Neurochemical sensing with implantable devices has gained remarkable attention over the last few decades. A promising area of this research is the progress of novel electrodes as electrochemical tools for neurotransmitter detection in the brain. The boron-doped diamond (BDD) electrode is one such candidate that previously has been reported for its excellent electrochemical properties, including a wide working potential, superior chemical inertness and mechanical stability, good biocompatibility and resistance to fouling.
View Article and Find Full Text PDFFast-scan cyclic voltammetry (FSCV) is an electrochemical sensing technique that can be used for neurochemical sensing with high spatiotemporal resolution. Carbon fiber microelectrodes (CFMEs) are traditionally used as FSCV sensors. However, CFMEs are prone to electrochemical fouling caused by oxidative byproducts of repeated serotonin (5-HT) exposure, which makes them less suitable as chronic 5-HT sensors.
View Article and Find Full Text PDFNeurotransmitter release is important to study in order to better understand neurological diseases and treatment approaches. Serotonin is a neurotransmitter known to play key roles in the etiology of neuropsychiatric disorders. Fast-scan cyclic voltammetry (FSCV) has enabled the detection of neurochemicals, including serotonin, on a sub-second timescale via the well-established carbon fiber microelectrode (CFME).
View Article and Find Full Text PDFMicromachines (Basel)
January 2021
J Phys Condens Matter
February 2020
A quantitative criterion for predicting the onset of disordering during high strain rate deformation is defined that is based on the potential energy (PE) per atom (PE/atom). The criterion is a necessary, but not sufficient condition to predict disorder. The stress state and loading direction of the crystal must allow deviatoric displacements that can induce disordering and the strain rate must be sufficiently high.
View Article and Find Full Text PDFDiamond possesses many favorable properties for biochemical sensors, including biocompatibility, chemical inertness, resistance to biofouling, an extremely wide potential window, and low double-layer capacitance. The hardness of diamond, however, has hindered its applications in neural implants due to the mechanical property mismatch between diamond and soft nervous tissues. Here, we present a flexible, diamond-based microelectrode probe consisting of multichannel boron-doped polycrystalline diamond (BDD) microelectrodes on a soft Parylene C substrate.
View Article and Find Full Text PDFACS Appl Mater Interfaces
May 2019
The combination of conductivity, optical transparency, and wide anodic potential window has driven significant interest in indium tin oxide (ITO) as an electrode material for electrochemical measurements. More recently, ITO has been applied to the detection of trace metals using cathodic stripping voltammetry (CSV), specifically manganese (Mn). However, the optimization of ITO fabrication for a voltammetric method such as CSV is yet to be reported, nor have the microstructural properties of ITO been investigated for CSV.
View Article and Find Full Text PDFBoron-doped diamond (BDD) is a promising electrochemical tool that exhibits excellent chemical sensitivity and stability. These intrinsic advantages coupled with the material's vast microfabrication flexibility make BDD an attractive sensing device. In this study, two different 3-in-1 BDD electrode sensors were fabricated, characterized, and investigated for their capability to detect isatin, an anxiogenic indole that possesses anticonvulsant activity.
View Article and Find Full Text PDFBoron-doped diamond (BDD) has superior electrochemical properties for bioelectronic systems. However, due to its high synthesis temperature, traditional microfabrication methods have limits to integrating BDD with emerging classes of flexible, polymer-based bioelectronic systems. This paper introduces a novel fabrication solution to this challenge, which features (i) a wafer-scale substrate transfer process with all diamond structures transferred onto a flexible Parylene-C substrate and (ii) Parylene anchors introduced to strengthen the bonding between BDD and Parylene substrates, as demonstrated by a peeling test.
View Article and Find Full Text PDFReversible assembly of plasmonic nanoparticles can be used to modulate their structural, electrical, and optical properties. Common and versatile tools in nanoparticle manipulation and assembly are optical tweezers, but these require tightly focused and high-power (10-100 mW/μm) laser beams with precise optical alignment, which significantly hinders their applications. Here we present light-directed reversible assembly of plasmonic nanoparticles with a power intensity below 0.
View Article and Find Full Text PDFDesigning near-field computer-generated holograms (CGHs) for a spatial light modulator (SLM) requires backward diffraction calculations. However, direct implementation of the discrete computational model of the Fresnel diffraction integral often produces inaccurate reconstruction. Finite sizes of the SLM and the target image, as well as aliasing, are major sources of error.
View Article and Find Full Text PDFA normal-incident flattop laser with a tapered end is proposed as an optical undulator to achieve a high-gain and high-brightness X-ray free electron laser (FEL). The synchronic interaction of an electron bunch with the normal incident laser is realized by tilting the laser pulse front. The intensity of the flattop laser is kept constant during the interaction time of the electron bunch and the laser along the focal plane of a cylindrical lens.
View Article and Find Full Text PDFA series of Boron-Doped Diamond (BDD) ultramicroelectrode arrays were fabricated and investigated for their performance as electrochemical sensors to detect trace level metals such as cadmium. The steady-state diffusion behavior of these sensors was validated using cyclic voltammetry followed by electrochemical detection of cadmium in water and in human urine to demonstrate high sensitivity (>200 μA ppb(-1) cm(-2)) and low background current (<4 nA). When an array of ultramicroelectrodes was positioned with optimal spacing, these BDD sensors showed a sigmoidal diffusion behavior.
View Article and Find Full Text PDFPhase compression is used to suppress the on-axis zero-order diffracted (ZOD) beam from a pixelated phase-only spatial light modulator (SLM) by a simple modification to the computer generated hologram (CGH) loaded onto the SLM. After CGH design, the phase of each SLM element is identically compressed by multiplying by a constant scale factor and rotated on the complex unit-circle to produce a cancellation beam that destructively interferes with the ZOD beam. Experiments achieved a factor of 3 reduction of the ZOD beam using two different liquid-crystal SLMs.
View Article and Find Full Text PDFWe have achieved high-precision laser beam shaping by using a binary-amplitude spatial light modulator, a digital micromirror device (DMD), followed by an imaging telescope that contains a pinhole low-pass filter (LPF). An error diffusion algorithm was used to design the initial DMD pixel pattern based on the measured input beam profile. This pattern was iteratively refined by simulating the optically low-pass filtered DMD image and changing DMD pixels to lift valleys and suppress peaks.
View Article and Find Full Text PDFWe demonstrate a digital micromirror device (DMD)-based optical system that converts a spatially noisy quasi-Gaussian to an eighth-order super-Lorentzian flat-top beam. We use an error-diffusion algorithm to design the binary pattern for the Texas Instruments DLP device. Following the DMD, a telescope with a pinhole low-pass filters the beam and scales it to the desired sized image.
View Article and Find Full Text PDFSchweiz Monatsschr Zahnmed
October 2007
Infrequent training of artificial ventilation in dental facilities implies poor performance of this procedure under CPR. Gastric inflation is a significant issue when ventilation is performed on an unprotected airway. An Easy Grip (EG) Bag-Valve-Mask Resuscitator, a Laryngeal Tube (LT), size #5, and a SMART BAG (SB) resuscitator, a pressure-limiting device, were tested to assess the respiratory effects especially focussing on prevention of gastric inflation during simulated CPR.
View Article and Find Full Text PDFNonuniformity in the thickness of thin films can severely distort their transmission spectra as compared with those of flat, smooth films. Methods that extract properties such as refractive index, thickness, and extinction coefficient of such films can suffer inaccuracies when they are applied to wedged or nonuniformly thick films. To accurately extract optical properties of nonuniform films, we have developed a novel numerical method and efficient constitutive relations that can determine film properties from just the transmission spectrum for films that are locally smooth with negligible scattering loss.
View Article and Find Full Text PDFThe optical cross correlation of an image with another image that was spatial-frequency shifted in one dimension was demonstrated in a photorefractive VanderLugt correlator. The first image was stored as a Fourier-transform hologram in a photorefractive Bi12SiO20 crystal (BSO) and was successively correlated with different spatial-frequency-shifted versions of a second image. We implemented the spatial-frequency shift by rotating a galvanometer mirror in an image plane, causing the Fourier transform to be shifted laterally in the BSO.
View Article and Find Full Text PDF