Publications by authors named "Michael E Gehm"

Spatial aperture coding is a technique used to improve throughput without sacrificing resolution both in optical spectroscopy and sector mass spectrometry (MS). Previous work demonstrated that aperture coding combined with a position-sensitive array detector in a miniature cycloidal mass spectrometer was successful in providing high-throughput, high-resolution measurements. However, due to poor alignment and field nonuniformities, reconstruction artifacts were present.

View Article and Find Full Text PDF

Rationale: Higher resolution in fieldable mass spectrometers (MS) is desirable in space flight applications to enable resolving isobaric interferences at m/z < 60 u. Resolution in portable cycloidal MS coupled with array detectors could be improved by reducing the slit width and/or by reducing the width of the detector pixels. However, these solutions are expensive and can result in reduced sensitivity.

View Article and Find Full Text PDF

With the advent of technologies such as ion array detectors and high energy permanent magnet materials, there is renewed interest in the unique focusing properties of the cycloidal mass analyzer and its ability to enable small, high-resolution, and high-sensitivity instruments. However, most literature dealing with the design of cycloidal mass analyzers assumes a single channel detector because at the time of those publications, compatible multichannel detectors were not available. This manuscript introduces and discusses considerations and a procedure for designing cycloidal mass analyzers coupled with focal plane ion array detectors.

View Article and Find Full Text PDF

In 1938, Walker Bleakney and John A. Hipple first described the cycloidal mass analyzer as the only mass analyzer configuration capable of "perfect" ion focusing. Why has their geometry been largely neglected for many years and how might it earn a respectable place in the world of modern chemical analysis? This Perspective explores the properties of the cycloidal mass analyzer and identifies the lack of suitable ion array detectors as a significant reason why cycloidal mass analyzers are not widely used.

View Article and Find Full Text PDF

Cycloidal sector mass analyzers have, in principle, perfect focusing due to perpendicularly oriented uniform electric and magnetic fields, making them ideal candidates for incorporation of spatially coded apertures. We have previously demonstrated a proof-of-concept cycloidal-coded aperture miniature mass spectrometer (C-CAMMS) instrument and achieved a greater than 10-fold increase in throughput without sacrificing resolution, compared with a single slit instrument. However, artifacts were observed in the reconstructed mass spectrum due to nonuniformity in the electric field and misalignment of the detector and the ion source with the mass analyzer focal plane.

View Article and Find Full Text PDF

Anthropomorphic breast phantoms mimic patient anatomy in order to evaluate clinical mammography and digital breast tomosynthesis system performance. Our goal is to create a modular phantom with an anthropomorphic region to allow for improved lesion and calcification detection as well as a uniform region to evaluate standard quality control (QC) metrics. Previous versions of this phantom used commercial photopolymer inkjet three-dimensional printers to recreate breast anatomy using four surfaces that were fabricated with commercial materials spanning only a limited breast density range of 36% to 64%.

View Article and Find Full Text PDF

Photoelastic modulator-based polarimeters use multi-carrier modulation schemes that are more complicated than the single carriers of rotating optics. Current state-of-the-art reconstruction implementations favor mathematical simplicity by using significantly abridged subsets of channels. In this Letter, we extend our generalized channeled polarimetry principles to address the challenges associated with multi-carrier modulation schemes.

View Article and Find Full Text PDF

Imaging through opaque scattering media is critically important in applications ranging from biological and astronomical imaging to metrology and security. While the random process of scattering in turbid media produces scattered light that appears uninformative to the human eye, a wealth of information is contained in the signal and can be recovered using computational post-processing techniques. Recent studies have shown that statistical correlations present in the scattered light, known as 'memory effects', allow for diffraction-limited imaging through opaque media without detailed knowledge of (or access to) the source or scatterer.

View Article and Find Full Text PDF

Cycloidal mass analyzers are unique sector mass analyzers as they exhibit perfect double focusing, making them ideal for incorporating spatial aperture coding, which can increase the throughput of a mass analyzer without affecting the resolving power. However, the focusing properties of the cycloidal mass analyzer depend on the uniformity of the electric and magnetic fields. In this paper, finite element simulation and charged particle tracing were used to investigate the effect of field uniformity on imaging performance of a cycloidal mass analyzer.

View Article and Find Full Text PDF

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time.

View Article and Find Full Text PDF

The use of coded apertures in mass spectrometry can break the trade-off between throughput and resolution that has historically plagued conventional instruments. Despite their very early stage of development, coded apertures have been shown to increase throughput by more than one order of magnitude, with no loss in resolution in a simple 90-degree magnetic sector. This enhanced throughput can increase the signal level with respect to the underlying noise, thereby significantly improving sensitivity to low concentrations of analyte.

View Article and Find Full Text PDF

Spectral imaging is a powerful tool for providing in situ material classification across a spatial scene. Typically, spectral imaging analyses are interested in classification, though often the classification is performed only after reconstruction of the spectral datacube. We present a computational spectral imaging system, the Adaptive Feature-Specific Spectral Imaging Classifier (AFSSI-C), which yields direct classification across the spatial scene without reconstruction of the source datacube.

View Article and Find Full Text PDF

In order to minimize losses in signal intensity often present in mass spectrometry miniaturization efforts, we recently applied the principles of spatially coded apertures to magnetic sector mass spectrometry, thereby achieving increases in signal intensity of greater than 10× with no loss in mass resolution Chen et al. (J. Am.

View Article and Find Full Text PDF

Miniaturizing instruments for spectroscopic applications requires the designer to confront a tradeoff between instrument resolution and instrument throughput [and associated signal-to-background-ratio (SBR)]. This work demonstrates a solution to this tradeoff in sector mass spectrometry by the first application of one-dimensional (1D) spatially coded apertures, similar to those previously demonstrated in optics. This was accomplished by replacing the input slit of a simple 90° magnetic sector mass spectrometer with a specifically designed coded aperture, deriving the corresponding forward mathematical model and spectral reconstruction algorithm, and then utilizing the resulting system to measure and reconstruct the mass spectra of argon, acetone, and ethanol.

View Article and Find Full Text PDF

In mass spectrometer design, there has been a historic belief that there exists a fundamental trade-off between instrument size, throughput, and resolution. When miniaturizing a traditional system, performance loss in either resolution or throughput would be expected. However, in optical spectroscopy, both one-dimensional (1D) and two-dimensional (2D) aperture coding have been used for many years to break a similar trade-off.

View Article and Find Full Text PDF

Computer-generated volume holograms (CGVHs) are gradient refractive index (GRIN) devices that consist of a superposition of multiple periodic diffraction gratings. Fabrication of these components for the visible range is difficult due to the small length-scale requirements but is more tenable in the terahertz (THz), as the length scales become more practical (≥ 10 m). We successfully utilized polymer-based 3D additive rapid-prototyping technology to fabricate, to our knowledge, the world's first 3D THz CGVH in approximately 50 minutes, using $12 of consumables.

View Article and Find Full Text PDF

The 2012 Computational Optical Sensing and Imaging (COSI) conference of the Optical Society of America was one of six colocated meetings composing the Imaging and Applied Optics Congress held in Monterey, California, 24-28 June. COSI, together with the Imaging Systems and Applications, Optical Sensors, Applied Industrial Optics, and Optical Remote Sensing of the Environment conferences, brought together a diverse group of scientists and engineers sharing a common interest in measuring and processing of information carried by optical fields. This special feature includes several papers based on presentations given at the 2012 COSI conference as well as independent contributions, which together highlight several important trends.

View Article and Find Full Text PDF

An all-dielectric THz waveguide has been designed, fabricated and characterized. The design is based on a hollow-core electromagnetic crystal waveguide, and the fabrication is implemented via polymer-jetting rapid prototyping. Measurements of the waveguide power loss factor show good agreement with simulation.

View Article and Find Full Text PDF

Advances in 3D rapid-prototyping printers, 3D modeling software, and casting techniques allow for the fabrication of cost-effective, custom components in gamma-ray and x-ray imaging systems. Applications extend to new fabrication methods for custom collimators, pinholes, calibration and resolution phantoms, mounting and shielding components, and imaging apertures. Details of the fabrication process for these components are presented, specifically the 3D printing process, cold casting with a tungsten epoxy, and lost-wax casting in platinum.

View Article and Find Full Text PDF

We experimentally evaluate diverse static independent column codes in a coded aperture spectrometer. The performance of each code is evaluated based on the signal-to-noise ratio (SNR), defined as the peak value in the spectrum to the standard deviation of the background noise, as a function of subpixel vertical misalignments. Among the code families tested, an S-matrix-based code produces spectral reconstructions with the highest SNR.

View Article and Find Full Text PDF

We propose a new class of aperture-coded spectrometer that is optimized for the spectral characterization of diffuse sources. The instrument achieves high throughput and high spectral resolution by replacing the slit of conventional dispersive spectrometers with a more complicated spatial filter. We develop a general mathematical framework for deriving the required aperture codes and discuss several appealing code families.

View Article and Find Full Text PDF