Publications by authors named "Michael D Eggen"

In the present work, the contribution of lipid peroxidation on modifications of lysine and arginine residues of proteins was investigated. Lipid peroxidation had a major impact on malondialdehyde-derived protein modifications; however, the influence on glyoxal and methylglyoxal-derived modifications in flat wafers was negligible. Therefore, vegetable oils (either linseed oil, sunflower oil, or coconut oil) were added to respective batters, and flat wafers were baked (150 °C, 3-10 min).

View Article and Find Full Text PDF

The reaction of the -amino group of lysine residues and 1,2-dicarbonyl compounds during Maillard processes leads to advanced glycation end products (AGEs). In the present work, we deliver a comprehensive analysis of changes of carbohydrates, dicarbonyl structures, and 11 AGEs during the grilling of porcine meat patties. While raw meat contained mainly glyoxal-derived -carboxymethyl lysine (CML), grilling led to an increase of predominantly methylglyoxal-derived AGEs -carboxyethyl lysine (CEL), -lactoyl lysine, methylglyoxal lysine dimer (MOLD), and methylglyoxal lysine amide (MOLA).

View Article and Find Full Text PDF

One crucial aspect of the Maillard reaction is the formation of reactive α-dicarbonyl structures like glyoxal, which are prone toward further reactions with proteins, e.g., the -amino group of lysine.

View Article and Find Full Text PDF

Background: Medtronic is developing an atrial Micra Transcatheter Pacing System (Medtronic, Minneapolis, Minnesota) and associated retrieval system.

Objective: The purpose of this study was to evaluate chronic atrial Micra retrieval, reimplantation, and chronic pacing performance.

Methods: Sheep were implanted in 2 groups: group 1 (n = 6) for 6 months, a second device implanted, and first retrieved and studied for an additional 6 months; group 2 (n = 6) for 6 months, devices were retrieved, and a second device implanted and observed acutely.

View Article and Find Full Text PDF

Background: The introduction of transcatheter pacemaker technology has the potential to significantly reduce if not eliminate a number of complications associated with a traditional leaded pacing system. However, this technology raises new questions regarding how to manage the device at end of service, the number of devices the right ventricle (RV) can accommodate, and what patient age is appropriate for this therapy. In this study, six human cadaver hearts and one reanimated human heart (not deemed viable for transplant) were each implanted with three Micra devices in traditional pacing locations via fluoroscopic imaging.

View Article and Find Full Text PDF

Goal: The purpose of this paper was to evaluate a nitinol tine fixation design for a transcatheter pacemaker in order to determine if the tines could be easily deployed and safely removed from the myocardium, enable low, stable pacing thresholds, and minimize the potential for dislodgment.

Methods: The penetration properties of 13 human hearts were compared to the deployment and fixation energy of the tines to determine if the tines could be easily deployed and removed from the myocardium. The safety factor for dislodgement was calculated by comparing the kinetic energy of the device to the fixation energy of the tines.

View Article and Find Full Text PDF

This paper describes how the Atlas of Human Cardiac Anatomy website can be used to improve cardiac device design throughout the process of development. The Atlas is a free-access website featuring novel images of both functional and fixed human cardiac anatomy from over 250 human heart specimens. This website provides numerous educational tutorials on anatomy, physiology and various imaging modalities.

View Article and Find Full Text PDF

Within the adult population living with congenital heart defects, approximately 20 % have an atrial septal defect, which suggests that only 0.4-0.05 % of the entire adult population has an atrial septal defect (ASD).

View Article and Find Full Text PDF

The three-dimensional cardiac electrical imaging (3DCEI) technique was previously developed to estimate the initiation site(s) of cardiac activation and activation sequence from the noninvasively measured body surface potential maps (BSPMs). The aim of this study was to develop and evaluate the capability of 3DCEI in mapping the transmural distribution of extracellular potentials and localizing initiation sites of ventricular activation in an in vivo animal model. A control swine model (n = 10) was employed in this study.

View Article and Find Full Text PDF

Recently, diffusion tensor MRI has been utilized as a tool to reconstruct, with high resolution, the three-dimensional myofiber orientation of hearts ex vivo. However, because of limited availability of human hearts, it is common to recover specimens postmortem, after some degree of decomposition has occurred. In this study, we describe the ability to reconstruct local fiber orientation within a unique set of human hearts using diffusion tensor MRI; relative effects of specimen decomposition were also assessed.

View Article and Find Full Text PDF

Localization of the source of cardiac ectopic activity has direct clinical benefits for determining the location of the corresponding ectopic focus. In this study, a recently developed current-density (CD)-based localization approach was experimentally evaluated in noninvasively localizing the origin of the cardiac ectopic activity from body-surface potential maps (BSPMs) in a well-controlled experimental setting. The cardiac ectopic activities were induced in four well-controlled intact pigs by single-site pacing at various sites within the left ventricle (LV).

View Article and Find Full Text PDF

Localization of the initial site of cardiac ectopic activity has direct clinical benefits for treating focal cardiac arrhythmias. The aim of the present study is to experimentally evaluate the performance of the equivalent moving dipole technique on noninvasively localizing the origin of the cardiac ectopic activity from the recorded body surface potential mapping (BSPM) data in a well-controlled experimental setting. The cardiac ectopic activities were induced in four well-controlled intact pigs by either single-site pacing or dual-site pacing within the ventricles.

View Article and Find Full Text PDF

This study demonstrates the capabilities of MRI in the assessment of cardiac pacing induced ventricular dyssynchrony, and the findings support the need for employing more physiological pacing. A human donor heart deemed non-viable for transplantation, was reanimated using an MR compatible, four-chamber working perfusion system. The heart was imaged using a 1.

View Article and Find Full Text PDF

The accuracy of localizing the initiation site of cardiac activation by noninvasively estimating a single moving dipole (SMD) was investigated in a swine model. Body surface potential mapping (BSPM) and intracavitary noncontact mapping (NCM) were performed simultaneously during acute left ventricular (LV) endocardial pacing. For each animal, the boundary element model was constructed from preoperative magnetic resonance images (MRI).

View Article and Find Full Text PDF