that often lead to hip revision surgeries.
  • Experimental methods included a comparison of torsional strength between a standard revision stem and a prototype with additional splines, using human femurs to test their effectiveness.
  • Results showed that the prototype design had significantly greater cortical contact and torsional strength than the standard model, suggesting that spline modifications could enhance hip implant performance.
View Article and Find Full Text PDF

Background: Patient-specific 3D-printed miniplates for free flap fixation in mandibular reconstruction were recently associated with enhanced osseous union. Higher mechanical strains resulting from these plates are discussed as reasons, but biomechanical studies are missing. This study aims to examine, whether patient-specific 3D-printed miniplates provide an increased interosteotomy movement (IOM) and lower stiffness compared with reconstruction plates.

View Article and Find Full Text PDF

The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure. Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference.

View Article and Find Full Text PDF

Background: Instability constitutes the main reason for revision hip arthroplasties. Modified polyethylene liners are designed to improve the stability of a hip replacement. In July 2022 The Bone & Joint Journal published a study with data of the German Arthroplasty Registry (EPRD).

View Article and Find Full Text PDF

Aseptic loosening is one of the major reasons for re-revisions of cementless revision stems. Insufficient primary stability is associated with bone characteristics and the surgical process. This study aimed to investigate how femur morphology and preparation methods influence the primary stability of revision stems.

View Article and Find Full Text PDF

Sufficient primary stability is one of the most important prerequisites for successful osseointegration of cementless implants. Bone grafts, densification and compaction methods have proven clinically successful, but the related effects and causes have not been systematically investigated. Postoperatively, the frictional properties of the bone-implant interface determine the amount of tolerable shear stress.

View Article and Find Full Text PDF

Background: The influence of the surgical process on implant loosening and periprosthetic fractures (PPF) as major complications in uncemented total hip arthroplasty (THA) has rarely been studied because of the difficulty in quantification. Meanwhile, registry analyses have clearly shown a decrease in complications with increasing experience. The goal of this study was to determine the extent of variability in THA stem implantation between highly experienced surgeons with respect to implant size, position, press-fit, contact area, primary stability, and the effect of using a powered impaction tool.

View Article and Find Full Text PDF

Insufficient primary stability of acetabular hip cups is a complication resulting in early cup loosening. Available cup designs vary in terms of wall thickness, potentially affecting implant fixation. This study investigated the influence of different wall thicknesses on the implantation process and the resulting primary stability using excised human acetabula.

View Article and Find Full Text PDF

We report a case of extended osteolysis, requiring a third revision of the left hip in an 85-year-old man 46 years after index operation. Major polyethylene (PE) wear occurred due to a missmatched combination of a bipolar Hastings head with a PE liner and head damage of the originally maintained stem. This case demonstrates that bipolar heads should not be used with PE cup liners since the respective bearing diameters cannot be guaranteed to match due to missing specifications.

View Article and Find Full Text PDF

Background: Gross taper failure (GTF) is a rare but catastrophic failure mode of the head-stem-taper junction of hip prostheses, facilitated by massive material loss. GTF is a two stage process initiated by corrosion leading to head bottoming out, followed by abrasive wear due to the head rotating on the stem. The purpose of this study was to reproduce the clinical failure patterns and to determine the material loss during simulated gait.

View Article and Find Full Text PDF

Objective: Loosening of pedicle screws is a frequently observed complication in spinal surgery. Because additional stabilization procedures such as cement augmentation or lengthening of the instrumentation involve relevant risks, optimal stability of the primarily implanted pedicle screw is of essential importance. The aim of the present study was to investigate the effect of increasing the screw diameter on pedicle screw stability.

View Article and Find Full Text PDF

Background: Fractures of modular revision stems at the taper junction are rare but severe clinical problems. The purpose of this study was the estimation of taper loading to identify configurations which are less prone to failure.

Methods: A parametrical analytical 3-D model was developed to determine the influence of neck segment length, offset and anteversion on the loading at the modular taper junction between neck segment and stem.

View Article and Find Full Text PDF

Age estimation is a crucial element of forensic medicine to assess the chronological age of living individuals without or lacking valid legal documentation. Methods used in practice are labor-intensive, subjective, and frequently comprise radiation exposure. Recently, also non-invasive methods using magnetic resonance imaging (MRI) have evaluated and confirmed a correlation between growth plate ossification in long bones and the chronological age of young subjects.

View Article and Find Full Text PDF

The focus on taper corrosion in modular hip arthroplasty increased around 2007 as a result of clinical problems with large-head metal-on-metal (MoM) bearings on standard stems. Corrosion problems with bi-modular primary hip stems focused attention on this issue even more.Factors increasing the risk of taper corrosion were identified in laboratory and retrieval studies: stiffness of the stem neck, taper diameter and design, head diameter, offset, assembly force, head and stem material and loading.

View Article and Find Full Text PDF

Purpose: Inadequate anchoring of pedicle screws in vertebrae with poor bone quality is a major problem in spine surgery. The aim was to evaluate whether a modified thread in the area of the pedicle could significantly improve the pedicle screw fatigue strength.

Methods: Fourteen human cadaveric vertebral bodies (L2 and L3) were used for in vitro testing.

View Article and Find Full Text PDF

Study Design: Biomechanical study.

Objectives: Failure of pedicle screws is a major problem in spinal surgery not only postoperatively, but also intraoperatively. The aim of this study was to evaluate whether cement augmentation may restore mounting of initially loosened pedicle screws.

View Article and Find Full Text PDF

Background: Titanium plate fixation of free flaps in mandibular reconstruction involves complications such as osseous non-union or imaging artefacts. Interosteotomy movement (IOM) is known to affect bone healing. This study aimed to compare IOM and mechanical integrity of four different fixation systems in a mandible reconstruction model.

View Article and Find Full Text PDF
Article Synopsis
  • A case study is presented involving an 81-year-old man who experienced gross taper failure (GTF) in his hip implant 14 years after surgery, leading to acute pain and leg shortening.
  • X-rays revealed that the implant's head had become detached from the stem, and the stem needed to be revised due to significant damage.
  • The case highlights that GTF can occur regardless of the design or material of the implant, and a high activity level may contribute to this type of failure.
View Article and Find Full Text PDF

Study Design: Biomechanical.

Objective: This study evaluates the biomechanical properties of lag-screws used in vertebral pincer fractures at the thoracolumbar junction.

Methods: Pincer fractures were created in 18 bisegmental human specimens.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionp788qdnpqio35nclagmui6l9qhi8e3gu): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once