Publications by authors named "Michael Fiederle"

Nuclear power plant decommissioning requires the rapid and accurate classification of radioactive waste in narrow spaces and under time constraints. Photon-counting detector technology offers an effective solution for the quick classification and detection of radioactive hotspots in a decommissioning environment. This paper characterizes a 5 mm CdTe Timepix3 detector and evaluates its feasibility as a single-layer Compton camera.

View Article and Find Full Text PDF

Despite the benefits of mammography investigations, some studies have shown that X-ray exposure from the mammography screening itself can statistically cause breast cancer in a small fraction of women. Therefore, a dose reduction in mammography is desirable. At the same time, there is a demand for a higher spatial resolution in mammographic imaging.

View Article and Find Full Text PDF

The x-ray dark-field contrast accessible via grating interferometry is sensitive to features at length scales well below what is resolvable by a detector system. It is commonly explained as arising from small-angle x-ray scattering (SAXS), and can be implemented both at synchrotron beamlines and with low-brilliance sources such as x-ray tubes. Here, we demonstrate that for tube based setups the underlying process of image formation can be fundamentally different.

View Article and Find Full Text PDF

Radon and thoron as well as their short-lived progenies are decay products of the radium and thorium series decays. They are the most important radionuclide elements with respect to public exposure. To utilize the semiconductor pixel radiation Timepix chip for the measurement of active and real-time alpha particles from radon, thoron and their progenies, it is necessary to check the registration and visualization of the chip.

View Article and Find Full Text PDF

The dark-field image obtained in grating-based x-ray phase-contrast imaging can provide information about the objects' microstructures on a scale smaller than the pixel size even with low geometric magnification. In this publication we demonstrate that the dark-field image quality can be enhanced with an energy-resolving pixel detector. Energy-resolved x-ray dark-field images were acquired with a 16-energy-channel photon-counting pixel detector with a 1 mm thick CdTe sensor in a Talbot-Lau x-ray interferometer.

View Article and Find Full Text PDF

Spectroscopic x-ray imaging based on pixellated semiconductor detectors can be sensitive to charge sharing and K-fluorescence, depending on the sensor material used, its thickness and the pixel pitch employed. As a consequence, spectroscopic resolution is partially lost. In this paper, we study a new detector ASIC, the Medipix3RX, that offers a novel feature called charge summing, which is established by making adjacent pixels communicate with each other.

View Article and Find Full Text PDF

High resistivity gallium arsenide is considered a suitable sensor material for spectroscopic X-ray imaging detectors. These sensors typically have thicknesses between a few hundred μm and 1 mm to ensure a high photon detection efficiency. However, for small pixel sizes down to several tens of μm, an effect called charge sharing reduces a detector's spectroscopic performance.

View Article and Find Full Text PDF

Purpose: Pulse pileup occurring at high x-ray fluxes can severely degrade the energy resolution provided by a photon counting detector, which can represent a problem in spectroscopic CT when performing quantitative material discrimination tasks. As the effects of pileup can be most easily seen as a degradation of a detector's count rate linearity at high fluxes, it has been proposed previously to quantify and correct these nonlinearities. While this strategy has been applied successfully to materials without K-edges, it is currently unknown if this still prevails when using medical contrast agents.

View Article and Find Full Text PDF

The performance of a recently developed full-field X-ray micro-imaging system based on an in-line Bragg magnifier is reported. The system is composed of quasi-channel-cut crystals in combination with a Medipix single-photon-counting detector. A theoretical and experimental study of the imaging performance of the crystals-detector combination and a comparison with a standard indirect detector typically used in high-resolution X-ray imaging schemes are reported.

View Article and Find Full Text PDF

Spectroscopic x-ray imaging by means of photon counting detectors has received growing interest during the past years. Critical to the image quality of such devices is their pixel pitch and the sensor material employed. This paper describes the imaging properties of Medipix2 MXR multi-chip assemblies bump bonded to 1 mm thick CdTe sensors.

View Article and Find Full Text PDF

In this work an X-ray imaging system based on a recently developed in-line two-dimensional Bragg magnifier composed of two monolithic V-shaped crystals made of dislocation-free germanium is presented. The channel-cut crystals were used in one-dimensional and in two-dimensional (crossed) configurations in imaging applications and allowed measurement of phase-contrast radiograms both in the edge-enhanced and in the holographic regimes. The measurement of the phase gradient in two orthogonal directions is demonstrated.

View Article and Find Full Text PDF