Publications by authors named "Michael Lovelock"

Purpose: End-to-end testing (E2E) is a necessary process for assessing the readiness of the stereotactic radiosurgery (SRS) program and annual QA of an SRS system according to the AAPM MPPG 9a. This study investigates the differences between using a new SRS MapCHECK (SRSMC) system and an anthropomorphic phantom film-based system in a large network with different SRS delivery techniques.

Methods And Materials: Three SRS capable Linacs (Varian Medical Systems, Palo Alto, CA) at three different regional sites were chosen to represent a hospital network, a Trilogy with an M120 multi-leaf collimator (MLC), a TrueBeam with an M120 MLC, and a TrueBeam Stx with an HD120 MLC.

View Article and Find Full Text PDF

Purpose: Our purpose was to assess the suitability of airway-implanted internal fiducial markers and an external surrogate of respiratory motion for motion management during radiation therapy of lung tumors.

Methods And Materials: We analyzed 4-dimensional computed tomography scans acquired during radiation therapy simulation for 28 patients with lung tumors who had anchored fiducial markers bronchoscopically implanted inside small airways in or near the tumor in a prospective trial. We used a linear mixed model to build population-based correlative models of tumor and surrogate motion.

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy of using bronchoscopically implanted anchored electromagnetic transponders (EMTs) as surrogates for 1) tumor position and 2) repeatability of lung inflation during deep-inspiration breath-hold (DIBH) lung radiotherapy.

Methods: Forty-one patients treated with either hypofractionated (HF) or conventional (CF) lung radiotherapy on an IRB-approved prospective protocol using coached DIBH were evaluated for this study. Three anchored EMTs were bronchoscopically implanted into small airways near or within the tumor.

View Article and Find Full Text PDF

Introduction: To investigate the impact of partial lateral scatter (LS), backscatter (BS) and presence of air gaps on optically stimulated luminescence dosimeter (OSLD) measurements in an acrylic miniphantom used for dosimetry audit on the 1.5 T magnetic resonance-linear accelerator (MR-linac) system.

Methods: The following irradiation geometries were investigated using OSLDs, A26 MR/A12 MR ion chamber (IC), and Monaco Monte Carlo system: (a) IC/OSLD in an acrylic miniphantom (partial LS, partial BS), (b) IC/OSLD in a miniphantom placed on a solid water (SW) stack at a depth of 1.

View Article and Find Full Text PDF

Deep inspiration breath hold (DIBH) has dosimetric advantages for lung cancer patients treated with external beam therapy, but is difficult for many patients to perform. Proton therapy permits sparing of the downstream organs at risk (OAR). We compared conventionally fractionated proton (p) and photon(x) plans on both free breathing (FB) and DIBH planning CTs to determine the effect of DIBH with proton therapy.

View Article and Find Full Text PDF

Purpose/objective(s): The additional personnel and imaging procedures required for Adaptive Radiation Therapy (ART) pose a challenge for a broad implementation. We hypothesize that a change in transit fluence during the treatment course is correlated with the change of quality of life and thus can be used as a replanning trigger.

Materials/methods: Twenty-one head and neck cancer (HNC) patients filled out an MD Anderson Dysphagia Inventory (MDADI) questionnaire, before-and-after the radiotherapy treatment course.

View Article and Find Full Text PDF

Purpose: We sought to investigate the tumor control probability (TCP) of spinal metastases treated with stereotactic body radiation therapy (SBRT) in 1 to 5 fractions.

Methods And Materials: PubMed-indexed articles from 1995 to 2018 were eligible for data extraction if they contained SBRT dosimetric details correlated with actuarial 2-year local tumor control rates. Logistic dose-response models of collected data were compared in terms of physical dose and 3-fraction equivalent dose.

View Article and Find Full Text PDF

Purpose: To evaluate two three-dimensional (3D)/3D registration platforms, one two-dimensional (2D)/3D registration method, and one 3D surface registration method (3DS). These three technologies are available to perform six-dimensional (6D) registrations for image-guided radiotherapy treatment.

Methods: Fiducial markers were asymmetrically placed on the surfaces of an anthropomorphic head phantom (n = 13) and a body phantom (n = 8), respectively.

View Article and Find Full Text PDF

Purpose: To design a convolutional recurrent neural network (CRNN) that calculates three-dimensional (3D) positions of lung tumors from continuously acquired cone beam computed tomography (CBCT) projections, and facilitates the sorting and reconstruction of 4D-CBCT images.

Method: Under an IRB-approved clinical lung protocol, kilovoltage (kV) projections of the setup CBCT were collected in free-breathing. Concurrently, an electromagnetic signal-guided system recorded motion traces of three transponders implanted in or near the tumor.

View Article and Find Full Text PDF

Spine stereotactic body radiation therapy frequently involves the delivery of high doses to targets in proximity to the spinal cord; thus, the radiation must be delivered with great spatial accuracy. Monitoring for large shifts in target and cord position that might occur during dose delivery is a challenge for clinics equipped with a conventional C-arm Linac. Treatment must be halted, then imaging and registration must be done to determine whether a significant shift has occurred.

View Article and Find Full Text PDF

Metallic objects, such as dental fillings, cause artifacts in computed tomography (CT) scans. We quantify the contouring and dosimetric effects of Orthopedic Metal Artifact Reduction (O-MAR), in head and neck radiotherapy. The ease of organ contouring was assessed by having a radiation oncologist identify the CT data set with or without O-MAR for each of 28 patients that was easier to contour.

View Article and Find Full Text PDF

Purpose: Localizing lung tumors during treatment delivery is critical for managing respiratory motion, ensuring tumor coverage, and reducing toxicities. The purpose of this project is to develop a real-time system that performs markerless tracking of lung tumors using simultaneously acquired MV and kV images during radiotherapy of lung cancer with volumetric modulated arc therapy.

Method: Continuous MV/kV images were simultaneously acquired during dose delivery.

View Article and Find Full Text PDF

Introduction: Often in clinical practice radiation oncologists encounter patients who require treatment to the spine commonly in the setting of metastatic disease. These metastases usually cause pain, immobility, or neurologic deficits mandating expedited therapy to alleviate the suffering of our patients. Spine radiosurgery techniques have been used extensively for palliation purposes; however, given the patients' deteriorating condition or pain and inability to tolerate anesthesia the radiation oncologist is often left with the conundrum of how to best set up his or her patient in preparation for radiosurgery if supine is not a viable option.

View Article and Find Full Text PDF

Objective: Dose-volume tolerance of the spinal cord (SC) in spinal stereotactic radiosurgery (SRS) is difficult to define because radiation myelitis rates are low, and published reports document cases of myelopathy but do not account for the total number of patients treated at given dose-volume combinations who do not have myelitis. This study reports SC toxicity from single-fraction spinal SRS and presents a comprehensive atlas of the incidence of adverse events to examine dose-volume predictors.

Methods And Materials: A prospective database of all patients undergoing single-fraction spinal SRS at our institution between 2004 and 2011 was reviewed.

View Article and Find Full Text PDF

OBJECTIVE The aim of this study was to evaluate the safety and efficacy of kyphoplasty treatment prior to spine stereotactic radiosurgery (SRS) in patients with spine metastases. METHODS A retrospective review of charts, radiology reports, and images was performed for all patients who received SRS (single fraction; either standalone or post-kyphoplasty) at a large tertiary cancer center between January 2012 and July 2015. Patient and tumor variables were documented, as well as treatment planning data and dosimetry.

View Article and Find Full Text PDF

OBJECTIVE An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. METHODS All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3-6 months until death.

View Article and Find Full Text PDF

OBJECTIVE Spine radiosurgery is increasingly being used to treat spinal metastases. As patients are living longer because of the increasing efficacy of systemic agents, appropriate follow-up and posttreatment management for these patients is critical. Tumor progression after spine radiosurgery is rare; however, vertebral compression fractures are recognized as a more common posttreatment effect.

View Article and Find Full Text PDF

Purpose: To quantify the relative biological effectiveness (RBE) of the distal edge of the proton Bragg peak, using an in vitro assay of DNA double-strand breaks (DSBs).

Methods And Materials: U2OS cells were irradiated within the plateau of a spread-out Bragg peak and at each millimeter position along the distal edge using a custom slide holder, allowing for simultaneous measurement of physical dose. A reference radiation signal was generated using photons.

View Article and Find Full Text PDF

Purpose: To assess intrafraction respiratory motion using a commercial kilovoltage imaging system for abdominal tumor patients with implanted fiducials and breathing constrained by pneumatic compression during stereotactic body radiation therapy (SBRT).

Methods And Materials: A pneumatic compression belt limited respiratory motion in 19 patients with radiopaque fiducials in or near their tumor during SBRT for abdominal tumors. Kilovoltage images were acquired at 5- to 6-second intervals during treatment using a commercial system.

View Article and Find Full Text PDF

Purpose: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate.

Methods: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min.

View Article and Find Full Text PDF

Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment.

Methods And Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction.

View Article and Find Full Text PDF

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment.

View Article and Find Full Text PDF

Purpose: Abdominal compression using a pneumatic abdominal compression belt developed in-house has been used to reduce respiratory motion of patients undergoing hypo-fractionated or single fraction stereotactic radio-ablative therapy for abdominal cancers. The clinical objective of belt usage was to reduce the cranial-caudal (CC) respiratory motion of the tumor to 5 mm or less during both CT simulation and treatment. A retrospective analysis was done to determine the effectiveness of the device and associated clinical procedures to reduce the CC respiratory motion of the tumor.

View Article and Find Full Text PDF

To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI.

View Article and Find Full Text PDF

Background: En bloc wide-margin excision significantly decreases the risk of chordoma recurrence. However, a wide surgical margin cannot be obtained in many chordomas because they arise primarily in the sacrum, clivus, and mobile spine. Furthermore, these tumors have shown resistance to fractionated photon radiation at conventional doses and numerous chemotherapies.

View Article and Find Full Text PDF