The Brain Tumor Segmentation (BraTS) Challenge has been a main driver of the development of deep learning (DL) algorithms and provides by far the largest publicly available expert-annotated brain tumour dataset but contains solely preoperative examinations. The aim of our study was to facilitate the use of the BraTS dataset for training DL brain tumour segmentation algorithms for a postoperative setting. To this end, we introduced an automatic conversion of the three-label BraTS annotation protocol to a two-label annotation protocol suitable for postoperative brain tumour segmentation.
View Article and Find Full Text PDFDiagnostics (Basel)
August 2024
Assessing a woman's risk of breast cancer is important for personalized screening. Mammographic density is a strong risk factor for breast cancer, but parenchymal texture patterns offer additional information which cannot be captured by density. We aimed to combine BI-RADS density score 4th Edition and a deep-learning-based texture score to stratify women in screening and compare rates among the combinations.
View Article and Find Full Text PDFJ Med Screen
July 2024
Objective: To assess performance endpoints of a combination of digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) compared with FFDM only in breast cancer screening.
Materials And Methods: This was a prospective population-based screening study, including eligible (50-69 years) women attending the Capital Region Mammography Screening Program in Denmark. All attending women were offered FFDM.
IEEE Trans Ultrason Ferroelectr Freq Control
August 2024
Super-resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared with several minutes in ultrasound localization microscopy (ULM) using MBs.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2024
A new approach for vascular super-resolution (SR) imaging using the erythrocytes as targets (SUper-Resolution ultrasound imaging of Erythrocytes (SURE) imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index (MI) for ultrasound scanning for an increased penetration depth. A synthetic aperture (SA) ultrasound sequence was employed with 12 virtual sources (VSs) using a 10-MHz GE L8-18i-D linear array hockey stick probe.
View Article and Find Full Text PDFSeveral prognostic factors are known to influence survival for patients treated with IDH-wildtype glioblastoma, but unknown factors may remain. We aimed to investigate the prognostic implications of early postoperative MRI findings. A total of 187 glioblastoma patients treated with standard therapy were consecutively included.
View Article and Find Full Text PDFSimulation-based training (SBT) is increasingly acknowledged worldwide and has become a popular tool for ultrasound education. Ultrasound simulation involves the use of technology and software to create a virtual training setting. Simulation-based training allows healthcare professionals to learn, practice, and improve their ultrasound imaging skills in a safe learning-based environment.
View Article and Find Full Text PDFDWI/FLAIR mismatch assessment for ischemic stroke patients shows promising results in determining if patients are eligible for recombinant tissue-type plasminogen activator (r-tPA) treatment. However, the mismatch criteria suffer from two major issues: binary classification of a non-binary problem and the subjectiveness of the assessor. In this article, we present a simple automatic method for segmenting stroke-related parenchymal hyperintensities on FLAIR, allowing for an automatic and continuous DWI/FLAIR mismatch assessment.
View Article and Find Full Text PDFIndividuals with diabetes at risk of developing diabetic kidney disease (DKD) are challenging to identify using currently available clinical methods. Prognostic accuracy and initiation of treatment could be improved by a quantification of the renal microvascular rarefaction and the increased vascular tortuosity during the development of DKD. Super-resolution ultrasound (SRUS) imaging is an in vivo technique capable of visualizing blood vessels at sizes below 75 µm.
View Article and Find Full Text PDFSimulation has been shown to improve clinical learning outcomes, speed up the learning process, and improve trainee confidence, while taking the pressure off initial face-to-face patient clinical areas. The second part of The World Federation for Ultrasound in Medicine and Biology state-of-the-art paper on the use of simulators provides a general approach on the practical implementation. The importance of needs assessment before developing a simulation-based training program is outlined.
View Article and Find Full Text PDFWe conducted this Systematic Review to create an overview of the currently existing Artificial Intelligence (AI) methods for Magnetic Resonance Diffusion-Weighted Imaging (DWI)/Fluid-Attenuated Inversion Recovery (FLAIR)-mismatch assessment and to determine how well DWI/FLAIR mismatch algorithms perform compared to domain experts. We searched PubMed Medline, Ovid Embase, Scopus, Web of Science, Cochrane, and IEEE Xplore literature databases for relevant studies published between 1 January 2017 and 20 November 2022, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We assessed the included studies using the Quality Assessment of Diagnostic Accuracy Studies 2 tool.
View Article and Find Full Text PDFA chest X-ray report is a communicative tool and can be used as data for developing artificial intelligence-based decision support systems. For both, consistent understanding and labeling is important. Our aim was to investigate how readers would comprehend and annotate 200 chest X-ray reports.
View Article and Find Full Text PDFAn early postoperative MRI is recommended following Glioblastoma surgery. This retrospective, observational study aimed to investigate the timing of an early postoperative MRI among 311 patients. The patterns of the contrast enhancement (thin linear, thick linear, nodular, and diffuse) and time from surgery to the early postoperative MRI were recorded.
View Article and Find Full Text PDFIn the context of brain tumour response assessment, deep learning-based three-dimensional (3D) tumour segmentation has shown potential to enter the routine radiological workflow. The purpose of the present study was to perform an external evaluation of a state-of-the-art deep learning 3D brain tumour segmentation algorithm (HD-GLIO) on an independent cohort of consecutive, post-operative patients. For 66 consecutive magnetic resonance imaging examinations, we compared delineations of contrast-enhancing (CE) tumour lesions and non-enhancing T2/FLAIR hyperintense abnormality (NE) lesions by the HD-GLIO algorithm and radiologists using Dice similarity coefficients (Dice).
View Article and Find Full Text PDFIntermetatarsal bursitis (IMB) is an inflammation of the intermetatarsal bursas. The condition causes forefoot pain with symptoms similar to those of Morton's neuroma (MN). Some studies suggest that IMB is a contributing factor to the development of MN, while others describe the condition as a differential diagnosis.
View Article and Find Full Text PDFSimulation has been shown to improve clinical learning outcomes, speed up the learning process and improve learner confidence, whilst initially taking pressure off busy clinical lists. The World Federation for Ultrasound in Medicine and Biology (WFUMB) state of the art paper on the use of simulators in ultrasound education introduces ultrasound simulation, its advantages and challenges. It describes different simulator types, including low and high-fidelity simulators, the requirements and technical aspects of simulators, followed by the clinical applications of ultrasound simulation.
View Article and Find Full Text PDFConsistent annotation of data is a prerequisite for the successful training and testing of artificial intelligence-based decision support systems in radiology. This can be obtained by standardizing terminology when annotating diagnostic images. The purpose of this study was to evaluate the annotation consistency among radiologists when using a novel diagnostic labeling scheme for chest X-rays.
View Article and Find Full Text PDFComput Methods Programs Biomed
November 2022
Background And Objective: population-based finite element analysis of hip joints allows us to understand the effect of inter-subject variability on simulation results. Developing large subject-specific population models is challenging and requires extensive manual effort. Thus, the anatomical representations are often subjected to simplification.
View Article and Find Full Text PDFWe conducted a systematic review of the current status of machine learning (ML) algorithms' ability to identify multiple brain diseases, and we evaluated their applicability for improving existing scan acquisition and interpretation workflows. PubMed Medline, Ovid Embase, Scopus, Web of Science, and IEEE Xplore literature databases were searched for relevant studies published between January 2017 and February 2022. The quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool.
View Article and Find Full Text PDFIntroduction: Comparing imaging examinations with those previously obtained is considered mandatory in imaging guidelines. To our knowledge, no studies are available on neither the influence, nor the sequence, of prior imaging and reports on diagnostic accuracy using biopsy as the reference standard. Such data are important to minimize diagnostic errors and to improve the preparation of diagnostic imaging guidelines.
View Article and Find Full Text PDFDiagnostics (Basel)
July 2022
Obesity is a risk factor of chronic kidney disease (CKD), leading to alterations in the renal vascular structure. This study tested if renal vascular density and tortuosity was quantifiable in vivo in obese rats using microbubble-based super-resolution ultrasound imaging. The kidneys of two 11-week-old and two 20-week-old male obese Zucker rats were compared with age-matched male lean Zucker rats.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2022
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming.
View Article and Find Full Text PDFPrevious studies suggest that the most common cause of spontaneous intracerebral hemorrhage in children and adolescents is arteriovenous malformations (AVMs). However, an update containing recently published data on pediatric spontaneous intracranial hemorrhages is lacking. The aim of this study is to systematically analyze the published data on the etiologies and risk factors of pediatric spontaneous intracranial hemorrhage.
View Article and Find Full Text PDFSuper-resolution ultrasound imaging, based on the localization and tracking of single intravascular microbubbles, makes it possible to map vessels below 100 µm. Microbubble velocities can be estimated as a surrogate for blood velocity, but their clinical potential is unclear. We investigated if a decrease in microbubble velocity in the arterial and venous beds of the renal cortex, outer medulla, and inner medulla was detectable after intravenous administration of the α1-adrenoceptor antagonist prazosin.
View Article and Find Full Text PDF